{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T10:44:27Z","timestamp":1794480267802,"version":"4.9.1"},"reference-count":54,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Hypertension"],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:p>\n            Self-home blood pressure (BP) monitoring is recommended to guide clinical decisions on hypertension and is used worldwide for cardiovascular risk management. People usually make their own decisions when purchasing BP devices, which can be made online. If patients purchase nonvalidated devices (those not proven accurate according to internationally accepted standards), hypertension management may be based on inaccurate readings resulting in under- or over-diagnosis or treatment. This study aimed to evaluate the number, type, percentage validated, and cost of home BP devices available online. A search of online businesses selling devices for home BP monitoring was conducted. Multinational companies make worldwide deliveries, so searches were restricted to BP devices available for one nation (Australia) as an example of device availability through the global online marketplace. Validation status of BP devices was determined according to established protocols. Fifty nine online businesses, selling 972 unique BP devices were identified. These included 278 upper-arm cuff devices (18.3% validated), 162 wrist-cuff devices (8.0% validated), and 532 wrist-band wearables (0% validated). Most BP devices (92.4%) were stocked by international e-commerce businesses (eg, eBay, Amazon), but only 5.5% were validated. Validated cuff BP devices were more expensive than nonvalidated devices: median (interquartile range) of 101.1 (75.0\u2013151.5) versus 67.4 (30.4\u2013112.8) Australian Dollars. Nonvalidated BP devices dominate the online marketplace and are sold at lower cost than validated ones, which is a major barrier to accurate home BP monitoring and cardiovascular risk management. Before purchasing a BP device, people should check it has been validated at\n            <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.stridebp.org\">https:\/\/www.stridebp.org<\/jats:ext-link>\n            .\n          <\/jats:p>","DOI":"10.1161\/hypertensionaha.120.14719","type":"journal-article","created":{"date-parts":[[2020,4,10]],"date-time":"2020-04-10T14:30:34Z","timestamp":1586529034000},"page":"1593-1599","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":109,"title":["Nonvalidated Home Blood Pressure Devices Dominate the Online Marketplace in Australia"],"prefix":"10.1161","volume":"75","author":[{"given":"Dean S.","family":"Picone","sequence":"first","affiliation":[{"name":"From the Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (D.S.P., R.A.D., M.G.S., R.F., J.E.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rewati A.","family":"Deshpande","sequence":"additional","affiliation":[{"name":"From the Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (D.S.P., R.A.D., M.G.S., R.F., J.E.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin G.","family":"Schultz","sequence":"additional","affiliation":[{"name":"From the Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (D.S.P., R.A.D., M.G.S., R.F., J.E.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo","family":"Fonseca","sequence":"additional","affiliation":[{"name":"From the Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (D.S.P., R.A.D., M.G.S., R.F., J.E.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norm R.C.","family":"Campbell","sequence":"additional","affiliation":[{"name":"Department of Medicine, Physiology and Pharmacology and Community Health Sciences, O\u2019Brien Institute for Public Health and Libin Cardiovascular Institute of Alberta, University of Calgary, Canada (N.R.C.C.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Delles","sequence":"additional","affiliation":[{"name":"Institute of Cardiovascular and Medical Sciences, University of Glasgow, United Kingdom (C.D.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Hecht Olsen","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Holbaek Hospital, Denmark (M.H.-O.)"},{"name":"Centre for Individualized Medicine in Arterial Diseases, Odense University Hospital, University of Southern Denmark (M.H.-O.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aletta E.","family":"Schutte","sequence":"additional","affiliation":[{"name":"The George Institute for Global Health, University of New South Wales, Sydney, Australia (A.E.S.)"},{"name":"Medical Research Council Unit for Hypertension and Cardiovascular Disease, North-West University, Potchefstroom, South Africa (A.E.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Stergiou","sequence":"additional","affiliation":[{"name":"Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Greece (G.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj","family":"Padwal","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Alberta, Edmonton, Canada (R.P.)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin-Hua","family":"Zhang","sequence":"additional","affiliation":[{"name":"World Hypertension League (X.-H.Z.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James E.","family":"Sharman","sequence":"additional","affiliation":[{"name":"From the Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (D.S.P., R.A.D., M.G.S., R.F., J.E.S.)"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(17)32366-8"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(15)01225-8"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e32834e4aed"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.0000215363.69793.bb"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)30309-X"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.11.006"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001940"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.10.069"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000002246"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283262f31"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000121"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13294"},{"key":"e_1_3_3_14_2","unstructured":"Medaval Ltd. Blood pressure monitors. 