{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:53:57Z","timestamp":1787018037095,"version":"build-2736575974"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circ: Cardiovascular Imaging"],"published-print":{"date-parts":[[2009,9]]},"abstract":"<jats:p>\n                    <jats:bold>\n                      <jats:italic>Background\u2014<\/jats:italic>\n                    <\/jats:bold>\n                    Prosthetic orifice area, usually calculated by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE), provides important information regarding the hemodynamic performance of aortic bioprostheses. However, both TTE and TEE have limitations; therefore accurate and reproducible determination of the orifice area often remains a challenge. The present study aimed to investigate the feasibility of cardiovascular magnetic resonance (CMR) to assess the orifice areas of aortic bioprostheses.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>\n                      <jats:italic>Methods and Results\u2014<\/jats:italic>\n                    <\/jats:bold>\n                    CMR planimetry of the orifice area was performed in 65 patients (43\/22 stented\/stentless prostheses; mean time since implantation, 3.1\ufffd2.8 years; mean orifice area [TTE], 1.70\ufffd0.43 cm\n                    <jats:sup>2<\/jats:sup>\n                    ; 62 normally functioning prostheses, 2 severe stenoses, and 1 severe regurgitation) in an imaging plane perpendicular to the transprosthetic flow using steady-state free-precession cine imaging under breath-hold conditions on a 1.5-T MR system. CMR results were compared with TTE (continuity equation, n=65) and TEE (planimetry, n=31). CMR planimetry was readily feasible in 80.0%; feasible with limitation in 15.4% because of stent, flow, and sternal wire artifacts; and impossible in 4.6% because of flow artifacts. Correlations of the orifice areas by CMR with TTE (\n                    <jats:italic>r<\/jats:italic>\n                    =0.82) and CMR with TEE (\n                    <jats:italic>r<\/jats:italic>\n                    =0.92) were significant. The average difference between the methods was \u22120.02\ufffd0.24 cm\n                    <jats:sup>2<\/jats:sup>\n                    (TTE) and 0.05\ufffd0.15 cm\n                    <jats:sup>2<\/jats:sup>\n                    (TEE). Agreement was present for stented and stentless devices and independent of orifice size. Intraobserver and interobserver variabilities of CMR planimetry were 6.7\ufffd5.4% and 11.5\ufffd7.8%.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>\n                      <jats:italic>Conclusions\u2014<\/jats:italic>\n                    <\/jats:bold>\n                    The assessment of aortic bioprostheses with normal orifice areas by CMR is technically feasible and provides orifice areas with a close correlation to echocardiography and low observer dependency.\n                  <\/jats:p>","DOI":"10.1161\/circimaging.108.840967","type":"journal-article","created":{"date-parts":[[2009,5,22]],"date-time":"2009-05-22T21:46:38Z","timestamp":1243028798000},"page":"397-404","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":35,"title":["Feasibility of Cardiovascular Magnetic Resonance to Assess the Orifice Area of Aortic Bioprostheses"],"prefix":"10.1161","volume":"2","author":[{"given":"Florian","family":"von Knobelsdorff-Brenkenhoff","sequence":"first","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andre\u0301","family":"Rudolph","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralf","family":"Wassmuth","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steffen","family":"Bohl","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eva Elina","family":"Buschmann","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Abdel-Aty","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rainer","family":"Dietz","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeanette","family":"Schulz-Menger","sequence":"additional","affiliation":[{"name":"From the Franz-Volhard-Klinik for Cardiology, HELIOS Klinikum Berlin Buch, University Medicine Berlin, Charite\u0301 Campus Buch, Berlin, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.85.6.1591841"},{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(90)90280-3"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(01)01991-9"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-8703(96)90459-7"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1067\/mhj.2002.124057"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(03)00707-1"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000095268.47282.a1"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2006.07.003"},{"key":"e_1_3_2_9_2","first-page":"630","volume":"14","year":"2005","unstructured":"Matsue H, Sawa Y, Matsumiya G, Matsuda H, Hamada S. Mid-term results of freestyle aortic stentless bioprosthetic valve: clinical impact of quantitative analysis of in-vivo three-dimensional flow velocity profile by magnetic resonance imaging. J Heart Valve Dis. 2005; 14: 630\u2013636.","journal-title":"J Heart Valve Dis"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.104.521161"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2007.125039"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/ejechocard\/jen303"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02678483"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.108.190748"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2007.05.003"},{"key":"e_1_3_2_16_2","first-page":"I535","volume":"114","year":"2006","unstructured":"Ali A, Halstead JC, Cafferty F, Sharples L, Rose F, Coulden R, Lee E, Dunning J, Argano V, Tsui S. Are stentless valves superior to modern stented valves? A prospective randomized trial. Circulation. 2006; 114: I535\u2013I540.","journal-title":"Circulation"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000133415.37578.E4"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2005.03.039"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.62.5.372"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.58.1.348341"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000085167.67105.32"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.106.631689"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1067\/S0894-7317(03)00638-2"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(90)91145-V"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.78.1.68"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehn022"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2006.110726"},{"key":"e_1_3_2_28_2","first-page":"2148.","volume":"43","year":"2004","unstructured":"Friedrich M, Schulz-Menger J, Dietz R. Magnetic resonance to assess the aortic valve area in aortic stenosis. J Am Coll Cardiol. 2004; 43: 2148.","journal-title":"J Am Coll Cardiol"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1081\/JCMR-120003947"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-006-0437-5"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2443061127"},{"key":"e_1_3_2_32_2","first-page":"49","volume":"4","year":"1995","unstructured":"Grunkemeier GL, Bodnar E. Comparative assessment of bioprosthesis durability in the aortic position. J Heart Valve Dis. 1995; 4: 49\u201355.","journal-title":"J Heart Valve Dis"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(98)01105-9"}],"container-title":["Circulation: Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/CIRCIMAGING.108.840967","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T21:46:02Z","timestamp":1715550362000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/CIRCIMAGING.108.840967"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["10.1161\/CIRCIMAGING.108.840967"],"URL":"https:\/\/doi.org\/10.1161\/circimaging.108.840967","relation":{},"ISSN":["1941-9651","1942-0080"],"issn-type":[{"value":"1941-9651","type":"print"},{"value":"1942-0080","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9]]},"assertion":[{"value":"2009-05-22","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}