{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T18:54:35Z","timestamp":1789757675849,"version":"4.0.1"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"19","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[2002,5,14]]},"abstract":"<jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Background<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            Orthostatic intolerance is characterized by postural tachycardia syndrome (POTS) with exaggerated tachycardia, orthostatic symptoms, and \u201cpooling\u201d (which comprises acrocyanosis and dependent edema when upright). My colleagues and I tested the hypothesis that pooling results from increased venous compliance in POTS patients.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Methods and Results<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            Fifteen patients aged 13 to 19 years were compared with 11 healthy, age-matched controls. The POTS group was divided into patients with high venous pressure (P\n            <jats:sub>v<\/jats:sub>\n            &gt;20 mm Hg) and normal P\n            <jats:sub>v<\/jats:sub>\n            on the basis of resting supine P\n            <jats:sub>v<\/jats:sub>\n            obtained in previous work. Subjects were studied using strain gauge plethysmography to measure blood flow, P\n            <jats:sub>v<\/jats:sub>\n            , and the venous compliance volume-pressure relation while supine and during incremental head-up tilt testing at \u221210\u00b0, 0\u00b0, 20\u00b0, and 35\u00b0. Volume-pressure relations of controls and POTS patients with normal P\n            <jats:sub>v<\/jats:sub>\n            and high P\n            <jats:sub>v<\/jats:sub>\n            were not different and were unchanged by orthostasis. Supine leg peripheral resistance was greater than control resistance in patients with high P\n            <jats:sub>v<\/jats:sub>\n            (54\u00b19 versus 30\u00b16 mm Hg \u00b7 mL\n            <jats:sup>\u22121<\/jats:sup>\n            \u00b7 100 mL\n            <jats:sup>\u22121<\/jats:sup>\n            \u00b7 min\n            <jats:sup>\u22121<\/jats:sup>\n            ) and less than control resistance in patients with normal P\n            <jats:sub>v<\/jats:sub>\n            (17\u00b12 mm Hg \u00b7 mL\n            <jats:sup>\u22121<\/jats:sup>\n            \u00b7 100 mL\n            <jats:sup>\u22121<\/jats:sup>\n            \u00b7 min\n            <jats:sup>\u22121<\/jats:sup>\n            ). On upright tilt, resistance decreased in high P\n            <jats:sub>v<\/jats:sub>\n            to approximate resistance in normal P\n            <jats:sub>v<\/jats:sub>\n            . Resistance in controls increased throughout tilt. Leg P\n            <jats:sub>v<\/jats:sub>\n            increased in patients with normal P\n            <jats:sub>v<\/jats:sub>\n            and in controls but remained unchanged in the high P\n            <jats:sub>v<\/jats:sub>\n            group.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Conclusions<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            The findings suggest that pooling in POTS is due to blunted arterial vasoconstriction, which produces passive redistribution of blood within peripheral venous capacitance beds. Venous compliance in POTS is similar to that in control subjects.\n          <\/jats:p>","DOI":"10.1161\/01.cir.0000016348.55378.c4","type":"journal-article","created":{"date-parts":[[2002,7,28]],"date-time":"2002-07-28T23:16:47Z","timestamp":1027898207000},"page":"2274-2281","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":121,"title":["Pooling in Chronic Orthostatic Intolerance"],"prefix":"10.1161","volume":"105","author":[{"given":"Julian M.","family":"Stewart","sequence":"first","affiliation":[{"name":"From the Department of Pediatrics and Physiology, New York Medical College, Valhalla, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.43.1_Part_1.132"},{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1042\/cs0900277"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02311762"},{"key":"e_1_3_2_4_2","first-page":"S19","volume":"45","year":"1995","journal-title":"Neurology"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2001.90.6.2025"},{"key":"e_1_3_2_6_2","doi-asserted-by":"crossref","unstructured":"Rothe  CF.  Venous system: physiology of the capacitance vessels.In:  Shepherd JT ed.  The Cardiovascular System: Peripheral Circulation and Organ Blood Flow. Handbook of Physiology. Vol III. Bethesda Md:  American Physiologic Society;  1983:  397\u2013452.","DOI":"10.1002\/cphy.cp020313"},{"key":"e_1_3_2_7_2","first-page":"S25","volume":"68","year":"1992","journal-title":"Postgrad Med J"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-7793.1998.611bt.x"},{"key":"e_1_3_2_9_2","unstructured":"Berne  RM Levy  MN.  Textbook of Physiology.  St Louis Mo:  Mosby;  1998."},{"key":"e_1_3_2_10_2","unstructured":"Press  WH.  Numerical Recipes in C.  Cambridge UK:  Cambridge University Press;  1992:  59\u201370."},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1203\/00006450-200008000-00016"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.hyp.10.5.538"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.90.4.7923668"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/PROC.1981.12184"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2001.91.4.1723"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02267785"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2281.1999.00189.x"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1172\/JCI114878"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/res.52.5.6851008"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/res.69.1.2054936"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1994.sp020434"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM200010053431404"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.80.1.2736757"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1997.tb51777.x"},{"key":"e_1_3_2_25_2","first-page":"H674","volume":"259","year":"1990","journal-title":"Am J Physiol"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(96)00051-4"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.93.5.953"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1042\/cs0780101"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1921.sp001964"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1161\/res.24.5.711"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.81.1.2297840"},{"key":"e_1_3_2_32_2","unstructured":"Cannon  WBRA.  Autonomic Neuro-Effector System.  New York NY:  Macmillan;  1937."},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1566-0702(00)00205-8"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-1716.1993.tb09485.x"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1999.87.4.1555"}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.CIR.0000016348.55378.C4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,6]],"date-time":"2024-05-06T18:34:30Z","timestamp":1715020470000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.CIR.0000016348.55378.C4"}},"subtitle":["Arterial Vasoconstrictive but not Venous Compliance Defects"],"short-title":[],"issued":{"date-parts":[[2002,5,14]]},"references-count":35,"journal-issue":{"issue":"19","published-print":{"date-parts":[[2002,5,14]]}},"alternative-id":["10.1161\/01.CIR.0000016348.55378.C4"],"URL":"https:\/\/doi.org\/10.1161\/01.cir.0000016348.55378.c4","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,5,14]]},"assertion":[{"value":"2002-04-22","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}