{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T14:39:11Z","timestamp":1787495951746,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circ: Cardiovascular Interventions"],"published-print":{"date-parts":[[2022,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Two separate ostium secundum atrial septal defects are a challenging substrate for device closure due to lack of a well-described strategy or an adequately evaluated protocol.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This is a prospective study comprising 20 patients with 2 atrial septal defects who underwent device closure. All of them underwent balloon interrogation (BI) of the intervening tissue to decide 1- versus 2-device strategy. During BI, if the flow through both the defects could be stopped completely implying adequate mobility of the separating tissue, a single device strategy was used. The size of the device in this subset was determined by BI diameter. In case the flow persisted, 2 devices were used to close the defects separately.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The mean age was 24\u00b117 years. The main defect size was (mean 14.5 mm\u00b1SD 2.69 mm), whereas the second defect measured (mean 8.5\u00b1SD 3.02 mm). The tissue separating the 2 defects was measured (mean 6.1\u00b1SD 2.6 mm). In 15 of them, based on the BI results, a single device was used successfully to close both the defects without a residual shunt. In the remaining 5 patients, 2 devices were used. There were no complications during the procedure or at follow-up period of 41.9\u00b116.9 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>BI in patients with 2 atrial septal defects is helpful in defining 1- versus 2-device strategies and in choosing the size of the device to be used. Nearly 3\/4 of the patients may get away with a single device for closing both the defects successfully thereby decreasing the cost and complexity of the procedure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1161\/circinterventions.122.012048","type":"journal-article","created":{"date-parts":[[2022,9,20]],"date-time":"2022-09-20T14:00:50Z","timestamp":1663682450000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":6,"title":["Balloon Interrogation of Intervening Tissue: A Novel Method to Decide Strategy for Closing Multiple Atrial Septal Defects"],"prefix":"10.1161","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5000-4005","authenticated-orcid":true,"given":"Bharat","family":"Dalvi","sequence":"first","affiliation":[{"name":"Glenmark Cardiac Centre, Mumbai, India (B.D.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9054-1270","authenticated-orcid":true,"given":"Parag","family":"Bhalgat","sequence":"additional","affiliation":[{"name":"Sujyot Heart Clinic, Mumbai, India (P.B.)."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1017\/s1047951100005369"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0735-1097(03)00589-8"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1187"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0735-1097(02)01862-4"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(99)70013-9"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjms.2016.05.029"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21145"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2008.01.027"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13019-019-0952-5"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2021.628322"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24329"},{"key":"e_1_3_3_13_2","first-page":"E167","article-title":"Approach to percutaneous closure in patients with multiple atrial septal defects.","volume":"20","author":"Tillman T","year":"2008","unstructured":"Tillman, T, Mulingtapang, R, Sullebarger, JT. Approach to percutaneous closure in patients with multiple atrial septal defects. J Invasive Cardiol. 2008;20:E167\u2013E170. https:\/\/pubmed.ncbi.nlm.nih.gov\/18460721\/","journal-title":"J Invasive Cardiol"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22435"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.10753"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/(sici)1097-0304(199811)45:3<257::aid-ccd8>3.0.co;2-u"},{"key":"e_1_3_3_17_2","first-page":"262","article-title":"Catheter closure of perforated secundum atrial septal defect under intracardiac echocardiographic guidance using a single amplatzer device: feasibility of a new method.","volume":"17","author":"Zanchetta M","year":"2005","unstructured":"Zanchetta, M, Rigatelli, G, Pedon, L, Zennaro, M, Carrozza, A, Onorato, E. Catheter closure of perforated secundum atrial septal defect under intracardiac echocardiographic guidance using a single amplatzer device: feasibility of a new method. J Invasive Cardiol. 2005;17:262\u2013265. https:\/\/pubmed.ncbi.nlm.nih.gov\/15879606\/","journal-title":"J Invasive Cardiol"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40119-012-0009-5"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.4070\/kcj.2011.41.9.549"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1053\/euhj.1999.1909"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.15761\/CDM.1000180"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2018.02.19"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-726x(200102)52:2<203::aid-ccd1048>3.0.co;2-p"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-003-0610-4"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-007-9079-x"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.4103\/apc.APC_69_20"},{"key":"e_1_3_3_27_2","volume-title":"Product Manual: Amplatzer multifenestrated septal occluder- \u201cCribriform\u201d","author":"St Jude Medical (Abbott structural).","unstructured":"St Jude Medical (Abbott structural). Product Manual: Amplatzer multifenestrated septal occluder- \u201cCribriform\u201d. Instructions for Use; Accessed July 13, 2020. https:\/\/manuals.sjm.com\/~\/media\/manuals\/product-manual-pdfs\/1\/9\/19317d63-3146-4382-927f-a27e2d85ea89.pdf"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.754069"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0735-1097(02)01711-4"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22170"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0735-1097(85)80228-x"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2015.06.052"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ppedcard.2020.101263"}],"container-title":["Circulation: Cardiovascular Interventions"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/CIRCINTERVENTIONS.122.012048","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T22:36:18Z","timestamp":1715553378000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/CIRCINTERVENTIONS.122.012048"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9]]},"references-count":32,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2022,9]]}},"alternative-id":["10.1161\/CIRCINTERVENTIONS.122.012048"],"URL":"https:\/\/doi.org\/10.1161\/circinterventions.122.012048","relation":{},"ISSN":["1941-7640","1941-7632"],"issn-type":[{"value":"1941-7640","type":"print"},{"value":"1941-7632","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9]]},"assertion":[{"value":"2022-03-17","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-19","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-09-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}