{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:25:16Z","timestamp":1761611116894},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[2003,9,16]]},"abstract":"<jats:p>\n            <jats:bold>\n              <jats:italic>Background\u2014<\/jats:italic>\n            <\/jats:bold>\n            Parallel imaging by sensitivity encoding (SENSE) may considerably reduce scan time in MRI. For rapid flow quantification in children with congenital heart disease, we evaluated phase-contrast MRI (PC-MRI) techniques combined with SENSE.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Methods and Results\u2014<\/jats:italic>\n            <\/jats:bold>\n            In 22 pediatric patients (mean age, 7.2\u00b16.2 years) with cardiac left-to-right shunt, blood flow rate in the pulmonary artery (Q\n            <jats:sub>p<\/jats:sub>\n            ) and ascending aorta (Q\n            <jats:sub>s<\/jats:sub>\n            ) and flow ratio Q\n            <jats:sub>p<\/jats:sub>\n            \/Q\n            <jats:sub>s<\/jats:sub>\n            were determined by PC-MRI with SENSE reduction-factor 2 and 3 (SF-2 and SF-3). Additionally, we used PC-MRI with higher spatial in-plane resolution (1.6\u00d72.1 versus 2.3\u00d73.1 mm) with and without SF-3. Results were compared with a recently validated standard PC-MRI protocol and tested in vitro using a pulsatile flow phantom. Reduction of signal averages from 2 to 1 and application of SENSE accelerated flow measurements by a factor of 3.5 (5.2) using PC-MRI with SF-2 (SF-3) compared with standard PC-MRI. For blood flow rate through the pulmonary artery and aorta, as well as for the Q\n            <jats:sub>p<\/jats:sub>\n            \/Q\n            <jats:sub>s<\/jats:sub>\n            ratio we found negligible differences of \u00b13%, lower limits of agreement (mean\u00b12 SD) of \u22127% to \u221218%, and upper limits of agreement (mean\u00b12 SD) of +3 to +24%, demonstrating good agreement with standard PC-MRI. Mean Q\n            <jats:sub>p<\/jats:sub>\n            \/Q\n            <jats:sub>s<\/jats:sub>\n            ratio by standard PC-MRI was 1.69\u00b10.45 (range, 1.27 to 2.79). Interobserver variability was low, and high accuracy was confirmed in vitro for all protocols.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Conclusions\u2014<\/jats:italic>\n            <\/jats:bold>\n            PC-MRI for flow quantitation may be combined with SENSE to achieve a substantive reduction of scanning time. In children with left-to-right shunt, Q\n            <jats:sub>p<\/jats:sub>\n            \/Q\n            <jats:sub>s<\/jats:sub>\n            quantification is possible by PC-MRI+SF-3 in &lt;60 seconds. Use of higher in-plane resolution did not improve measurement results.\n          <\/jats:p>","DOI":"10.1161\/01.cir.0000087603.97036.c2","type":"journal-article","created":{"date-parts":[[2003,8,26]],"date-time":"2003-08-26T00:49:42Z","timestamp":1061858982000},"page":"1355-1361","update-policy":"http:\/\/dx.doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":85,"title":["Rapid Left-to-Right Shunt Quantification in Children by Phase-Contrast Magnetic Resonance Imaging Combined With Sensitivity Encoding (SENSE)"],"prefix":"10.1161","volume":"108","author":[{"given":"Philipp","family":"Beerbaum","sequence":"first","affiliation":[{"name":"From Klinik fu\u0308r Angeborene Herzfehler, Herz- und Diabeteszentrum, Nordrhein-Westfalen, Ruhr-Universita\u0308t Bochum, Germany, and Philips Medical Systems (J.G.), Best, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hermann","family":"Ko\u0308rperich","sequence":"additional","affiliation":[{"name":"From Klinik fu\u0308r Angeborene Herzfehler, Herz- und Diabeteszentrum, Nordrhein-Westfalen, Ruhr-Universita\u0308t Bochum, Germany, and Philips Medical Systems (J.G.), Best, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ju\u0308rgen","family":"Gieseke","sequence":"additional","affiliation":[{"name":"From Klinik fu\u0308r Angeborene Herzfehler, Herz- und Diabeteszentrum, Nordrhein-Westfalen, Ruhr-Universita\u0308t Bochum, Germany, and Philips Medical Systems (J.G.), Best, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Barth","sequence":"additional","affiliation":[{"name":"From Klinik fu\u0308r Angeborene Herzfehler, Herz- und Diabeteszentrum, Nordrhein-Westfalen, Ruhr-Universita\u0308t Bochum, Germany, and Philips Medical Systems (J.G.), Best, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Peuster","sequence":"additional","affiliation":[{"name":"From Klinik fu\u0308r Angeborene Herzfehler, Herz- und Diabeteszentrum, Nordrhein-Westfalen, Ruhr-Universita\u0308t Bochum, Germany, and Philips Medical Systems (J.G.), Best, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans","family":"Meyer","sequence":"additional","affiliation":[{"name":"From Klinik fu\u0308r Angeborene Herzfehler, Herz- und Diabeteszentrum, Nordrhein-Westfalen, Ruhr-Universita\u0308t Bochum, Germany, and Philips Medical Systems (J.G.), Best, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"e_1_3_3_1_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02011608"},{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002469910014"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.103.20.2476"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.81.1.67"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880030619"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910340326"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO;2-9"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910330208"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2586(199901)9:1<119::AID-JMRI16>3.0.CO;2-F"},{"key":"e_1_3_3_11_2","unstructured":"Wood  ML.  Fourier imaging. In:   Stark DD Bradley WG eds.   Magnetic Resonance Imaging.  St Louis:  Mosby Year Book;  1992:  21\u201367."},{"key":"e_1_3_3_12_2","first-page":"229","volume":"7","year":"1991","journal-title":"Magn Reson Q"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002469910009"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880030213"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10029"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910150308"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910390218"},{"key":"e_1_3_3_19_2","unstructured":"Kozerke  S.  Assessment of Heart Valve Function by Motion Adapted Magnetic Resonance Imaging [dissertation].  Zurich Switzerland:  Swiss Federal Institute of Technology Zurich;  2000."}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.CIR.0000087603.97036.C2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,6]],"date-time":"2024-05-06T18:40:15Z","timestamp":1715020815000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.CIR.0000087603.97036.C2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,9,16]]},"references-count":19,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2003,9,16]]}},"alternative-id":["10.1161\/01.CIR.0000087603.97036.C2"],"URL":"https:\/\/doi.org\/10.1161\/01.cir.0000087603.97036.c2","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,9,16]]},"assertion":[{"value":"2003-08-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}