{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,19]],"date-time":"2026-04-19T09:02:43Z","timestamp":1776589363986,"version":"3.51.2"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Circulation"],"published-print":{"date-parts":[[2006,2,7]]},"abstract":"<jats:p>\n            <jats:bold>\n              <jats:italic>Background\u2014<\/jats:italic>\n            <\/jats:bold>\n            We proposed a novel therapeutic strategy against central baroreflex failure: implementation of an artificial baroreflex system to automatically regulate sympathetic vasomotor tone, ie, a bionic baroreflex system (BBS), and we tested its efficacy in a model of sudden hypotension during surgery.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Methods and Results\u2014<\/jats:italic>\n            <\/jats:bold>\n            The BBS consisted of a computer-controlled negative-feedback circuit that sensed arterial pressure (AP) and automatically computed the frequency (STM) of a pulse train required to stimulate sympathetic nerves via an epidural catheter placed at the level of the lower thoracic spinal cord. An operation rule was subsequently designed for the BBS using a feedback correction with proportional and integral gain factors. The transfer function from STM to AP was identified by a white noise system identification method in 12 sevoflurane-anesthetized patients undergoing orthopedic surgery involving the cervical vertebrae, and the feedback correction factors were determined with a numerical simulation to enable the BBS to quickly and stably attenuate an external disturbance on AP. The performance of the designed BBS was then examined in a model of orthostatic hypotension during knee joint surgery (n=21). Without the implementation of the BBS, a sudden deflation of a thigh tourniquet resulted in a 17\u00b13 mm Hg decrease in AP within 10 seconds and a 25\u00b12 mm Hg decrease in AP within 50 seconds. By contrast, during real-time execution of the BBS, the decrease in AP was 9\u00b12 mm Hg at 10 seconds and 1\u00b12 mm Hg at 50 seconds after the deflation.\n          <\/jats:p>\n          <jats:p>\n            <jats:bold>\n              <jats:italic>Conclusions\u2014<\/jats:italic>\n            <\/jats:bold>\n            These results suggest the feasibility of a BBS approach for central baroreflex failure.\n          <\/jats:p>","DOI":"10.1161\/circulationaha.105.587915","type":"journal-article","created":{"date-parts":[[2006,2,6]],"date-time":"2006-02-06T21:58:11Z","timestamp":1139263091000},"page":"634-639","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":29,"title":["Artificial Baroreflex"],"prefix":"10.1161","volume":"113","author":[{"given":"Fumiyasu","family":"Yamasaki","sequence":"first","affiliation":[{"name":"From the Departments of Cardiovascular Control (F.Y., M.A., T.S.), Clinical Laboratory (F.Y.), Orthopedic Surgery (T.U.), and Anesthesiology (T.Y., K.Y.), Kochi Medical School, Nankoku, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Ushida","sequence":"additional","affiliation":[{"name":"From the Departments of Cardiovascular Control (F.Y., M.A., T.S.), Clinical Laboratory (F.Y.), Orthopedic Surgery (T.U.), and Anesthesiology (T.Y., K.Y.), Kochi Medical School, Nankoku, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Yokoyama","sequence":"additional","affiliation":[{"name":"From the Departments of Cardiovascular Control (F.Y., M.A., T.S.), Clinical Laboratory (F.Y.), Orthopedic Surgery (T.U.), and Anesthesiology (T.Y., K.Y.), Kochi Medical School, Nankoku, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Motonori","family":"Ando","sequence":"additional","affiliation":[{"name":"From the Departments of Cardiovascular Control (F.Y., M.A., T.S.), Clinical Laboratory (F.Y.), Orthopedic Surgery (T.U.), and Anesthesiology (T.Y., K.Y.), Kochi Medical School, Nankoku, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koichi","family":"Yamashita","sequence":"additional","affiliation":[{"name":"From the Departments of Cardiovascular Control (F.Y., M.A., T.S.), Clinical Laboratory (F.Y.), Orthopedic Surgery (T.U.), and Anesthesiology (T.Y., K.Y.), Kochi Medical School, Nankoku, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Sato","sequence":"additional","affiliation":[{"name":"From the Departments of Cardiovascular Control (F.Y., M.A., T.S.), Clinical Laboratory (F.Y.), Orthopedic Surgery (T.U.), and Anesthesiology (T.Y., K.Y.), Kochi Medical School, Nankoku, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"e_1_3_2_1_2","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.ph.34.030172.000305"},{"key":"e_1_3_2_2_2","first-page":"37","volume":"21","year":"1995","unstructured":"Robertson D. Diagnosis and management of baroreflex failure. Primary Cardiol. 