{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T22:24:34Z","timestamp":1787783074289,"version":"build-2784847793"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["Hypertension"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND:<\/jats:title>\n            <jats:p>Automated blood pressure (BP) devices may be less accurate in females than males, but this requires further investigation. This study aimed to determine sex differences in automated BP, measured with a single brand and model of device, compared with manual BP, with a focus on cuff sizes and associations with measures of adiposity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Automated (Omron HEM-907XL) and manual BP were taken sequentially in a random order among a subsample of participants attending the US National Health and Nutrition Examination Survey, 2017 to 2018. Anthropometry and dual-energy x-ray absorptiometry were used to record body size and composition. Analyses, including multivariable regression to determine sex differences in BP, by cuff size, followed complex survey statistical principles.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>A total of 3735 participants (49.0% female [95% CI, 46.4\u201351.6], 45 years [43\u201346]) were included. In females, automated systolic BP (SBP) incrementally underestimated manual SBP across larger cuffs up to extra-large (\u20136.4 mm\u2009Hg [\u22128.0 to \u22124.9]). In males, automated SBP underestimated manual SBP only with extra-large cuffs (\u20132.4 mm\u2009Hg [95% CI\u22123.9 to \u22120.9]). Underestimation by automated SBP with extra-large cuffs was independently associated with all measures of body size indicative of increased adiposity in both females and males. Hypertension classification from automated and manual SBP had moderate agreement for adult\/large cuffs (weighted kappa range 0.66\u20130.79) but weak agreement for extra-large cuffs (0.55\u20130.58) for females and males.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>The automated device used in this study underestimated manual SBP at larger cuff sizes, which was associated with indices of adiposity. Poorer accuracy of automated BP in larger cuff sizes could contribute to inequitable BP-related health care for females and males and requires further investigation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1161\/hypertensionaha.124.24640","type":"journal-article","created":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T05:01:09Z","timestamp":1751346069000},"page":"1449-1459","update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":1,"title":["Sex Differences in BP From an Automated Oscillometric Compared With Manual Device"],"prefix":"10.1161","volume":"82","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6357-7307","authenticated-orcid":true,"given":"Tan V.","family":"Bui","sequence":"first","affiliation":[{"name":"Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (T.V.B., J.E.S., N.C., M.G.S., S.L.G., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2792-0811","authenticated-orcid":true,"given":"James E.","family":"Sharman","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (T.V.B., J.E.S., N.C., M.G.S., S.L.G., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6317-5594","authenticated-orcid":true,"given":"Niamh","family":"Chapman","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (T.V.B., J.E.S., N.C., M.G.S., S.L.G., D.S.P.)."},{"name":"School of Health Sciences, Faculty of Medicine and Health, University of Sydney, New South Wales, Australia (N.C., T.L.B., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3458-1811","authenticated-orcid":true,"given":"Martin G.","family":"Schultz","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (T.V.B., J.E.S., N.C., M.G.S., S.L.G., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4170-2784","authenticated-orcid":true,"given":"Jennifer S.","family":"Ringrose","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Alberta, Edmonton, Canada (J.S.R.)."},{"name":"Women and Children\u2019s Health Research Institute, Edmonton, Alberta, Canada (J.S.R.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5138-2526","authenticated-orcid":true,"given":"Seana L.","family":"Gall","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (T.V.B., J.E.S., N.C., M.G.S., S.L.G., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7569-4527","authenticated-orcid":true,"given":"Tomas L.","family":"Bothe","sequence":"additional","affiliation":[{"name":"School of Health Sciences, Faculty of Medicine and Health, University of Sydney, New South Wales, Australia (N.C., T.L.B., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1315-6747","authenticated-orcid":true,"given":"Tammy M.","family":"Brady","sequence":"additional","affiliation":[{"name":"Division of Paediatric Nephrology, Johns Hopkins University School of Medicine, Baltimore, MD (T.M.B.)."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4760-1634","authenticated-orcid":true,"given":"Dean S.","family":"Picone","sequence":"additional","affiliation":[{"name":"Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia (T.V.B., J.E.S., N.C., M.G.S., S.L.G., D.S.P.)."},{"name":"School of Health Sciences, Faculty of Medicine and Health, University of Sydney, New South Wales, Australia (N.C., T.L.B., D.S.P.)."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(20)30752-2"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001197"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1159\/000489855"},{"key":"e_1_3_3_5_2","unstructured":"International Organisation for Standardization. Non-invasive sphygmomanometers part 2: clinical investigation of intermittent automated measurement type. ISO 81060-2:2018(E). 2018. Accessed February 27 2025. https:\/\/www.iso.org\/standard\/73339.html. 2018"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehae178"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.122.19693"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2022.15513"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajh\/hpac003"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000001823"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0b013e32834f98a0"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1038\/hr.2010.146"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-7176.2009.00199.x"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYP.0000000000000087"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.11.006"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocd.2012.03.005"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.120.049360"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamacardio.2019.5306"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.111.184101"},{"key":"e_1_3_3_20_2","unstructured":"American Medical Association. Target:BP. Device accuracy test. Accessed October 27 2024. https:\/\/map.ama-assn.org\/resources\/smbp-device-calibration-test"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e32813fa386"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200208000-00006"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00126097-200104000-00007"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1511939"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41371-022-00693-x"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-24264-9"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1381\/096089202321144513"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2023.2661"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.124.23678"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.hyp.36.4.484"}],"container-title":["Hypertension"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/HYPERTENSIONAHA.124.24640","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T18:33:53Z","timestamp":1759948433000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/HYPERTENSIONAHA.124.24640"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":29,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1161\/HYPERTENSIONAHA.124.24640"],"URL":"https:\/\/doi.org\/10.1161\/hypertensionaha.124.24640","relation":{},"ISSN":["0194-911X","1524-4563"],"issn-type":[{"value":"0194-911X","type":"print"},{"value":"1524-4563","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"2025-01-07","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}