{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T01:38:58Z","timestamp":1791337138316,"version":"4.3.1"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[2005,8,9]]},"abstract":"<jats:p>\n            <jats:bold>\n              <jats:italic>Background\u2014<\/jats:italic>\n            <\/jats:bold>\n            Patients with heart failure are frequently hospitalized for fluid overload. A reliable method for chronic monitoring of fluid status is therefore desirable. We evaluated an implantable system capable of measuring intrathoracic impedance to identify potential fluid overload before heart failure hospitalization and to determine the correlation between intrathoracic impedance and standard measures of fluid status during hospitalization.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Methods and Results\u2014<\/jats:italic>\n            <\/jats:bold>\n            Thirty-three patients with NYHA class III and IV heart failure were implanted with a special pacemaker in the left pectoral region and a defibrillation lead in the right ventricle. Intrathoracic impedance was regularly measured and recorded between the lead and the pacemaker case. During hospitalizations, pulmonary capillary wedge pressure and fluid status were monitored. Ten patients were hospitalized for fluid overload 25 times over 20.7\u00b18.4 months. Intrathoracic impedance decreased before each admission by an average of 12.3\u00b15.3% (\n            <jats:italic>P<\/jats:italic>\n            &lt;0.001) over an average of 18.3\u00b110.1 days. Impedance reduction began 15.3\u00b110.6 days (\n            <jats:italic>P<\/jats:italic>\n            &lt;0.001) before the onset of worsening symptoms. There was an inverse correlation between intrathoracic impedance and pulmonary capillary wedge pressure (\n            <jats:italic>r<\/jats:italic>\n            =\u22120.61,\n            <jats:italic>P<\/jats:italic>\n            &lt;0.001) and between intrathoracic impedance and net fluid loss (\n            <jats:italic>r<\/jats:italic>\n            =\u22120.70,\n            <jats:italic>P<\/jats:italic>\n            &lt;0.001) during hospitalization. Automated detection of impedance decreases was 76.9% sensitive in detecting hospitalization for fluid overload, with 1.5 false-positive (threshold crossing without hospitalization) detections per patient-year of follow-up.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Conclusions\u2014<\/jats:italic>\n            <\/jats:bold>\n            Intrathoracic impedance is inversely correlated with pulmonary capillary wedge pressure and fluid balance and decreased before the onset of patient symptoms and before hospital admission for fluid overload. Regular monitoring of impedance may provide early warning of impending decompensation and diagnostic information for titration of medication.\n          <\/jats:p>","DOI":"10.1161\/circulationaha.104.492207","type":"journal-article","created":{"date-parts":[[2005,8,2]],"date-time":"2005-08-02T00:25:12Z","timestamp":1122942312000},"page":"841-848","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":631,"title":["Intrathoracic Impedance Monitoring in Patients With Heart Failure"],"prefix":"10.1161","volume":"112","author":[{"given":"Cheuk-Man","family":"Yu","sequence":"first","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Wang","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elaine","family":"Chau","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raymond Hon-Wah","family":"Chan","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shun-Ling","family":"Kong","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Man-Oi","family":"Tang","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jill","family":"Christensen","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert W.","family":"Stadler","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chu-Pak","family":"Lau","sequence":"additional","affiliation":[{"name":"From the Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong (C.-M.Y., S.L.-K.); Medtronic, Inc, Minneapolis, Minn (L.W., J.C., R.W.S.); Grantham Hospital, Hong Kong (E.C.); and Division of Cardiology, Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong (R.H.-W.C., M.-D.T., C.-P.L.)."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","unstructured":"Heart Disease and Stroke Statistics\u20142004 Update. Dallas Tex: American Heart Association; 2003."},{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0147-9563(97)90053-4"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.4037\/ajcc1998.7.3.168"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1388-9842(01)00198-2"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.104.24.2996"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-8703(03)00393-4"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1388-9842(03)00160-0"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-8703(73)90529-2"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.65.1.35"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/31\/4\/008"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.64.5.597"},{"key":"e_1_3_2_12_2","first-page":"260","volume":"66","year":"1969","unstructured":"Pomerantz M, Baumgartner R, Lauridson J, Eiseman B. Transthoracic electrical impedance for the early detection of pulmonary edema. Surgery. 1969; 66: 260\u2013268.","journal-title":"Surgery"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.40009.x"},{"key":"e_1_3_2_14_2","unstructured":"Combs W Wahlstrand J Petersen-Stejskal S. Technical implementation and clinical experience with Legend Plus: a dual sensor SSIR pacemaker. In: Winter U Klocke R Kubicek W Niederlag W eds. Thoracic Impedance Measurements in Clinical Cardiology. New York NY: Thieme Medical Publishers Inc; 1994: 240\u2013248."},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000139841.42454.78"},{"key":"e_1_3_2_16_2","first-page":"671","volume":"58","year":"1975","unstructured":"Ramos MU, LaBree JW, Remole W, Kubicek WG. Transthoracic electric impedance: a clinical guide of pulmonary fluid accumulation in congestive heart failure. Minn Med. 1975; 58: 671\u2013676.","journal-title":"Minn Med"},{"key":"e_1_3_2_17_2","first-page":"410","volume":"9","year":"1974","unstructured":"Kubicek WG, Kottke J, Ramos MU, Patterson RP, Witsoe DA, Labree JW, Remole W, Layman TE, Schoening H, Garamela JT. The Minnesota impedance cardiograph: theory and application. Biomed Eng. 1974; 9: 410\u2013416.","journal-title":"Biomed Eng"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1995.tb04110.x"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1991.tb03349.x"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1388-9842(99)00054-9"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-6757(88)90151-9"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02441608"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1970.tb17733.x"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02478741"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200106000-00008"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013168"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.289.20.2685"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013474"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa032423"}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/CIRCULATIONAHA.104.492207","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T04:31:00Z","timestamp":1715574660000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/CIRCULATIONAHA.104.492207"}},"subtitle":["Correlation With Fluid Status and Feasibility of Early Warning Preceding Hospitalization"],"short-title":[],"issued":{"date-parts":[[2005,8,9]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,8,9]]}},"alternative-id":["10.1161\/CIRCULATIONAHA.104.492207"],"URL":"https:\/\/doi.org\/10.1161\/circulationaha.104.492207","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,8,9]]},"assertion":[{"value":"2005-08-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}