{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T19:10:07Z","timestamp":1792869007644,"version":"4.5.0"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circ: Arrhythmia and Electrophysiology"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND:<\/jats:title>\n            <jats:p>Left bundle branch area pacing (LBBAP) may be an alternative to biventricular pacing (BVP) for cardiac resynchronization therapy (CRT). We sought to compare the acute hemodynamic and ECG effects of LBBAP, BVP, and left bundle-optimized therapy CRT (LOT-CRT) in CRT candidates with advanced conduction disease.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>\n              In this multicenter study, 48 patients with either nonspecific interventricular conduction delay (n=29) or left bundle branch block (n=19) underwent acute hemodynamic testing to determine the change in left ventricular pressure maximal first derivative (LV d\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \/d\n              <jats:italic toggle=\"yes\">t<\/jats:italic>\n              <jats:sub>max<\/jats:sub>\n              ) from baseline atrial pacing to BVP, LBBAP, or LOT-CRT.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              Atrioventricular-optimized increases in LV d\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \/d\n              <jats:italic toggle=\"yes\">t<\/jats:italic>\n              <jats:sub>max<\/jats:sub>\n              for LOT-CRT (mean, 25.8% [95% CI, 20.9%\u201330.7%]) and BVP (26.4% [95% CI, 20.2%\u201332.6%]) were greater than unipolar LBBAP (19.3% [95% CI, 15.0%\u201323.7%]) or bipolar LBBAP (16.4% [95% CI, 12.7%\u201320.0%];\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \u22640.005). QRS shortening was greater in LOT-CRT (29.5 [95% CI, 23.4\u201335.6] ms) than unipolar LBBAP (11.9 [95% CI, 6.1\u201317.7] ms), bipolar LBBAP (11.7 ms [95% CI, 6.4\u201317.0]), or BVP (18.5 [95% CI, 11.0\u201325.9] ms), all\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \u22640.005. Compared with patients with left bundle branch block, patients with interventricular conduction delay experienced less QRS reduction (\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              =0.026) but similar improvements in LV d\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \/d\n              <jats:italic toggle=\"yes\">t<\/jats:italic>\n              <jats:sub>max<\/jats:sub>\n              (\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              =0.29). Bipolar LBBAP caused anodal capture in 54% of patients and resulted in less LV d\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \/d\n              <jats:italic toggle=\"yes\">t<\/jats:italic>\n              <jats:sub>max<\/jats:sub>\n              improvement than unipolar LBBAP (18.6% versus 23.7%;\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              &lt;0.001). Subclassification of LBBAP capture (European Heart Rhythm Association criteria) indicated LBBAP or LV septal pacing in 27 patients (56%) and deep septal pacing in 21 patients (44%). The hemodynamic benefit of adding left ventricular coronary vein pacing to LBBAP depended on baseline QRS duration (\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              =0.031) and success of LBBAP (\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              &lt;0.004): LOT-CRT provided 14.5% (5.0%\u201324.1%) greater LV d\n              <jats:italic toggle=\"yes\">P<\/jats:italic>\n              \/d\n              <jats:italic toggle=\"yes\">t<\/jats:italic>\n              <jats:sub>max<\/jats:sub>\n              improvement and 20.8 (12.8\u201328.8) ms greater QRS shortening than LBBAP in subjects with QRS \u2265171 ms and deep septal pacing capture type.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>In a CRT cohort with advanced conduction disease, LOT-CRT and BVP provided greater acute hemodynamic benefit than LBBAP. Subjects with wider QRS or deep septal pacing are more likely to benefit from the addition of a left ventricular coronary vein lead to implement LOT-CRT.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>REGISTRATION:<\/jats:title>\n            <jats:p>\n              URL:\n              <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.clinicaltrials.gov\">https:\/\/www.clinicaltrials.gov<\/jats:ext-link>\n              ; Unique identifier: NCT04905290.\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1161\/circep.124.013059","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T09:00:29Z","timestamp":1729674029000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":60,"title":["Multicenter Hemodynamic Assessment of the LOT-CRT Strategy: When Does Combining Left Bundle Branch Pacing and Coronary Venous Pacing Enhance Resynchronization?: Primary Results of the CSPOT Study"],"prefix":"10.1161","volume":"17","clinical-trial-number":[{"clinical-trial-number":"nct04905290","registry":"10.18810\/clinical-trials-gov"}],"author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3318-6601","authenticated-orcid":true,"given":"Marek","family":"Jastrz\u0119bski","sequence":"first","affiliation":[{"name":"First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College, Krakow, Poland (M.J.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4856-832X","authenticated-orcid":true,"given":"Paul","family":"Foley","sequence":"additional","affiliation":[{"name":"Wiltshire Cardiac Center, Great Western Hospital, Swindon, United Kingdom (P.F., B.C.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2265-0501","authenticated-orcid":true,"given":"Badrinathan","family":"Chandrasekaran","sequence":"additional","affiliation":[{"name":"Wiltshire Cardiac Center, Great Western Hospital, Swindon, United Kingdom (P.F., B.C.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2775-5126","authenticated-orcid":true,"given":"Zachary","family":"Whinnett","sequence":"additional","affiliation":[{"name":"Division of Cardiology, National Heart and Lung Institute, Imperial College, London, United Kingdom (Z.W.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2230-100X","authenticated-orcid":true,"given":"Pugazhendhi","family":"Vijayaraman","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, PA (P.V.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3493-2100","authenticated-orcid":true,"given":"Gaurav A.","family":"Upadhyay","sequence":"additional","affiliation":[{"name":"Center for Arrhythmia Care, Section of Cardiology, University of Chicago, Pritzker School of Medicine, IL (G.A.U.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8608-7247","authenticated-orcid":true,"given":"Robert D.","family":"Schaller","sequence":"additional","affiliation":[{"name":"Section of Cardiac Electrophysiology, Cardiovascular Division, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia (R.D.S.