{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T17:15:19Z","timestamp":1784049319032,"version":"3.55.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Stroke"],"published-print":{"date-parts":[[2000,6]]},"abstract":"<jats:p>\n            <jats:italic>Background and Purpose<\/jats:italic>\n            \u2014A noninvasive reliable technique that can reveal cerebral blood flow volume could be a valuable tool in screening programs for stroke prevention. In diagnostic ultrasonography, spectral Doppler imaging (SDI) is popular among sonologists and vascular technologists to estimate blood flow volume despite its documented inaccuracy and the availability of the more accurate technique of color velocity imaging (CVI). The aim of the present study was to demonstrate the discrepancy of blood flow volume estimation with CVI and SDI with use of an \u201cinternal\u201d standard.\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Methods<\/jats:italic>\n            \u2014The common, internal, and external carotid arteries of 50 healthy subjects (22 men, 28 women, age range 19 to 54 years) were examined with CVI and SDI. The total blood flow volume of the internal and external carotid arteries was then compared with the ipsilateral common carotid artery flow. An accurate technique would demonstrate no difference. The difference (expressed as a percent inconsistency) was therefore a measure of the accuracy of the method.\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Results<\/jats:italic>\n            \u2014The mean\u00b1SD inconsistency was found to be 10.6\u00b18.3% for CVI and 27.9\u00b114.3% for SDI. The difference in inconsistency between CVI and SDI in measurement of carotid blood flow volume was statistically significant (\n            <jats:italic>P<\/jats:italic>\n            &lt;0.01).\n          <\/jats:p>\n          <jats:p>\n            <jats:italic>Conclusions<\/jats:italic>\n            \u2014CVI is more accurate than SDI in the determination of blood flow volume in the carotid arteries. For noninvasive clinical estimation of cerebrovascular blood flow volume, CVI quantification should be the preferred technique.\n          <\/jats:p>","DOI":"10.1161\/01.str.31.6.1342","type":"journal-article","created":{"date-parts":[[2011,6,17]],"date-time":"2011-06-17T20:08:03Z","timestamp":1308341283000},"page":"1342-1345","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":21,"title":["Preferred Technique for Blood Flow Volume Measurement in Cerebrovascular Disease"],"prefix":"10.1161","volume":"31","author":[{"given":"Stella S. Y.","family":"Ho","sequence":"first","affiliation":[{"name":"From the Department of Diagnostic Radiology and Organ Imaging, Prince of Wales of Hospital, Hong Kong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Constantine","family":"Metreweli","sequence":"additional","affiliation":[{"name":"From the Department of Diagnostic Radiology and Organ Imaging, Prince of Wales of Hospital, Hong Kong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","first-page":"319","volume":"33","year":"1991","unstructured":"Wada T, Kodaira K, Fujishiro K, Okamura T. Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings. Stroke. 1991;33:319\u2013323.","journal-title":"Stroke"},{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon1996611"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.30.1.76"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/str.14.2.6220490"},{"key":"e_1_3_2_5_2","first-page":"371","volume":"6","year":"1987","unstructured":"Dalla CF, Signorini GP, Previato Schiesari A. Quantitative evaluation of carotid blood flow before and after surgery. Int Angiol. 1987;6:371\u2013373.","journal-title":"Int Angiol"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/jon19933289"},{"key":"e_1_3_2_7_2","first-page":"145","volume":"5","year":"1996","unstructured":"Eicke BM, Tegeler CH. Ultrasonic quantification flow volumetry of the carotid arteries: initial experience with a color flow M-mode system. Cerebrovasc Dis. 1996;5:145\u2013149.","journal-title":"Cerebrovasc Dis"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.7863\/jum.1995.14.12.939"},{"key":"e_1_3_2_9_2","unstructured":"Eicke BM Tegeler CH. Ultrasonic quantification of blood flow volume. In Tegeler CH Babikian VL Gomez CR eds. Neurosonology. New York NY: Mosby\u2013Year Book; 1996:101\u2013110."},{"key":"e_1_3_2_10_2","first-page":"175","volume":"19","year":"1995","unstructured":"Winkler AJ, Wu J, Case T, Ricci MA. An experimental study of the accuracy of volume flow measurements using commercial ultrasound systems. J Vasc Tech. 1995;19:175\u2013180.","journal-title":"J Vasc Tech"},{"key":"e_1_3_2_11_2","first-page":"99","volume":"9","year":"1975","unstructured":"Olson RM, Cooke JP. Human carotid artery diameter and flow by a noninvasive technique. Med Instrum. 1975;9:99\u2013102.","journal-title":"Med Instrum"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0301-5629(85)90035-3"},{"key":"e_1_3_2_13_2","unstructured":"Kremkau FW. Doppler Ultrasound: Principles and Instruments 2nd ed. Philadelphia Pa: WB Saunders; 1995:89\u2013119."},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0301-5629(85)90003-1"},{"key":"e_1_3_2_15_2","unstructured":"Landwehr P. Basic hemodynamics. In: Wolf KJ Fobbe F eds. Color Duplex Sonography: Principles and Clinical Applications. New York NY: Thieme Medical Publishers Inc: 1995:20\u201336."},{"key":"e_1_3_2_16_2","unstructured":"Fisher M. The pathophysiology of ischaemic stroke. In: Fisher M ed. Clinical Atlas of Cerebrovascular Disorders. London UK: Mosby\u2013Year Book; 1994:3(2)-3(23)."},{"key":"e_1_3_2_17_2","unstructured":"Pick TP Howden R. Gray\u2019s Anatomy 19th ed. Philadelphia Pa: Running Press; 1974:703\u2013705."},{"key":"e_1_3_2_18_2","doi-asserted-by":"crossref","unstructured":"Orrison WW Lewine JD Sanders JA Hartshorne MF eds. Functional Brain Imaging. St Louis Mo: Mosby\u2013Year Book; 1995.","DOI":"10.1016\/B978-0-8151-6509-5.50005-9"}],"container-title":["Stroke"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.STR.31.6.1342","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T22:04:50Z","timestamp":1715551490000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/01.STR.31.6.1342"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,6]]},"references-count":18,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2000,6]]}},"alternative-id":["10.1161\/01.STR.31.6.1342"],"URL":"https:\/\/doi.org\/10.1161\/01.str.31.6.1342","relation":{},"ISSN":["0039-2499","1524-4628"],"issn-type":[{"value":"0039-2499","type":"print"},{"value":"1524-4628","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,6]]},"assertion":[{"value":"2000-01-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2000-03-15","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2000-06-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}