{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T11:37:18Z","timestamp":1771069038378,"version":"3.50.1"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Stroke"],"published-print":{"date-parts":[[1997,4]]},"abstract":"<jats:p>\n            <jats:italic>Background and Purpose<\/jats:italic>\n            The value of carotid endarterectomy (CEA) depends on the safety of the operation. Transcranial Doppler ultrasound (TCD) was used to evaluate the possibilities of hypoperfusion, hyperperfusion, and embolization as causes of stroke and to evaluate the significance of Doppler microembolic signals (DMES).\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Methods<\/jats:italic>\n            Five hundred CEAs were monitored with TCD of the ipsilateral middle cerebral artery during various phases of CEA to determine hemodynamic changes and incidence of DMES. Complications were graded according to their severity, and their probable cause was determined from TCD criteria and review of hospital charts.\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Results<\/jats:italic>\n            We observed 24 cerebrovascular complications (4.8%), including 9 with transient ischemic attacks and 15 (3%) with permanent deficits. Among all cerebrovascular complications, embolism was judged to be responsible in 13 (54%;\n            <jats:italic>P<\/jats:italic>\n            &lt;.02 compared with hypoperfusion), hyperperfusion in 7 (29%;\n            <jats:italic>P<\/jats:italic>\n            &lt;.14 compared with hypoperfusion), and hypoperfusion in 4 (17%;\n            <jats:italic>P<\/jats:italic>\n            &lt;.08 compared with embolism plus hyperperfusion). The surgeons responded to TCD information by several strategies depending on the TCD information. The incidence of permanent deficits diminished from 7% in the first 100 operations to 2% in the last 400 (\n            <jats:italic>P<\/jats:italic>\n            \u2264.01). Shunting was more strongly associated with cerebrovascular complications than nonshunting, but this difference was not significant (\n            <jats:italic>P<\/jats:italic>\n            =.24). Intraoperative prevalence of DMES was strongly associated with cerebrovascular complications (\n            <jats:italic>P<\/jats:italic>\n            =.02).\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Conclusions<\/jats:italic>\n            Embolism is the principal cause of cerebrovascular complications from CEA; hyperperfusion and hypoperfusion are also important causes. TCD provides information that allows prompt identification and treatment of these three major causes of stroke from this operation. The perioperative stroke rate can be reduced by appropriate measures, taken by the surgeons, based on findings of TCD monitoring.\n          <\/jats:p>","DOI":"10.1161\/01.str.28.4.685","type":"journal-article","created":{"date-parts":[[2011,6,17]],"date-time":"2011-06-17T20:08:03Z","timestamp":1308341283000},"page":"685-691","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":181,"title":["Transcranial Doppler Monitoring and Causes of Stroke From Carotid Endarterectomy"],"prefix":"10.1161","volume":"28","author":[{"given":"Merrill P.","family":"Spencer","sequence":"first","affiliation":[{"name":"From Sound Vascular Monitoring and the Institute of Applied Physiology and Medicine, Seattle, Wash."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1974.41.3.0310"},{"key":"e_1_3_2_2_2","first-page":"31","volume":"62","year":"1967","unstructured":"Larson CP, Ehrenfeld WK, Wade JG, Wylie EJ. Jugular venous oxygen saturation as an index of adequacy of cerebral oxygenation. Surgery. 1967;62:31-39.","journal-title":"Surgery"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0950-821X(89)80050-7"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1969.01340180026005"},{"key":"e_1_3_2_5_2","first-page":"310","volume":"13","year":"1991","unstructured":"Archie JP. Technique and clinical results of carotid stump back-pressure to determine selective shunting during carotid endarterectomy. J Vasc Surg. 1991;13:310-326.","journal-title":"J Vasc Surg"},{"key":"e_1_3_2_6_2","first-page":"824","volume":"22","year":"1987","unstructured":"Schroeder T, Sillesen H, Sorensen O, Engell HC. Cerebral hyperperfusion following carotid endarterectomy. J Neurosurg. 1987;22:824-829.","journal-title":"J Neurosurg"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.17.6.3810729"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1996.01430170072014"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(96)70260-4"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(94)70096-6"},{"key":"e_1_3_2_11_2","first-page":"423","volume":"56","year":"1985","unstructured":"Ringelstein EB, Richert F, Bardos S, Minale C, Alsukun M, Zeplin H, Sch\u00f6ndube F, Zeumer H, Messmer B. Transkraniell-sonographisches monitoring des blutflusses der A. cerebri media w\u00e4hrend reanalisierender operationen an der extrakraniellen A. carotis interna. Nervenarzt. 