{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T12:40:43Z","timestamp":1793796043725,"version":"4.6.1"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["JAHA"],"published-print":{"date-parts":[[2016,2,23]]},"abstract":"<jats:sec xml:lang=\"en\">\n            <jats:title>Background<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              Off\u2010pump coronary artery bypass (\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              ) has been shown to reduce the risk of neurologic complications as compared to coronary artery bypass grafting performed with cardiopulmonary bypass. Side\u2010clamping of the aorta while constructing proximal anastomoses, however, still carries substantial risk of cerebral embolization. We aimed to perform a comprehensive meta\u2010analysis of studies assessing 2 clampless techniques: aortic \u201cno\u2010touch\u201d and proximal anastomosis devices (\n              <jats:styled-content style=\"fixed-case\">PAD<\/jats:styled-content>\n              ) for\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              .\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec xml:lang=\"en\">\n            <jats:title>Methods and Results<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              PubMed,\n              <jats:styled-content style=\"fixed-case\">CINAHL<\/jats:styled-content>\n              ,\n              <jats:styled-content style=\"fixed-case\">CENTRAL<\/jats:styled-content>\n              , and Google Scholar databases were screened for randomized controlled trials and observational studies comparing \u201cno\u2010touch\u201d and\/or\n              <jats:styled-content style=\"fixed-case\">PAD<\/jats:styled-content>\n              with side\u2010clamp\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              and reporting short\u2010term (\u226430\u00a0days) outcomes: cerebrovascular accident and all\u2010cause mortality. A total of 18 studies (3 randomized controlled trials) enrolling 25\u00a0163 patients were included. Aortic \u201cno\u2010touch\u201d was associated with statistically lower risk of cerebrovascular accident as compared to side\u2010clamp\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              : risk ratio 95%\n              <jats:styled-content style=\"fixed-case\">CI<\/jats:styled-content>\n              : 0.41 (0.27\u20130.61);\n              <jats:italic>P<\/jats:italic>\n              &lt;0.01; I\n              <jats:sup>2<\/jats:sup>\n              =0%. Event rates were 0.36% and 1.28% for \u201cno\u2010touch\u201d and side\u2010clamp\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              , respectively. No difference was seen between\n              <jats:styled-content style=\"fixed-case\">PAD<\/jats:styled-content>\n              and side\u2010clamp\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              : 0.71 (0.33\u20131.55);\n              <jats:italic>P<\/jats:italic>\n              =0.39; I\n              <jats:sup>2<\/jats:sup>\n              =39%. A\u00a0trend towards increased 30\u2010day all\u2010cause mortality with\n              <jats:styled-content style=\"fixed-case\">PAD<\/jats:styled-content>\n              and no difference with \u201cno\u2010touch\u201d were observed when compared to side\u2010clamp\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              . In a subset analysis, \u201cno\u2010touch\u201d consistently reduced the risk of cerebrovascular accident regardless of patients\u2019 baseline risk characteristics. A benefit with\n              <jats:styled-content style=\"fixed-case\">PAD<\/jats:styled-content>\n              was observed in low\u2010risk patients.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec xml:lang=\"en\">\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              Aortic \u201cno\u2010touch\u201d technique was associated with nearly 60% lower risk of postoperative cerebrovascular events as compared to conventional side\u2010clamp\n              <jats:styled-content style=\"fixed-case\">OPCAB<\/jats:styled-content>\n              with effect consistent across patients at different risk.\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1161\/jaha.115.002802","type":"journal-article","created":{"date-parts":[[2016,2,19]],"date-time":"2016-02-19T04:33:38Z","timestamp":1455856418000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":52,"title":["Cerebrovascular Events After No\u2010Touch Off\u2010Pump Coronary Artery Bypass Grafting, Conventional Side\u2010Clamp Off\u2010Pump Coronary Artery Bypass, and Proximal Anastomotic Devices: A Meta\u2010Analysis"],"prefix":"10.1161","volume":"5","author":[{"given":"Wojciech","family":"Pawliszak","sequence":"first","affiliation":[{"name":"Department of Cardiac Surgery, Dr Antoni Jurasz Memorial University Hospital, Bydgoszcz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariusz","family":"Kowalewski","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Dr Antoni Jurasz Memorial University Hospital, Bydgoszcz, Poland"},{"name":"Division of Ergonomics and Physical Effort, Department of Hygiene, Epidemiology and Ergonomics, Collegium Medicum UMK, Bydgoszcz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe Maria","family":"Raffa","sequence":"additional","affiliation":[{"name":"Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS\u2014ISMETT (Istituto Mediterraneo per I Trapianti e Terapie ad alta specializzazione), Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pietro Giorgio","family":"Malvindi","sequence":"additional","affiliation":[{"name":"Wessex Cardiothoracic Centre, University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magdalena Ewa","family":"Kowalkowska","sequence":"additional","affiliation":[{"name":"Department and Clinic of Obstetrics, Gynecology, and Oncological Gynecology, Collegium Medicum, Bydgoszcz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krzysztof