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0002-1955","authenticated-orcid":true,"given":"Rafa\u0142","family":"Gardas","sequence":"additional","affiliation":[{"name":"Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland (R.G.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9772-0308","authenticated-orcid":true,"given":"Travis","family":"Richardson","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine, Vanderbilt Heart, Nashville, TN (T.R.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2869-8382","authenticated-orcid":true,"given":"D\u2019Anne","family":"Kudlik","sequence":"additional","affiliation":[{"name":"Medtronic, Minneapolis, MN (D.K., R.W.S., P.Z., J.B., R.W.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert W.","family":"Stadler","sequence":"additional","affiliation":[{"name":"Medtronic, Minneapolis, MN (D.K., R.W.S., P.Z., J.B., R.W.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6233-0385","authenticated-orcid":true,"given":"Patrick","family":"Zimmerman","sequence":"additional","affiliation":[{"name":"Medtronic, Minneapolis, MN (D.K., R.W.S., P.Z., J.B., R.W.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-1022-8998","authenticated-orcid":true,"given":"James","family":"Burrell","sequence":"additional","affiliation":[{"name":"Medtronic, Minneapolis, MN (D.K., R.W.S., P.Z., J.B., R.W.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2790-2305","authenticated-orcid":true,"given":"Robert","family":"Waxman","sequence":"additional","affiliation":[{"name":"Medtronic, Minneapolis, MN (D.K., R.W.S., P.Z., J.B., R.W.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6504-3314","authenticated-orcid":true,"given":"Richard N.","family":"Cornelussen","sequence":"additional","affiliation":[{"name":"Medtronic, Bakken Research Center, Maastricht, NL (R.N.C.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0257-8629","authenticated-orcid":true,"given":"Jonathan","family":"Lyne","sequence":"additional","affiliation":[{"name":"Division of Cardiac Electrophysiology, Beacon Hospital (UCD), Dublin, Ireland (J.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8645-4817","authenticated-orcid":true,"given":"Bengt","family":"Herweg","sequence":"additional","affiliation":[{"name":"Division of Cardiology, University of South Florida Morsani College of Medicine and Tampa General Hospital, Tampa, FL (B.H.)."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.120.009261"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2019.09.006"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/jce.15976"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.123.067465"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2021.04.005"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad044"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.06.1178"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa013168"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa032423"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2010.02882.x"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.743120"},{"key":"e_1_3_3_13_2","first-page":"1346","article-title":"QRS prolongation following cardiac resynchronization: incidence, predictors, and outcomes.","volume":"4","author":"Bomb R","year":"2013","unstructured":"Bomb R, Logan J, Madsen R, Sullivan R, Weachter R, Flaker G. QRS prolongation following cardiac resynchronization: incidence, predictors, and outcomes. J Innov Cardiac Rhythm Manag. 2013;4:1346\u20131354.","journal-title":"J Innov Cardiac Rhythm Manag"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2018.10.037"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euab232"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.12.013"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2010.11.010"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2016.11.017"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2012.07.009"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10741-010-9203-5"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2013.01.216"},{"key":"e_1_3_3_22_2","unstructured":"Pinheiro J Bates D Team RC. nlme: Linear and Nonlinear Mixed Effects Models. R package version 31-164. 2023."},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.21105\/joss.01686"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2021.07.057"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/pace.14793"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.122.011761"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2024.04.022"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2019.05.020"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.901267"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2021.06.011"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.117.005912"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.122.011181"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2021.727611"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euab249"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2022.04.023"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2024.03.007"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.04.011"},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.08.015"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2019.11.040"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrcr.2021.10.002"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad050"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2017.02.043"},{"key":"e_1_3_3_43_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10741-019-09834-w"},{"key":"e_1_3_3_44_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euaa264"},{"key":"e_1_3_3_45_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad264"},{"key":"e_1_3_3_46_2","doi-asserted-by":"publisher","DOI":"10.1111\/jce.14910"},{"key":"e_1_3_3_47_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euy254"},{"key":"e_1_3_3_48_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eup364"},{"key":"e_1_3_3_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hroo.2021.01.005"},{"key":"e_1_3_3_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrcr.2022.03.014"}],"container-title":["Circulation: Arrhythmia and Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/CIRCEP.124.013059","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T21:07:40Z","timestamp":1748552860000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/CIRCEP.124.013059"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":49,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,11]]}},"alternative-id":["10.1161\/CIRCEP.124.013059"],"URL":"https:\/\/doi.org\/10.1161\/circep.124.013059","relation":{},"ISSN":["1941-3149","1941-3084"],"issn-type":[{"value":"1941-3149","type":"print"},{"value":"1941-3084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11]]},"assertion":[{"value":"2024-02-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-15","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-10-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}