{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:53:16Z","timestamp":1787017996455,"version":"build-2736575974"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[1995,1]]},"abstract":"<jats:p>\n                    <jats:italic>Background<\/jats:italic>\n                    Diagnosis of a mechanical mitral valve prosthesis thrombosis is currently made with transthoracic Doppler echocardiography and occasionally with fluoroscopy. However, identifying a thrombus on a valve prosthesis may be difficult, especially if the thrombus is nonobstructive. To prospectively define the role of transesophageal echocardiography for identification of nonobstructive thrombi, we studied a series of patients in whom the prosthetic valve was considered to function normally on clinical examination and transthoracic echocardiography.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Methods and Results<\/jats:italic>\n                    One hundred fourteen consecutive patients with mechanical mitral valve prosthesis were investigated by both transthoracic echocardiography and transesophageal echocardiography. These examinations were performed for recent systemic emboli (15 patients), fever of unknown etiology (11 patients), routine postoperative evaluation (56 patients), and other reasons (32 patients). Based on transthoracic echo diagnosis, all prostheses were considered normal. Yet, in 20 patients transesophageal echocardiography revealed the presence of a 2- to 15-mm-long mobile thrombus localized on the atrial surface of the prosthesis. When compared with the remaining 94 patients with no visible thrombi, there was no significant difference between the two groups in terms of incidence of atrial fibrillation (65% versus 52%), left atrial size (48\u00b19 versus 51\u00b113 mm), left ventricular end-diastolic diameter (49\u00b110 versus 51\u00b113 mm) and fractional shortening (28\u00b19% versus 31\u00b110%), presence of spontaneous contrast in the left atrium (40% versus 41%), transprosthetic mean pressure gradient (4.0\u00b11.4 versus 3.9\u00b11.5 mm Hg), or the type of prosthesis used. After we discovered a nonobstructive thrombosis, patients were treated with heparin (n=9) or oral anticoagulation (n=11). The presence of a localized thrombus was confirmed in 3 patients who were operated on. In the present study, evolution appeared to depend on thrombus size: of 14 patients exhibiting a small (&lt;5 mm) thrombus, 10 had an uneventful course, whereas 5 of 6 patients with a large (\u22655 mm) thrombus developed complications or died.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Conclusions<\/jats:italic>\n                    Transesophageal echocardiography appears to be a reliable method to diagnose thrombi on a mechanical mitral valve prosthesis, even when transthoracic Doppler echocardiographic parameters appear to be normal. Transesophageal echo assessment of thrombus size may be helpful in deciding whether a patient with mitral prosthesis should be treated by anticoagulation, thrombolysis, or valve rereplacement. .\n                  <\/jats:p>","DOI":"10.1161\/01.cir.91.1.103","type":"journal-article","created":{"date-parts":[[2012,6,11]],"date-time":"2012-06-11T20:34:42Z","timestamp":1339446882000},"page":"103-110","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":73,"title":["Transesophageal Echocardiography for the Diagnosis and Management of Nonobstructive Thrombosis of Mechanical Mitral Valve Prosthesis"],"prefix":"10.1161","volume":"91","author":[{"given":"Pascal","family":"Gueret","sequence":"first","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Vignon","sequence":"additional","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Fournier","sequence":"additional","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Marc","family":"Chabernaud","sequence":"additional","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie","family":"Gomez","sequence":"additional","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"LaCroix","sequence":"additional","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julien","family":"Bensaid","sequence":"additional","affiliation":[{"name":"From the Department of Cardiology, University Hospital Dupuytren, Limoges, France."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(89)90177-X"},{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(10)80178-0"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0167-5273(88)90061-7"},{"key":"e_1_3_2_4_2","unstructured":"Roudaut R Labbe T Lorient-Roudaut MF Gosse P Baudet E Fontan F Besse P Dallochio M. Mechanical cardiac valve thrombosis: is fibrinolysis justified? Circulation. 1992;86(suppl II):II-8-II-15."},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(82)90237-X"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.87.1.8419020"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.83.6.2040048"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(91)90527-G"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90443-Q"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(92)90292-4"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90010-6"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(90)90372-8"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(14)80433-1"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(91)91006-9"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0025-6196(12)65529-3"},{"key":"e_1_3_2_16_2","unstructured":"Taylor D Chan KL: Transesophageal echocardiographic identification of two types of left atrial spontaneous contrast in patients with mechanical prosthetic valve. Circulation. 1991;83(suppl II):II-116. Abstract."},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(92)90276-2"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.1992.tb00505.x"},{"key":"e_1_3_2_19_2","first-page":"404","volume":"12","year":"1991","unstructured":"Gueret P, Fournier P, Chabernaud JM, Lacroix P, Bensaid J. Normal transthoracic echo-Doppler parameters cannot rule out thrombosis of mitral mechanical prosthesis: demonstration by transesophageal echocardiography. Eur Heart J. 1991;12:404. Abstract.","journal-title":"Eur Heart J"},{"key":"e_1_3_2_20_2","first-page":"332","volume":"15","year":"1990","unstructured":"Burchfiel CM, Hammermeister KE, Krause-Steinrauf H, Sethi GK, Henderson WG, Crawford MH, Wong M. Left atrial dimension and risk of systemic embolism in patients with a prosthetic heart valve. J Am Coll Cardiol. 1990;15:332-341.","journal-title":"J Am Coll Cardiol"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(88)90283-5"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(91)90104-S"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(86)90107-7"},{"key":"e_1_3_2_24_2","first-page":"239","volume":"13","year":"1992","unstructured":"Malergue MC, Maribas P, Vignon P, Temkine J, Bical O, Gueret P. High incidence of asymptomatic thrombosis of mitral mechanical prosthesis in the early post-operative period: demonstration by systematic transesophageal echocardiography. Eur Heart J. 1992;13:239. Abstract.","journal-title":"Eur Heart J"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.87.1.8419018"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(87)80053-0"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0025-6196(12)62744-X"},{"key":"e_1_3_2_28_2","first-page":"397","volume":"11","year":"1990","unstructured":"DeCoot P, Kacenelenbogen R, Gassavelis C, Peperstraete B, Verbeet T, Bat JP, Deuvaert F, Telerman M. Biplane transesophageal echocardiography: when is it useful? Eur Heart J. 1990;11:397. Abstract.","journal-title":"Eur Heart J"},{"key":"e_1_3_2_29_2","first-page":"285","volume":"13","year":"1992","unstructured":"Flachskampf FA, Hoffman R, Hanrath P. Value of multiplane transesophageal echocardiography for the assessment of prosthetic valve regurgitation. Eur Heart J. 1992;13:285. Abstract.","journal-title":"Eur Heart J"}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.CIR.91.1.103","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T11:43:53Z","timestamp":1715514233000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.CIR.91.1.103"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1995,1]]}},"alternative-id":["10.1161\/01.CIR.91.1.103"],"URL":"https:\/\/doi.org\/10.1161\/01.cir.91.1.103","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,1]]},"assertion":[{"value":"1994-05-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"1994-07-31","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"1995-01-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}