{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:39:11Z","timestamp":1789000751652,"version":"build-2803163510"},"reference-count":22,"publisher":"S. Karger AG","issue":"3","license":[{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.karger.com\/Services\/SiteLicenses"},{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.karger.com\/Services\/SiteLicenses"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Stereotact Funct Neurosurg"],"published-print":{"date-parts":[[2012]]},"abstract":"<jats:p>&lt;b&gt;&lt;i&gt;Background:&lt;\/i&gt;&lt;\/b&gt; Candidates for deep brain stimulation (DBS) must be carefully evaluated to balance expected benefits with the possibility of serious complications. Several predictive factors exist but are imperfect. &lt;b&gt;&lt;i&gt;Objectives:&lt;\/i&gt;&lt;\/b&gt; The aim of this study was to determine whether linear measurements of the lateral ventricles predict complications following DBS. &lt;b&gt;&lt;i&gt;Methods:&lt;\/i&gt;&lt;\/b&gt; We retrospectively studied a cohort of DBS patients. The primary outcome was postoperative confusion; secondary outcomes were discharge disposition and all in-hospital complications. For each case, a control matched for age, sex, diagnosis, and DBS target was identified. Linear measurements were made from routine preoperative axial MRIs for both cases and controls. &lt;b&gt;&lt;i&gt;Results:&lt;\/i&gt;&lt;\/b&gt; A total of 40 patients met one or more of the end points. Patients with postoperative confusion had a significantly larger minimum width of the lateral ventricles than controls. Patients discharged to a higher level of care and those with any complications also had significantly greater maximum and minimum ventricular widths than controls. &lt;b&gt;&lt;i&gt;Conclusions:&lt;\/i&gt;&lt;\/b&gt; These results suggest that preoperative measurement of the maximum and minimum width of the lateral ventricles may help predict which patients are at risk for complicated recoveries following DBS.<\/jats:p>","DOI":"10.1159\/000338094","type":"journal-article","created":{"date-parts":[[2012,5,7]],"date-time":"2012-05-07T09:14:39Z","timestamp":1336382079000},"page":"167-172","source":"Crossref","is-referenced-by-count":13,"title":["Ventricular Width and Complicated Recovery following Deep Brain Stimulation Surgery"],"prefix":"10.1159","volume":"90","author":[{"given":"Sarah K.","family":"Bourne","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Conrad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter E.","family":"Konrad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph S.","family":"Neimat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas L.","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"127","published-online":{"date-parts":[[2012,5,5]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1056%2FNEJMoa060281"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1001%2Fjama.2008.929"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1212%2F01.wnl.0000260059.77107.c2"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1002%2F1531-8257%28200009%2915%3A5%3C771%3A%3AAID-MDS1003%3E3.0.CO%3B2-Y"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1093%2Fbrain%2Fawf050"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1002%2Fmds.10159"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016%2FS1474-4422%2808%2970291-6"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1056%2FNEJMoa035275"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1159%2F000064600"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1136%2Fjnnp.38.10.948"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1007%2FBF00399698"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1159%2F000028730"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1227%2F01.NEU.0000339173.77240.34"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1227%2FNEU.0b013e318214abda"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.3171%2F2008.12.JNS08885"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1002%2Fmds.23443"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1002%2Fmds.23700"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1002%2Fdmrr.1163"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.3174%2Fajnr.A2018"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.3171%2FJNS-07%2F11%2F0983"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1227%2F01.NEU.0000370597.44524.6D"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1159%2F000108588"}],"container-title":["Stereotactic and Functional Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/338094","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/338094","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T18:16:19Z","timestamp":1745432179000},"score":1,"resource":{"primary":{"URL":"https:\/\/karger.com\/article\/doi\/10.1159\/000338094"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012]]},"references-count":22,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2012,6,1]]},"published-print":{"date-parts":[[2012,6,20]]}},"URL":"https:\/\/doi.org\/10.1159\/000338094","archive":["Portico"],"relation":{},"ISSN":["1011-6125","1423-0372"],"issn-type":[{"value":"1011-6125","type":"print"},{"value":"1423-0372","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012]]}}}