{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T08:42:32Z","timestamp":1791016952333,"version":"4.1.0"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[1995,6,15]]},"abstract":"<jats:p>\n                    <jats:italic>Background<\/jats:italic>\n                    Velocity-encoded, phase-difference magnetic resonance imaging (MRI) has been shown to provide an accurate assessment of shunt magnitude in patients with large atrial septal defects, but its ability to determine shunt magnitude in patients with intracardiac left-to-right shunts of various locations and sizes has not been evaluated in a prospective and blinded manner. The objective of the present study was to determine whether velocity-encoded, phase-difference MRI can assess the magnitude of intracardiac left-to-right shunting in humans.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Methods and Results<\/jats:italic>\n                    Twenty-one subjects (15 women and 6 men; age range, 15 to 72 years) underwent velocity-encoded, phase-difference MRI measurements of flow in the proximal aorta and pulmonary artery, followed immediately by cardiac catheterization. The presence of left-to-right intracardiac shunting was assessed with hydrogen inhalation, after which shunt magnitude was measured by the oximetric and indocyanine green techniques. Of the 21 patients, 12 had left-to-right intracardiac shunting detected by hydrogen inhalation. There was a good correlation (\n                    <jats:italic>r<\/jats:italic>\n                    =.94) between the invasive and MRI assessments of shunt magnitude. In comparison to oximetry and indocyanine green, MRI correctly identified the 12 patients with a ratio of pulmonary to systemic flow (Qp\/Qs) of &lt;1.5 (9 without intracardiac shunting and 3 with small shunts) and the 9 patients with a Qp\/Qs of \u22651.5 (6 with atrial septal defect, 1 with ventricular septal defect, 1 with patent ductus arteriosus, and 1 with both atrial septal defect and patent ductus arteriosus).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:italic>Conclusions<\/jats:italic>\n                    Compared with measurements obtained during cardiac catheterization, velocity-encoded, phase-difference MRI measurements of flow in the proximal great vessels can reliably assess the magnitude of intracardiac left-to-right shunting.\n                  <\/jats:p>","DOI":"10.1161\/01.cir.91.12.2955","type":"journal-article","created":{"date-parts":[[2012,6,11]],"date-time":"2012-06-11T20:34:42Z","timestamp":1339446882000},"page":"2955-2960","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":152,"title":["Assessment of Left-to-Right Intracardiac Shunting by Velocity-Encoded, Phase-Difference Magnetic Resonance Imaging"],"prefix":"10.1161","volume":"91","author":[{"given":"W. Gregory","family":"Hundley","sequence":"first","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong F.","family":"Li","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard A.","family":"Lange","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis P.","family":"Pfeifer","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin M.","family":"Meshack","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John E.","family":"Willard","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Landau","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Duwayne","family":"Willett","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. David","family":"Hillis","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald M.","family":"Peshock","sequence":"additional","affiliation":[{"name":"From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., B.M.M., J.E.W., C.L., D.W., L.D.H., R.M.P.) and Radiology (H.F.L., D.P.P., R.M.P.), University of Texas Southwestern Medical Center at Dallas."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","unstructured":"Grossman W. Shunt detection and measurement. In: Grossman W Baim DS eds. Cardiac Catheterization Angiography and Intervention. 4th ed. Philadelphia Pa: Lea & Febiger; 1991:166-181."},{"key":"e_1_3_2_2_2","unstructured":"Daniel WC Lange RA Willard JE Landau C Hillis LD. Oximetric versus indicator dilution techniques for quantitating intracardiac left-to-right shunting in adults. Am J Cardiol. In press."},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(80)90068-5"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90471-2"},{"key":"e_1_3_2_5_2","first-page":"77","volume":"55","year":"1960","unstructured":"Carter SA, Bajec DF, Yannicelli E, Wood EH. Estimation of left-to-right shunt from arterial dilution curves. J Lab Clin Med. 1960;55:77-88.","journal-title":"J Lab Clin Med"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810110505"},{"key":"e_1_3_2_7_2","first-page":"162","volume":"24","year":"1962","unstructured":"Folse R, Braunwald E. Pulmonary vascular dilution curves recorded by external detection in the diagnosis of left-to-right shunts. Br Heart J. 1962;24:162-172.","journal-title":"Br Heart J"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0033-0620(77)90003-2"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(88)90099-X"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.69.1.6689649"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(92)90612-Y"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.47.5.1049"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1988.03720020055037"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.171.3.2717753"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a059857"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-199302000-00004"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(92)90245-V"},{"key":"e_1_3_2_18_2","first-page":"453","volume":"159","year":"1992","unstructured":"Mostbeck GH, Caputo GR, Higgins CB. MR measurement of blood flow in the cardiovascular system. Am J Radiol. 1992;159:453-461.","journal-title":"Am J Radiol"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90384-Y"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810200206"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)90890-O"},{"key":"e_1_3_2_22_2","unstructured":"NessAvier M. Breathhold cines using phase encoding grouping. In: Pohost GM ed. Cardiovascular Applications of Magnetic Resonance. Mount Kisco NY: Futura Publishing; 1993:133-145."},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.28.4.542"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1172\/JCI101840"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(89)90086-0"},{"key":"e_1_3_2_27_2","first-page":"689","volume":"149","year":"1987","unstructured":"Sechtem U, Pflugfelder P, Cassidy MC, Holt W, Wolfe C, Higgins CB. Ventricular septal defect: visualization of shunt flow and determination of shunt size by cine MR imaging. Am J Radiol. 1987;149:689-692.","journal-title":"Am J Radiol"},{"key":"e_1_3_2_28_2","unstructured":"Mohiaddin RH Kilbner PJ Amanuma M Pennell DJ Longmore DB. MR flow imaging of healthy and diseased mitral valves. Radiology. 1990;177(P):100. Abstract."},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290611"}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.CIR.91.12.2955","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T11:39:33Z","timestamp":1715513973000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.CIR.91.12.2955"}},"subtitle":["A Comparison With Oximetric and Indicator Dilution Techniques"],"short-title":[],"issued":{"date-parts":[[1995,6,15]]},"references-count":29,"journal-issue":{"issue":"12","published-print":{"date-parts":[[1995,6,15]]}},"alternative-id":["10.1161\/01.CIR.91.12.2955"],"URL":"https:\/\/doi.org\/10.1161\/01.cir.91.12.2955","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,6,15]]},"assertion":[{"value":"1994-10-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"1994-12-21","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"1995-06-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}