{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T05:55:23Z","timestamp":1725861323744},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Stroke"],"published-print":{"date-parts":[[2002,7]]},"abstract":"<jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Background and Purpose<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            The development of intracranial collateral circulation is associated with a lower risk of stroke. A noninvasive technique that can reliably detect the presence of intracranial collaterals would be a valuable factor in the assessment of risk in patients with occlusive cerebrovascular disease.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Methods<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            Color velocity imaging quantification was used to measure the blood flow volume of the common carotid and vertebral arteries in 40 patients with carotid occlusive disease. The blood flow volumes in these arteries were correlated with angiographic evidence of collaterals to establish the best cutoffs for detecting intracranial collateral circulation.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Results<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            A blood flow volume of either \u2265370 mL\/min in the common carotid artery or \u2265120 mL\/min in the vertebral artery was indicative of the presence of intracranial collaterals. The sensitivity and specificity for the common carotid artery were 92.3% [95% confidence interval (CI), 62.1 to 99.6] and 92.1% (95% CI, 77.5 to 97.9), respectively. The sensitivity and specificity for the vertebral artery were 75.0% (95% CI, 35.6 to 95.5) and 87.5% (95% CI, 66.5 to 96.7), respectively.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>\n                <jats:bold>\n                  <jats:italic>Conclusions<\/jats:italic>\n                <\/jats:bold>\n                \u2014\n              <\/jats:italic>\n            <\/jats:bold>\n            Color velocity imaging quantification offers a noninvasive, accurate method for detecting the presence of intracranial collateral circulation and quantifying its magnitude. This technique would be a useful adjunct in screening or continuous monitoring of patients with severe carotid occlusive disease.\n          <\/jats:p>","DOI":"10.1161\/01.str.0000019291.99038.4c","type":"journal-article","created":{"date-parts":[[2002,7,28]],"date-time":"2002-07-28T23:16:47Z","timestamp":1027898207000},"page":"1795-1798","update-policy":"http:\/\/dx.doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":9,"title":["Color Velocity Imaging Quantification in the Detection of Intracranial Collateral Flow"],"prefix":"10.1161","volume":"33","author":[{"given":"S.S.Y.","family":"Ho","sequence":"first","affiliation":[{"name":"From the Department of Radiology and Organ Imaging, Prince of Wales Hospital, Hong Kong."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Metreweli","sequence":"additional","affiliation":[{"name":"From the Department of Radiology and Organ Imaging, Prince of Wales Hospital, Hong Kong."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.H.","family":"Yu","sequence":"additional","affiliation":[{"name":"From the Department of Radiology and Organ Imaging, Prince of Wales Hospital, Hong Kong."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"e_1_3_1_1_2","unstructured":"Fisher M. Clinical Atlas of Cerebrovascular Disorders. London UK: Mosby Year Book; 1994: 3: 2\u20133.23."},{"key":"e_1_3_1_2_2","unstructured":"Sokoloff L. Anatomy of cerebral circulation.In: Welch KMA Caplan LR Reis DJ SieSjo BK Weir B eds. Primer on Cerebrovascular Disease. San Diego Calif: Academic Press; 1997: 3\u20135."},{"key":"e_1_3_1_3_2","first-page":"19","volume":"14","year":"1993","unstructured":"Ross MR, Pelc NJ, Enzmann DR. Qualitative phase contrast MRA in the normal and abnormal circle of Willis. AJNR Am J Neuroradiol. 1993; 14: 19\u201325.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1159\/000117130"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.31.1.128"},{"key":"e_1_3_1_6_2","unstructured":"Von Reutern GM von Budingen HJ eds. Ultrasound Diagnosis of Cerebrovascular Disease. New York NY: Thieme Medical Publishers; 1992: 37\u201352."},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0301-5629(85)90035-3"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1080\/028418500127345299"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1001\/archneurpsyc.1957.02330390017003"},{"key":"e_1_3_1_10_2","first-page":"195","volume":"16","year":"1995","unstructured":"Muller M, Hermes M, Bruckmann H, Schimrigk K. Transcranial Doppler ultrasound in the evaluation of collateral blood flow in patients with internal carotid artery occlusion: correlation with cerebral angiography. AJNR Am J Neuroradiol. 1995; 16: 195\u2013202.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_1_11_2","first-page":"127","volume":"18","year":"1997","unstructured":"Baumgartner RW, Naumgartner I, Mattle HP, Schroth G. Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis. AJNR Am J Neuroradiol. 1997; 18: 127\u2013133.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199303000-00004"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00588129"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.24.8.8342196"},{"key":"e_1_3_1_15_2","first-page":"1275","volume":"8","year":"1997","unstructured":"Marinoni M, Ginanneschi A, Forleo P, Amaducci L. Technical limits in transcranial Doppler recording: inadequate acoustic windows. Ultrasound Med Biol. 1997; 8: 1275\u20131277.","journal-title":"Ultrasound Med Biol"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.30.7.1450"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon199333190"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1076-6332(97)80208-5"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-5629(97)00047-1"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.26.2.214"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.30.12.2671"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003300000618"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon1996611"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.31.6.1342"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.178.3.1780551"}],"container-title":["Stroke"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.STR.0000019291.99038.4C","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T20:30:38Z","timestamp":1715545838000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.STR.0000019291.99038.4C"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,7]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2002,7]]}},"alternative-id":["10.1161\/01.STR.0000019291.99038.4C"],"URL":"https:\/\/doi.org\/10.1161\/01.str.0000019291.99038.4c","relation":{},"ISSN":["0039-2499","1524-4628"],"issn-type":[{"value":"0039-2499","type":"print"},{"value":"1524-4628","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,7]]},"assertion":[{"value":"2001-05-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2002-03-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2002-07-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}