{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T06:08:45Z","timestamp":1781417325030,"version":"3.54.1"},"reference-count":21,"publisher":"S. Karger AG","issue":"1","license":[{"start":{"date-parts":[[2023,8,30]],"date-time":"2023-08-30T00:00:00Z","timestamp":1693353600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/karger.com\/pages\/terms-and-conditions"},{"start":{"date-parts":[[2023,8,30]],"date-time":"2023-08-30T00:00:00Z","timestamp":1693353600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/karger.com\/pages\/terms-and-conditions"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ophthalmologica"],"published-print":{"date-parts":[[2024]]},"abstract":"<jats:p>&lt;b&gt;&lt;i&gt;Introduction:&lt;\/i&gt;&lt;\/b&gt; The aim of this study was to evaluate the outcome of the modified Carlevale intraocular lens (IOL) fixation technique, using two different vitrectomy ports (23- vs. 27-gauge) as anchor fixation. &lt;b&gt;&lt;i&gt;Methods:&lt;\/i&gt;&lt;\/b&gt; Retrospective, consecutive study of 282 eyes (282 patients) who underwent a secondary IOL implantation using the Carlevale IOL (Soleko IOL Division, Italy) with two anchor haptics for intrascleral implantation with either 23- or 27-gauge (G) port. &lt;b&gt;&lt;i&gt;Results:&lt;\/i&gt;&lt;\/b&gt; Transient post-operative ocular hypotonia (intraocular pressure \u22645 mm Hg) was observed less in the 27-G group (13 vs. 4 patients, &lt;i&gt;p&lt;\/i&gt; = 0.057) three requiring additional tunnel sutures (2 cases for 23-G; 1 case 27-G). Post-operative vitreous haemorrhage was recorded more often in the 23-G group (8 vs. 1 patient, &lt;i&gt;p&lt;\/i&gt; = 0.034), but all cases in both groups resolved without intervention. Visual acuity did improve post-operatively in the two groups. No post-operative complications such as retinal detachment, endophthalmitis, and IOL-dislocation tilt were observed in the follow-up. &lt;b&gt;&lt;i&gt;Conclusion:&lt;\/i&gt;&lt;\/b&gt; The 27-G modified technique for sutureless intrascleral implantation is simple and effective and causes less post-operative hypotony. <\/jats:p>","DOI":"10.1159\/000532065","type":"journal-article","created":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T21:03:05Z","timestamp":1697058185000},"page":"1-7","source":"Crossref","is-referenced-by-count":2,"title":["Clinical Experience of Two Sutureless Intrascleral Fixation Techniques for Secondary Intraocular Lens Implantation"],"prefix":"10.1159","volume":"247","author":[{"given":"Kai","family":"Januschowski","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annekatrin","family":"Rickmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl T.","family":"Boden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregor V.","family":"Ehrlich-Treuenst\u00e4tt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Wakili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas","family":"Bisorca-Gassendorf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"127","published-online":{"date-parts":[[2023,8,30]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/805706"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2005.06.010"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/s0161-6420(02)02000-6"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(13)80040-5"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.02.023"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(98)80048-5"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.09.012"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(13)80163-0"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2009.162180"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.11.009"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.03.036"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e32834cd5e5"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1177\/1120672120902020"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000135"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000003220"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1991.36"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1093\/jscr\/rjaa142"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1159\/000485519"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-017-0585-1"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000700"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-020-04789-3"}],"container-title":["Ophthalmologica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/karger.com\/oph\/article-pdf\/247\/1\/1\/4164125\/000532065.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/karger.com\/oph\/article-pdf\/247\/1\/1\/4164125\/000532065.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T15:32:24Z","timestamp":1745422344000},"score":1,"resource":{"primary":{"URL":"https:\/\/karger.com\/article\/doi\/10.1159\/000532065"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,30]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,2,2]]},"published-print":{"date-parts":[[2024,2,14]]}},"URL":"https:\/\/doi.org\/10.1159\/000532065","archive":["Portico"],"relation":{},"ISSN":["0030-3755","1423-0267"],"issn-type":[{"value":"0030-3755","type":"print"},{"value":"1423-0267","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,30]]}}}