2020;2020"},{"key":"e_1_3_3_15_2","first-page":"S43","article-title":"The british hypertension society protocol for the evaluation of blood pressure measuring devices.","volume":"11","author":"O\u2019Brien E","year":"1993","unstructured":"O\u2019Brien, E, Petrie, J, Littler, W, de Swiet, M, Padfield, PL, Altman, DG, Bland, M, Coats, A, Atkins, N. The british hypertension society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11:S43\u2013S62","journal-title":"J Hypertens"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200202000-00002"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283360e98"},{"key":"e_1_3_3_18_2","unstructured":"Association for the Advancement of Medical Instrumentation. American national standard non-invasive sphygmomanometers \u2013 part 2: Clinical validation of automated measurement type iso 81060-2\/ansi-aami. 2013"},{"key":"e_1_3_3_19_2","first-page":"45","article-title":"[Conscientious evaluation of measuring accuracy. Hypertension League provides approval seals for automatic blood pressure units].","volume":"141","author":"Tholl U","year":"1999","unstructured":"Tholl, U, Anlauf, M. [Conscientious evaluation of measuring accuracy. Hypertension League provides approval seals for automatic blood pressure units]. MMW Fortschr Med. 1999;141:45.","journal-title":"MMW Fortschr Med"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/mbp.0b013e32809efa27"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000020"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000100"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000257"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000266"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mbp.0000168400.71920.9a"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283638f04"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e32835b9ecb"},{"key":"e_1_3_3_28_2","first-page":"55","article-title":"Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175.","volume":"1","author":"O\u2019Brien E","year":"1996","unstructured":"O\u2019Brien, E, Mee, F, Atkins, N, Thomas, M. Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175. Blood Press Monit. 1996;1:55\u201361.","journal-title":"Blood Press Monit"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0212-6567(00)78470-8"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1590\/s0066-782x2005000500003"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.2147\/VHRM.S72438"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000096"},{"key":"e_1_3_3_33_2","first-page":"389","article-title":"Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension.","volume":"3","author":"Belghazi J","year":"2007","unstructured":"Belghazi, J, El Feghali, RN, Moussalem, T, Rejdych, M, Asmar, RG. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vasc Health Risk Manag. 2007;3:389\u2013400.","journal-title":"Vasc Health Risk Manag"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000186"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.2147\/VHRM.S27193"},{"key":"e_1_3_3_36_2","first-page":"29","article-title":"Validation of home blood pressure-monitoring devices omron evolv (hem-7600t-e), hem-9210t, and m3 comfort (hem-7134-e) according to european society of hypertension international protocol (esh-ip) revision 2010.","volume":"48","author":"Takahashi H","year":"2018","unstructured":"Takahashi, H. Validation of home blood pressure-monitoring devices omron evolv (hem-7600t-e), hem-9210t, and m3 comfort (hem-7134-e) according to european society of hypertension international protocol (esh-ip) revision 2010. Jpn J Clin Physiol. 2018;48:29\u201338.","journal-title":"Jpn J Clin Physiol"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000078"},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.3109\/08037050903262496"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.2147\/MDER.S142126"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000278"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mbp.0000217995.12215.f2"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283624aa2"},{"key":"e_1_3_3_43_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000234"},{"key":"e_1_3_3_44_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000256"},{"key":"e_1_3_3_45_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000017"},{"key":"e_1_3_3_46_2","doi-asserted-by":"publisher","DOI":"10.2147\/VHRM.S44569"},{"key":"e_1_3_3_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2018.02.022"},{"key":"e_1_3_3_48_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000000673"},{"key":"e_1_3_3_49_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000279"},{"key":"e_1_3_3_50_2","first-page":"1","article-title":"Ieee standard for wearable cuffless blood pressure measuring devices.","volume":"1708","author":"Institute of Electrical and Electronics Engineers","year":"2014","unstructured":"Institute of Electrical and Electronics Engineers. Ieee standard for wearable cuffless blood pressure measuring devices. IEEE Standard 1708-2014. 2014;IEEE Standard 1708-2014:1\u201338.","journal-title":"IEEE Standard 1708-2014"},{"key":"e_1_3_3_51_2","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2016.101"},{"key":"e_1_3_3_52_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200504000-00009"},{"key":"e_1_3_3_53_2","doi-asserted-by":"publisher","DOI":"10.1111\/jch.12782"},{"key":"e_1_3_3_54_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.118.11990"},{"key":"e_1_3_3_55_2","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13499"}],"container-title":["Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/HYPERTENSIONAHA.120.14719","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T10:05:43Z","timestamp":1715594743000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/HYPERTENSIONAHA.120.14719"}},"subtitle":["Major Implications for Cardiovascular Risk Management"],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":54,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["10.1161\/HYPERTENSIONAHA.120.14719"],"URL":"https:\/\/doi.org\/10.1161\/hypertensionaha.120.14719","relation":{},"ISSN":["0194-911X","1524-4563"],"issn-type":[{"value":"0194-911X","type":"print"},{"value":"1524-4563","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6]]},"assertion":[{"value":"2020-01-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-02-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-04-10","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}