{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T09:49:52Z","timestamp":1790934592152,"version":"4.1.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[2001,3,13]]},"abstract":"<jats:p>\n            <jats:italic>Background<\/jats:italic>\n            \u2014Complete bidirectional isthmus conduction block (CBIB) was initially assessed by sequential detailed activation mapping at both sides of the ablation line during proximal coronary sinus and anteroinferior right atrium pacing. Mapping only the ablation line (\u201con-site\u201d atrial potential analysis) was recently reported as a means of CBIB identification. The study was designed to compare these 2 techniques prospectively regarding the diagnosis of CBIB.\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Methods and Results<\/jats:italic>\n            \u2014In 76 consecutive patients (mean age, 63.4\u00b110.5 years), typical atrial flutter ablation was performed using either the activation mapping technique (group I) or on-site atrial potential analysis (group II). Criteria for CBIB using on-site atrial potential analysis was the recording of parallel, widely spaced double atrial potentials along the ablation line. The CBIB criterion was retrospectively searched using the alternative technique at the end of the procedure. In successful patients, the mean radiofrequency delivery duration was longer in group II (845\u00b1776 versus 534\u00b1363 s;\n            <jats:italic>P<\/jats:italic>\n            =0.03). On-site, clear-cut, widely spaced double atrial potentials and activation mapping suggesting CBIB were concomitantly observed in only 47 patients (54%), and ambiguous\/atypical double potentials were recorded in 31 patients (39%).\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Conclusions<\/jats:italic>\n            \u2014Although feasible, the on-site atrial potential analysis seemed to be inferior to the classic activation mapping technique, mainly because of the ambiguity of electrogram interpretation along the ablation line. However, when combined with the activation mapping technique, it provided additional information regarding isthmus conduction properties in some cases. Therefore, optimally, both methods should be used concomitantly.\n          <\/jats:p>","DOI":"10.1161\/01.cir.103.10.1434","type":"journal-article","created":{"date-parts":[[2012,6,12]],"date-time":"2012-06-12T00:09:32Z","timestamp":1339459772000},"page":"1434-1439","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":77,"title":["Catheter Ablation of Typical Atrial Flutter"],"prefix":"10.1161","volume":"103","author":[{"given":"Fre\u0301de\u0301ric","family":"Anselme","sequence":"first","affiliation":[{"name":"From Ho\u0302pital Charles Nicolle, Rouen, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnaud","family":"Savoure\u0301","sequence":"additional","affiliation":[{"name":"From Ho\u0302pital Charles Nicolle, Rouen, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alain","family":"Cribier","sequence":"additional","affiliation":[{"name":"From Ho\u0302pital Charles Nicolle, Rouen, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nadir","family":"Saoudi","sequence":"additional","affiliation":[{"name":"From Ho\u0302pital Charles Nicolle, Rouen, France."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_1_1_2","first-page":"116","volume":"63","year":"1970","unstructured":"Puech P, Latour H, Grolleau R. Le flutter et ses limites. Arch Mal Coeur. 1970;63:116\u2013144.","journal-title":"Arch Mal Coeur"},{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.94.3.398"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.92.7.1839"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.101.13.1568"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)91014-9"},{"key":"e_1_3_1_6_2","unstructured":"Saoudi N Poty H Anselme F et al. Evolution of concepts and techniques in radiofrequency catheter ablation for the common type of atrial flutter. In: Saoudi N Schoels W El Sheriff N eds. Atrial Flutter and Fibrillation: From Basic to Clinical Applications. Armonk NY: Futura Publishing Company Inc; 1998:269\u2013291."},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1999.tb00291.x"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.94.12.3204"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.96.8.2505"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1999.tb00243.x"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.99.4.534"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90793-Z"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.92.7.1839"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.99.21.2771"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(99)00211-9"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2000.tb00333.x"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.99.13.1700"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.95.6.1611"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.98.9.887"}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.CIR.103.10.1434","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T13:01:41Z","timestamp":1715518901000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.CIR.103.10.1434"}},"subtitle":["A Randomized Comparison of 2 Methods for Determining Complete Bidirectional Isthmus Block"],"short-title":[],"issued":{"date-parts":[[2001,3,13]]},"references-count":19,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2001,3,13]]}},"alternative-id":["10.1161\/01.CIR.103.10.1434"],"URL":"https:\/\/doi.org\/10.1161\/01.cir.103.10.1434","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,3,13]]},"assertion":[{"value":"2000-08-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2000-11-18","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2001-03-13","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}