{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T16:44:42Z","timestamp":1790700282921,"version":"4.1.0"},"reference-count":6,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Stroke"],"published-print":{"date-parts":[[2005,12]]},"abstract":"<jats:p>\n            <jats:bold>\n              <jats:italic>Background and Purpose\u2014<\/jats:italic>\n            <\/jats:bold>\n            Previous studies on the hyperdense middle cerebral artery (MCA) sign were conducted using \u22655-mm thickness noncontrast-computed tomography (NCT). The purpose of this study was to compare thin-section NCT with 5-mm NCT in the detection of thrombus in acute ischemic stroke.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Methods\u2014<\/jats:italic>\n            <\/jats:bold>\n            Enrolled were consecutive 51 patients with acute infarction in the anterior or MCA territory. All patients underwent both 5-mm NCT and either 1.25- or 1-mm thin-section helical NCT within 6 hours of symptom onset. Patients were assigned to either the single or multisegmental occlusion group, depending on the thrombus extent on thin-section NCT. Thin-section NCT and 5-mm NCT were compared in the detection of thrombi.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Results\u2014<\/jats:italic>\n            <\/jats:bold>\n            Thrombi were identified in 45 patients (88%) on thin-section NCT and 16 on 5-mm NCT (31%;\n            <jats:italic>P<\/jats:italic>\n            &lt;0.001). No occlusion was seen in 6 patients. Both sensitivity and specificity of thin-section NCT in detection of thrombus were 100%.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Conclusions\u2014<\/jats:italic>\n            <\/jats:bold>\n            Acute thrombus can be detected with higher sensitivity on thin-section NCT than on 5-mm NCT, and its extent is more accurately determined on thin-section NCT.\n          <\/jats:p>","DOI":"10.1161\/01.str.0000185720.03803.41","type":"journal-article","created":{"date-parts":[[2005,11,4]],"date-time":"2005-11-04T01:49:50Z","timestamp":1131068990000},"page":"2745-2747","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":66,"title":["Detection of Thrombus in Acute Ischemic Stroke"],"prefix":"10.1161","volume":"36","author":[{"given":"Eung Yeop","family":"Kim","sequence":"first","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seung-Koo","family":"Lee","sequence":"additional","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Joon","family":"Kim","sequence":"additional","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang-Hyun","family":"Suh","sequence":"additional","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinna","family":"Kim","sequence":"additional","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Hoe","family":"Heo","sequence":"additional","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Ik","family":"Kim","sequence":"additional","affiliation":[{"name":"From the Department of Radiology, Research Institute of Radiologic Science (E.Y.K., S.-K.L., D.J.K., S.-H.S., J.K., D.I.K.) and the Department of Neurology (J.H.H.), Yonsei University College of Medicine, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.14.5.6658961"},{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.23.3.1542889"},{"key":"e_1_3_2_3_2","first-page":"9","volume":"15","year":"1994","unstructured":"von Kummer R, Meyding-Lamade U, Forsting M, Rosin L, Rieke K, Hacke W, Sartor K. Sensitivity and prognostic value of early CT in occlusion of the middle cerebral artery trunk. AJNR Am J Neuroradiol. 1994; 15: 9\u201315;discussion 16\u201318.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_2_4_2","first-page":"257","volume":"13","year":"1992","unstructured":"Tomsick T, Brott T, Barsan W, Broderick J, Haley EC, Spilker J. Thrombus localization with emergency cerebral CT. AJNR Am J Neuroradiol. 1992; 13: 257\u2013263.","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.30.4.769"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.32.1.84"}],"container-title":["Stroke"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.STR.0000185720.03803.41","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T21:25:01Z","timestamp":1715549101000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.STR.0000185720.03803.41"}},"subtitle":["Value of Thin-Section Noncontrast-Computed Tomography"],"short-title":[],"issued":{"date-parts":[[2005,12]]},"references-count":6,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2005,12]]}},"alternative-id":["10.1161\/01.STR.0000185720.03803.41"],"URL":"https:\/\/doi.org\/10.1161\/01.str.0000185720.03803.41","relation":{},"ISSN":["0039-2499","1524-4628"],"issn-type":[{"value":"0039-2499","type":"print"},{"value":"1524-4628","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,12]]},"assertion":[{"value":"2005-07-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2005-08-05","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2005-11-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}