{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T03:13:05Z","timestamp":1786331585315,"version":"build-2736575974"},"reference-count":7,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["JAHA"],"published-print":{"date-parts":[[2014,3,24]]},"abstract":"<jats:sec xml:lang=\"en\">\n            <jats:title>Background<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              Over 140 million\n              <jats:styled-content style=\"fixed-case\">iP<\/jats:styled-content>\n              ads\n              <jats:sup>\u00ae<\/jats:sup>\n              have been sold worldwide. The\n              <jats:styled-content style=\"fixed-case\">iP<\/jats:styled-content>\n              ad2\n              <jats:sup>\u00ae<\/jats:sup>\n              , with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life\u2010threatening situations in patients. The goal of this study was to determine whether the\n              <jats:styled-content style=\"fixed-case\">iP<\/jats:styled-content>\n              ad2\n              <jats:sup>\u00ae<\/jats:sup>\n              can cause electromagnetic interference in patients with implantable cardioverter defibrillators.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec xml:lang=\"en\">\n            <jats:title>Methods and Results<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              Twenty\u2010seven patients with implantable cardioverter defibrillators were studied. The\n              <jats:styled-content style=\"fixed-case\">iP<\/jats:styled-content>\n              ad2\n              <jats:sup>\u00ae<\/jats:sup>\n              was held at reading distance and placed directly over the device with cellular data capability activated and deactivated. The manufacturers\/models of devices and the patients' body mass index were noted. The presence of electromagnetic interference was detected by using a programmer supplied by each manufacturer. Magnet mode with suspension of anti\u2010tachycardia therapy was triggered in 9 (33%) patients. All occurred when the\n              <jats:styled-content style=\"fixed-case\">iP<\/jats:styled-content>\n              ad2\n              <jats:sup>\u00ae<\/jats:sup>\n              was placed directly over the device. The cellular data status did not cause interference and no noise or oversensing was noted. There was no significant difference between the mean body mass index of the groups with or without interference.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec xml:lang=\"en\">\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              The\n              <jats:styled-content style=\"fixed-case\">iP<\/jats:styled-content>\n              ad2\n              <jats:sup>\u00ae<\/jats:sup>\n              can trigger magnet mode in implantable cardioverter defibrillators when laid directly over the device. This is potentially dangerous if patients should develop life\u2010threatening arrhythmias at the same time. As new electronic products that use magnets are produced, the potential risk to patients with implantable defibrillators needs to be addressed.\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1161\/jaha.113.000746","type":"journal-article","created":{"date-parts":[[2014,4,11]],"date-time":"2014-04-11T04:53:40Z","timestamp":1397192020000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":17,"title":["iPad2\n            <sup>\u00ae<\/sup>\n            Use in Patients With Implantable Cardioverter Defibrillators Causes Electromagnetic Interference: The EMIT Study"],"prefix":"10.1161","volume":"3","author":[{"given":"Teri M.","family":"Kozik","sequence":"first","affiliation":[{"name":"Cardiac Research Department,  Stockton, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianna","family":"Chien","sequence":"additional","affiliation":[{"name":"Central Valley Arrhythmia, Stockton, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Therese F.","family":"Connolly","sequence":"additional","affiliation":[{"name":"St. Joseph's Medical Center, Stockton, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gurinder S.","family":"Grewal","sequence":"additional","affiliation":[{"name":"St. Joseph's Medical Center, Stockton, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Liang","sequence":"additional","affiliation":[{"name":"Stanford University School of Medicine, Stanford, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter","family":"Chien","sequence":"additional","affiliation":[{"name":"Central Valley Arrhythmia, Stockton, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1586\/14779072.6.6.823"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eur137"},{"key":"e_1_3_3_4_2","first-page":"79","article-title":"Electromagnetic interference in patients with implanted cardioverter\u2010defibrillators and implantable loop recorders","volume":"2","author":"de Sousa M","year":"2002","unstructured":"de Sousa M, Klein G, Korte T, Niehaus M. Electromagnetic interference in patients with implanted cardioverter\u2010defibrillators and implantable loop recorders. Indian Pacing Eletrophysiol J. 2002;2:79\u201384.","journal-title":"Indian Pacing Eletrophysiol J"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.21998"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.07.003"},{"key":"e_1_3_3_7_2","unstructured":"Boston Scientific . Using a magnet to temporarily inhibit tachy therapy or change tachy therapy to off. A Closer Look: Product Education at a Glance. Available at: http:\/\/www.bostonscientific-international.com\/templatedata\/imports\/HTML\/CRM\/A_Closer_Look\/pdfs\/ACL_Using_Magnet_Inhibit_Change_Tachy_Therapy_030909.pdf. Accessed August 2 2013."},{"key":"e_1_3_3_8_2","unstructured":"Biotronik . Press release 2013. http:\/\/www.biotronik.com\/wps\/wcm\/connect\/int_web\/biotronik\/newsroom\/press_releases\/press_releases. Accessed July 31 2013."}],"updated-by":[{"DOI":"10.1161\/jaha.114.000906","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2014,7,29]],"date-time":"2014-07-29T00:00:00Z","timestamp":1406592000000}}],"container-title":["Journal of the American Heart Association"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/JAHA.113.000746","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T10:30:30Z","timestamp":1715596230000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/JAHA.113.000746"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3,24]]},"references-count":7,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,3,24]]}},"alternative-id":["10.1161\/JAHA.113.000746"],"URL":"https:\/\/doi.org\/10.1161\/jaha.113.000746","relation":{"correction":[{"id-type":"doi","id":"10.1161\/JAHA.114.000906","asserted-by":"object"}]},"ISSN":["2047-9980"],"issn-type":[{"value":"2047-9980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,3,24]]},"assertion":[{"value":"2013-12-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-02-19","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-04-11","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e000746"}}