{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T12:32:51Z","timestamp":1768825971683,"version":"3.49.0"},"reference-count":14,"publisher":"S. Karger AG","issue":"2","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.karger.com\/Services\/SiteLicenses"},{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.karger.com\/Services\/SiteLicenses"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Stereotact Funct Neurosurg"],"published-print":{"date-parts":[[2020]]},"abstract":"<jats:p>Spinal cord stimulation (SCS) is receiving increasing interests for treating pain and gait disorders in patients with Parkinson\u2019s disease (PD). In an SCS study, it is hard to apply a double-blind approach, especially at low frequencies, as the stimulation normally induces paresthesia which can be perceived by the patient. We herein demonstrate a case treated with SCS in which a blinding design was accomplished by an accidental dislocation of a stimulation lead. A 73-year-old man with PD was admitted to our hospital because of relapsed low back pain. This was due to the dislocation of a previously implanted SCS lead, which caused a decrease in its effectiveness in alleviating pain (from 81 to 43% measured by King\u2019s Parkinson\u2019s Disease Pain Scale) and improving gait (from 35 to 28% measured by the timed up and go test). A second SCS surgery using a paddle lead solved this problem, with improvements in pain and gait rebounded to 81 and 45%. In this case, the paresthesia induced by SCS (using either a paddle lead or percutaneous leads) was below the threshold of perception when the patient was sitting and standing, and a dislocation of one previously implanted percutaneous lead did not cause evident changes in his sensation of paresthesia. At last follow-up, the patient\u2019s quality of life had improved by 40% as measured by the 8-item Parkinson\u2019s Disease questionnaire (PDQ-8). This study could serve partly as a proof that low-frequency SCS is effective in improving pain as well as gait problems in PD patients, which was unlikely a result of a placebo effect.<\/jats:p>","DOI":"10.1159\/000505707","type":"journal-article","created":{"date-parts":[[2020,2,25]],"date-time":"2020-02-25T22:00:34Z","timestamp":1582668034000},"page":"104-109","source":"Crossref","is-referenced-by-count":14,"title":["Spinal Cord Stimulation with Surgical Lead Improves Pain and Gait in Parkinson\u2019s Disease after a Dislocation of Percutaneous Lead: A Case Report"],"prefix":"10.1159","volume":"98","author":[{"given":"Yijie","family":"Lai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yixin","family":"Pan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linbin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chencheng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bomin","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dianyou","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"127","published-online":{"date-parts":[[2020,2,25]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0000000000002353"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.parkreldis.2019.02.044"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s10143-015-0651-1"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1002\/mds.27508"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(14)61393-3"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1002\/mds.26270"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1002\/mds.26850"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuron.2014.08.061"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1002\/mds.27299"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.parkreldis.2011.07.015"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/bs.irn.2017.05.013"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1126\/science.1164901"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1111\/ner.12315"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.parkreldis.2018.07.002"}],"container-title":["Stereotactic and Functional Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/505707","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/505707","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T15:42:15Z","timestamp":1745422935000},"score":1,"resource":{"primary":{"URL":"https:\/\/karger.com\/article\/doi\/10.1159\/000505707"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020]]},"references-count":14,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2020,4,29]]},"published-print":{"date-parts":[[2020,5,4]]}},"URL":"https:\/\/doi.org\/10.1159\/000505707","archive":["Portico"],"relation":{"is-supplemented-by":[{"id-type":"doi","id":"10.6084\/m9.figshare.11897331","asserted-by":"subject"}]},"ISSN":["1011-6125","1423-0372"],"issn-type":[{"value":"1011-6125","type":"print"},{"value":"1423-0372","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020]]}}}