{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T19:08:50Z","timestamp":1790708930244,"version":"4.1.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circ: Cardiovascular Imaging"],"published-print":{"date-parts":[[2013,1]]},"abstract":"<jats:sec>\n            <jats:title>Background\u2014<\/jats:title>\n            <jats:p>The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods and Results\u2014<\/jats:title>\n            <jats:p>\n              Using an in vitro model of MR, the effective regurgitant orifice area and regurgitant volume (RVol) were measured by the PISA technique using 2-dimensional (2D) and 3D (automated true 3D PISA) transthoracic echocardiography. The mean anatomic regurgitant orifice area (0.35\u00b10.10 cm\n              <jats:sup>2<\/jats:sup>\n              ) was underestimated to a greater degree by the 2D (0.12\u00b10.05 cm\n              <jats:sup>2<\/jats:sup>\n              ) than the 3D method (0.25\u00b10.10 cm\n              <jats:sup>2<\/jats:sup>\n              ;\n              <jats:italic>P<\/jats:italic>\n              &lt;0.001 for both). Compared with the flowmeter (40\u00b114 mL), the RVol by 2D PISA (20\u00b119 mL) was underestimated (\n              <jats:italic>P<\/jats:italic>\n              &lt;0.001), but the 3D peak (43\u00b116 mL) and integrated PISA-based (38\u00b114 mL) RVol were comparable (\n              <jats:italic>P<\/jats:italic>\n              &gt;0.05 for both). In patients (n=30, functional MR), 3D effective regurgitant orifice area correlated well with cardiac magnetic resonance imaging RVol\n              <jats:italic>r<\/jats:italic>\n              =0.84 and regurgitant fraction\n              <jats:italic>r<\/jats:italic>\n              =0.80. Compared with cardiac magnetic resonance imaging RVol (33\u00b122 mL), the integrated PISA RVol (34\u00b126 mL;\n              <jats:italic>P<\/jats:italic>\n              =0.42) was not significantly different; however, the peak PISA RVol was higher (48\u00b127 mL;\n              <jats:italic>P<\/jats:italic>\n              &lt;0.001). In addition, RVol calculated as the difference in automated mitral and aortic stroke volumes by real-time 3D volume color flow Doppler echocardiography was not significantly different from cardiac magnetic resonance imaging (34\u00b121 versus 33\u00b122 mL;\n              <jats:italic>P<\/jats:italic>\n              =0.33).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions\u2014<\/jats:title>\n            <jats:p>Automated real-time 3D volume color flow Doppler based 3D PISA is more accurate than the 2D PISA method to quantify MR. In patients with functional MR, the 3D RVol by integrated PISA is more accurate than a peak PISA technique. Automated 3D stroke volume measurement can also be used as an adjunctive method to quantify MR severity.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1161\/circimaging.112.980383","type":"journal-article","created":{"date-parts":[[2012,12,6]],"date-time":"2012-12-06T02:00:05Z","timestamp":1354759205000},"page":"125-133","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":126,"title":["Quantification of Chronic Functional Mitral Regurgitation by Automated 3-Dimensional Peak and Integrated Proximal Isovelocity Surface Area and Stroke Volume Techniques Using Real-Time 3-Dimensional Volume Color Doppler Echocardiography"],"prefix":"10.1161","volume":"6","author":[{"given":"Paaladinesh","family":"Thavendiranathan","sequence":"first","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shizhen","family":"Liu","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saurabh","family":"Datta","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjay","family":"Rajagopalan","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Ryan","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen R.","family":"Igo","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew S.","family":"Jackson","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen H.","family":"Little","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathalie","family":"De Michelis","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mani A.","family":"Vannan","sequence":"additional","affiliation":[{"name":"From the Ohio State University, Columbus, OH (P.T., S.L., S.R., T.R., M.A.V.); Siemens Medical Solutions USA Inc, Mountain View, CA (S.D.); The Methodist DeBakey Heart and Vascular Center, Houston, TX (S.R.I., M.S.J., S.H.L); and University of California Irvine, Orange, CA (N.D.M.)."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(03)00335-3"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1093\/ejechocard\/jeq031"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2009.09.029"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-5273(00)00222-9"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2006.09.006"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2007.09.002"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2008.09.004"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2008.09.022"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1067\/mje.2003.37"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.05.028"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00570-1"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2012.05.021"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/ejechocard\/jeq121"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2011.10.004"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2007.08.009"},{"key":"e_1_3_2_17_2","doi-asserted-by":"crossref","unstructured":"Wang Y Georgescu B Datta S Liu S Vannan MA D C. Automatic cardiac flow quantification on 3d volume color doppler data. Biomedical Imaging: From Nano to Macro 2011 IEEE International Symposium. 2011:1688\u20131691.","DOI":"10.1109\/ISBI.2011.5872729"},{"issue":"3","key":"e_1_3_2_18_2","first-page":"512","article-title":"Regurgitation quantification using 3D PISA in volume echocardiography.","volume":"14","author":"Grady L","year":"2011","unstructured":"Grady L, Datta S, Kutter O, Duong C, Wein W, Little SH, Igo SR, Liu S, Vannan M. Regurgitation quantification using 3D PISA in volume echocardiography. Med Image Comput Comput Assist Interv. 2011;14(Pt 3):512\u2013519.","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.92.5.1151"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1080\/01621459.1987.10478551"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2291010898"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(88)92620-4"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1067\/mje.2002.117901"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2006.12.079"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2006.07.010"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2011.06.020"}],"container-title":["Circulation: Cardiovascular Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/CIRCIMAGING.112.980383","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T01:45:18Z","timestamp":1715564718000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/CIRCIMAGING.112.980383"}},"subtitle":["In Vitro and Clinical Validation"],"short-title":[],"issued":{"date-parts":[[2013,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,1]]}},"alternative-id":["10.1161\/CIRCIMAGING.112.980383"],"URL":"https:\/\/doi.org\/10.1161\/circimaging.112.980383","relation":{},"ISSN":["1941-9651","1942-0080"],"issn-type":[{"value":"1941-9651","type":"print"},{"value":"1942-0080","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,1]]},"assertion":[{"value":"2012-09-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-11-27","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-12-05","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}