1995; 21: 37\u201340.","journal-title":"Primary Cardiol"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.2001.tb03687.x"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000017186.52382.f4"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1999.276.6.H2251"},{"key":"e_1_3_2_6_2","first-page":"511","volume":"3","year":"1960","unstructured":"Shy M, Drager GA. A neurological syndrome associated with orthostatic hypotension: a clinico-pathologic study. Arch Neurol. 1960; 3: 511\u2013527.","journal-title":"Arch Neurol"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.46.5.1470"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-125-1-199607010-00012"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199703063361004"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.50.8.1063"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.1997.01900040080012"},{"key":"e_1_3_2_12_2","first-page":"293","volume":"18","year":"1980","unstructured":"Frankel HL, Mathias CJ. Severe hypertension in patients with high spinal cord lesions undergoing electro-ejaculation: management with prostaglandin E2. Paraplegia. 1980; 18: 293\u2013299.","journal-title":"Paraplegia"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.sc.3100488"},{"key":"e_1_3_2_14_2","first-page":"331","volume":"104","year":"1984","unstructured":"Wilcox CS, Puritz R, Lightman SL, Bannister R, Aminoff MJ. Plasma volume regulation in patients with progressive autonomic failure during changes in salt intake or posture. J Lab Clin Med. 1984; 104: 331\u2013339.","journal-title":"J Lab Clin Med"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000126283.99195.37"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0954-6820.1983.tb08574.x"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/109.2.345"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.38.7.1091"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.85.2.1346511"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1161\/circ.100.3.299"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000024101.77521.4d"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00162.2004"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1976.sp011614"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1152\/ajpcell.1977.232.1.C67"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1152\/ajpregu.1999.276.1.R203"},{"key":"e_1_3_2_26_2","doi-asserted-by":"crossref","unstructured":"Marmarelis PZ Marmarelis VZ. Analysis of Physiological Systems: The White-Noise Approach. New York NY: Plenum; 1978.","DOI":"10.1007\/978-1-4613-3970-0"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1253\/jcj.63.945"},{"key":"e_1_3_2_28_2","first-page":"110","volume":"77","year":"1993","unstructured":"Shimoji K, Hokari T, Kano T, Tomita M, Kimura R, Watanabe S, Endoh H, Fukuda S, Fujiwara N, Aida S. Management of intractable pain with percutaneous epidural spinal cord stimulation: differences in pain-relieving effects among diseases and sites of pain. Anesth Analg. 1993; 77: 110\u2013116.","journal-title":"Anesth Analg"},{"key":"e_1_3_2_29_2","first-page":"228","volume":"17","year":"1992","unstructured":"Kahn RL, Marino V, Urquhart B, Sharrock NE. Hemodynamic changes associated with tourniquet use under epidural anesthesia for total knee arthroplasty. Reg Anesth. 1992; 17: 228\u2013232.","journal-title":"Reg Anesth"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000637-199306000-00017"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-097X.1987.tb00164.x"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/82.3.350"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200212000-00029"}],"container-title":["Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/CIRCULATIONAHA.105.587915","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T05:01:43Z","timestamp":1715576503000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/CIRCULATIONAHA.105.587915"}},"subtitle":["Clinical Application of a Bionic Baroreflex System"],"short-title":[],"issued":{"date-parts":[[2006,2,7]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2006,2,7]]}},"alternative-id":["10.1161\/CIRCULATIONAHA.105.587915"],"URL":"https:\/\/doi.org\/10.1161\/circulationaha.105.587915","relation":{},"ISSN":["0009-7322","1524-4539"],"issn-type":[{"value":"0009-7322","type":"print"},{"value":"1524-4539","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,2,7]]},"assertion":[{"value":"2006-02-07","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}