{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T01:34:47Z","timestamp":1773970487940,"version":"3.50.1"},"reference-count":6,"publisher":"S. Karger AG","issue":"3","license":[{"start":{"date-parts":[[2013,10,26]],"date-time":"2013-10-26T00:00:00Z","timestamp":1382745600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/3.0\/"},{"start":{"date-parts":[[2013,10,26]],"date-time":"2013-10-26T00:00:00Z","timestamp":1382745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Case Rep Ophthalmol"],"abstract":"<jats:p>We present the first case of partial aniridia, traumatic cataract, and peripapillary subretinal hemorrhage after blunt trauma to an eye containing a foldable iris-fixated phakic intraocular lens (pIOL). Although the patient experienced visual loss because of considerable corneal astigmatism and a traumatic cataract, vision was recovered by a 2-stage primary corneal repair and cataract surgery with a toric intraocular lens. This case exhibits clinical manifestations that differ from previously reported trauma of a non-foldable iris-fixated pIOL. A relatively small corneal incision and a large optic diameter of Artiflex pIOLs may prevent posttraumatic total expulsion of intraocular tissues and present different clinical features from the case of non-foldable pIOLs (Artisan). Although the extent of the damage is different, the possibility of aniridia and traumatic cataract exists in eyes with both foldable and non-foldable iris-fixated pIOLs.<\/jats:p>","DOI":"10.1159\/000356239","type":"journal-article","created":{"date-parts":[[2013,10,28]],"date-time":"2013-10-28T14:21:24Z","timestamp":1382970084000},"page":"210-215","source":"Crossref","is-referenced-by-count":2,"title":["Traumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation"],"prefix":"10.1159","volume":"4","author":[{"given":"Joo","family":"Hyun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin Kwon","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung Jin","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"127","published-online":{"date-parts":[[2013,10,26]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.06.036"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.07.021"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.12.059"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.03.037"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01026-4"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2001.11"}],"container-title":["Case Reports in Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/356239","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/356239","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T18:16:24Z","timestamp":1745432184000},"score":1,"resource":{"primary":{"URL":"https:\/\/karger.com\/article\/doi\/10.1159\/000356239"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,10,26]]},"references-count":6,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2013,12,1]]}},"URL":"https:\/\/doi.org\/10.1159\/000356239","archive":["Portico"],"relation":{},"ISSN":["1663-2699"],"issn-type":[{"value":"1663-2699","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,10,26]]}}}