1985;56:423-430.","journal-title":"Nervenarzt"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800730204"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800740412"},{"key":"e_1_3_2_14_2","unstructured":"Spencer MP Aaslid R Castillos F McDaniel M. Intraoperative monitor for intracranial hemodynamics. In: Proceedings and abstracts of the 32nd Annual Convention of the American Institute of Ultrasound in Medicine; October 6-9 1987; New Orleans La."},{"key":"e_1_3_2_15_2","first-page":"1314","volume":"76","year":"1989","unstructured":"Laman DM, Voorwinde A, Davies G, Van Duijin H. Intraoperative internal carotid artery restenosis detected by transcranial Doppler monitoring. Br J Surg. 1989;76:1314-1316.","journal-title":"Br J Surg"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1227\/00006123-198909000-00011"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01405270"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1227\/00006123-199001000-00008"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6109(16)45047-4"},{"key":"e_1_3_2_20_2","first-page":"80","volume":"9","year":"1990","unstructured":"Fisher DM, Fisher PA, Pietrzak NA. Efficacy of transcranial Doppler for monitoring middle cerebral arterial velocity during carotid endarterectomy. J Cardiovasc Tech. 1990;9:80-81.","journal-title":"J Cardiovasc Tech"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.2301\/neurosonology.6.20"},{"key":"e_1_3_2_22_2","first-page":"79","volume":"9","year":"1990","unstructured":"J\u00f8rgensen L, Schroeder T, Knudsen L, Perko M. Transcranial Doppler monitoring and carotid artery blood pressure measurements during carotid endarterectomy. J Cardiovasc Tech. 1990;9:79-80.","journal-title":"J Cardiovasc Tech"},{"key":"e_1_3_2_23_2","doi-asserted-by":"crossref","unstructured":"Spencer MP Thomas GI Moehring MA. Relation between middle cerebral artery blood flow velocity and stump pressure during carotid endarterectomy. Stroke. 1992;23: 1439-1445.","DOI":"10.1161\/01.STR.23.10.1439"},{"key":"e_1_3_2_24_2","first-page":"174","volume":"8","year":"1989","unstructured":"Sollmann WP, Lorenz M, Gaab MR, Dorfm\u00fcller G, Hinrichs H, Feistner H. Intraoperative monitoring with TCD, EEG and evoked potentials in extracranial cerebrovascular surgery. J Cardiovasc Tech. 1989;8:174-176.","journal-title":"J Cardiovasc Tech"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1020301"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0950-821X(05)80814-X"},{"key":"e_1_3_2_27_2","first-page":"315","volume":"9","year":"1990","unstructured":"Steiger HJ, Schoch C, Zhong Y. The value of carotid surgery monitoring with TCD and EEG. J Cardiovasc Tech. 1990;9:315-316.","journal-title":"J Cardiovasc Tech"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.21.3.2408197"},{"key":"e_1_3_2_29_2","unstructured":"Spencer MP. Detection of cerebral arterial emboli with transcranial Doppler. In: Newell DW Aaslid R eds. Transcranial Doppler. New York NY: Raven Press Ltd; 1992:215-230."},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.26.6.1123"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.23.11.1440706"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/0741-5214(94)90181-3"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.25.5.7909393"},{"key":"e_1_3_2_34_2","first-page":"A1357","volume":"6","year":"1992","unstructured":"Spencer MP, Klepper JR. Ultrasonic frequency dependence of Doppler detectability of arterial microemboli. FASEB J. 1992;6:A1357.","journal-title":"FASEB J"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1109\/10.277269"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0950-821X(05)80231-2"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.24.5.8304996"}],"container-title":["Stroke"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.STR.28.4.685","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T22:16:50Z","timestamp":1715552210000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.STR.28.4.685"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,4]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1997,4]]}},"alternative-id":["10.1161\/01.STR.28.4.685"],"URL":"https:\/\/doi.org\/10.1161\/01.str.28.4.685","relation":{},"ISSN":["0039-2499","1524-4628"],"issn-type":[{"value":"0039-2499","type":"print"},{"value":"1524-4628","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,4]]},"assertion":[{"value":"1996-12-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"1997-01-31","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"1997-04-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}