Aleksander","family":"Szwed","sequence":"additional","affiliation":[{"name":"Department of Clinical Neuropsychology, Collegium Medicum, Bydgoszcz, Poland"},{"name":"Nicolaus Copernicus University, Toru\u0144, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alina","family":"Borkowska","sequence":"additional","affiliation":[{"name":"Department of Clinical Neuropsychology, Collegium Medicum, Bydgoszcz, Poland"},{"name":"Nicolaus Copernicus University, Toru\u0144, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janusz","family":"Kowalewski","sequence":"additional","affiliation":[{"name":"Lung Cancer and Thoracic Surgery Department, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University, Toru\u0144, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lech","family":"Anisimowicz","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Dr Antoni Jurasz Memorial University Hospital, Bydgoszcz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(02)02429-3"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamainternmed.2013.12844"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0804626"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1053\/stcs.2002.31897"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2015.08.042"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.g7647"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d5928"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10654-010-9491-z"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d4002"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2007.12.046"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(02)03470-7"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2011.04.031"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.05.019"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(02)04060-2"},{"key":"e_1_3_2_16_2","first-page":"169","article-title":"Improving neurologic outcome in off\u2010pump surgery: the \u201cno touch\u201d technique","volume":"6","author":"Leacche M","year":"2003","unstructured":"Leacche M, Carrier M, Bouchard D, Pellerin M, Perrault LP, Paga P, Hebert Y, Cartier R. Improving neurologic outcome in off\u2010pump surgery: the \u201cno touch\u201d technique. Heart Surg Forum. 2003;6:169\u2013175.","journal-title":"Heart Surg Forum"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2004.06.013"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8191.2009.00911.x"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/MCA.0b013e3283632558"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0030-1249831"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2014.09.011"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(02)03755-4"},{"key":"e_1_3_2_23_2","first-page":"45","article-title":"Should we perform coronary artery revascularization without aortic manipulation more often?","volume":"4","author":"Pawlaczyk R","year":"2011","unstructured":"Pawlaczyk R, Szyndler K, Lango R, Jagielak D, \u0141o\u015b A, Wo\u015b \u0141, Bojar P, Rogowski J. Should we perform coronary artery revascularization without aortic manipulation more often? Kardiochir Torakochirurgia Pol. 2011;4:45\u2013449.","journal-title":"Kardiochir Torakochirurgia Pol"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hlc.2007.11.138"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2007.02.022"},{"key":"e_1_3_2_26_2","first-page":"E607","article-title":"Initial Experience with the Enclose Proximal Aortic Anastomosis Device during Off\u2010Pump Coronary Artery Bypass: An Alternative to Aortic Side Clamping","volume":"9","author":"Boova RS","year":"2006","unstructured":"Boova RS, Trace C, Leshnower BG. Initial Experience with the Enclose Proximal Aortic Anastomosis Device during Off\u2010Pump Coronary Artery Bypass: An Alternative to Aortic Side Clamping. Heart Surg Forum. 2006;9:E607\u2013E611.","journal-title":"Heart Surg Forum"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1093\/icvts\/ivr004"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.01.074"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2005.08.015"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehu278"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.675595"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.05.073"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2009.04.135"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.3109\/15622975.2013.824611"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199612193352501"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2014.10.112"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1412168"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.10.912"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013563"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1067\/mtc.2002.122525"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20238"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000100723.50363.2C"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1415447"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2007.12.002"}],"container-title":["Journal of the American Heart Association"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/JAHA.115.002802","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T10:24:34Z","timestamp":1715595874000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/JAHA.115.002802"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,23]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,2,23]]}},"alternative-id":["10.1161\/JAHA.115.002802"],"URL":"https:\/\/doi.org\/10.1161\/jaha.115.002802","relation":{},"ISSN":["2047-9980"],"issn-type":[{"value":"2047-9980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,2,23]]},"assertion":[{"value":"2015-10-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-11-22","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-02-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e002802"}}