{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T21:52:49Z","timestamp":1793137969041,"version":"4.5.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"16","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["JAHA"],"published-print":{"date-parts":[[2019,8,20]]},"abstract":"<jats:sec xml:lang=\"en\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p xml:lang=\"en\">\n                      Fetal magnetocardiography (\n                      <jats:styled-content style=\"fixed-case\">fMCG<\/jats:styled-content>\n                      ) is a highly effective technique for evaluation of fetuses with life\u2010threatening arrhythmia, but its dissemination has been constrained by the high cost and complexity of Superconducting Quantum Interference Device (SQUID) instrumentation. Optically pumped magnetometers (\n                      <jats:styled-content style=\"fixed-case\">OPM<\/jats:styled-content>\n                      s) are a promising new technology that can replace\n                      <jats:styled-content style=\"fixed-case\">SQUID<\/jats:styled-content>\n                      s for\u00a0many applications. This study compares the performance of an\n                      <jats:styled-content style=\"fixed-case\">fMCG<\/jats:styled-content>\n                      system, utilizing\n                      <jats:styled-content style=\"fixed-case\">OPM<\/jats:styled-content>\n                      s operating in a person\u2010sized magnetic shield, to that of a conventional\n                      <jats:styled-content style=\"fixed-case\">fMCG<\/jats:styled-content>\n                      system, utilizing\n                      <jats:styled-content style=\"fixed-case\">SQUID<\/jats:styled-content>\n                      magnetometers operating in a magnetically shielded room.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec xml:lang=\"en\">\n                    <jats:title>Methods and Results<\/jats:title>\n                    <jats:p xml:lang=\"en\">\n                      <jats:styled-content style=\"fixed-case\">fMCG<\/jats:styled-content>\n                      recordings were made in 24 subjects using the\n                      <jats:styled-content style=\"fixed-case\">SQUID<\/jats:styled-content>\n                      system with the mother lying supine in a magnetically shielded room and the\n                      <jats:styled-content style=\"fixed-case\">OPM<\/jats:styled-content>\n                      system with the mother lying prone in a person\u2010sized, cylindrical shield. Signal\u2010to\u2010noise ratios of the\n                      <jats:styled-content style=\"fixed-case\">OPM<\/jats:styled-content>\n                      and\n                      <jats:styled-content style=\"fixed-case\">SQUID<\/jats:styled-content>\n                      recordings were not statistically different and were adequate for diagnostic purposes with both technologies. Although the environmental noise was higher using the small open\u2010ended shield, this was offset by the higher signal amplitude achieved with prone positioning, which reduced the distance between the fetus and sensors and improved patient comfort. In several subjects,\n                      <jats:styled-content style=\"fixed-case\">fMCG<\/jats:styled-content>\n                      provided a differential diagnosis that was more precise and\/or definitive than was possible with echocardiography alone.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec xml:lang=\"en\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p xml:lang=\"en\">\n                      The\n                      <jats:styled-content style=\"fixed-case\">OPM<\/jats:styled-content>\n                      \u2010based system was portable, improved patient comfort, and performed as well as the\n                      <jats:styled-content style=\"fixed-case\">SQUID<\/jats:styled-content>\n                      \u2010based system at a small fraction of the cost. Electrophysiological assessment of fetal rhythm is now practical and will have a major impact on management of fetuses with long\n                      <jats:styled-content style=\"fixed-case\">QT<\/jats:styled-content>\n                      syndrome and other life\u2010threatening arrhythmias.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1161\/jaha.119.013436","type":"journal-article","created":{"date-parts":[[2019,8,9]],"date-time":"2019-08-09T05:05:32Z","timestamp":1565327132000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":127,"title":["Low\u2010Cost Fetal Magnetocardiography: A Comparison of Superconducting Quantum Interference Device and Optically Pumped Magnetometers"],"prefix":"10.1161","volume":"8","author":[{"given":"Sarah","family":"Strand","sequence":"first","affiliation":[{"name":"Department of Medical Physics University of Wisconsin Madison WI"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Lutter","sequence":"additional","affiliation":[{"name":"Department of Medical Physics University of Wisconsin Madison WI"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janette F.","family":"Strasburger","sequence":"additional","affiliation":[{"name":"Division of Cardiology Department of Pediatrics Children's Hospital of Wisconsin\u2010 Milwaukee Milwaukee WI"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Shah","sequence":"additional","affiliation":[{"name":"QuSpin, Inc. Louisville CO"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oswaldo","family":"Baffa","sequence":"additional","affiliation":[{"name":"Department of Physics FFCLRP Ribeirao Preto, University of Sao Paulo Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald T.","family":"Wakai","sequence":"additional","affiliation":[{"name":"Department of Medical Physics University of Wisconsin Madison WI"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.004840"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2007.06.060"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/nrcardio.2010.32"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2013.04.020"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000437597.44550.5d"},{"key":"e_1_3_1_7_2","first-page":"11","article-title":"Neuromagnetic instrumentation","volume":"54","author":"Fagaly RL","year":"1990","unstructured":"Fagaly RL. Neuromagnetic instrumentation. Adv Neurol. 1990;54:11\u201332.","journal-title":"Adv Neurol"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1038\/nature01484"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2017.08.009"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2011.2160635"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2006.872822"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.2307\/2532051"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(95)00307-X"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.2392722"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa93d1"}],"container-title":["Journal of the American Heart Association"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/JAHA.119.013436","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T07:38:30Z","timestamp":1715585910000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/JAHA.119.013436"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,20]]},"references-count":14,"journal-issue":{"issue":"16","published-print":{"date-parts":[[2019,8,20]]}},"alternative-id":["10.1161\/JAHA.119.013436"],"URL":"https:\/\/doi.org\/10.1161\/jaha.119.013436","relation":{},"ISSN":["2047-9980"],"issn-type":[{"value":"2047-9980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,20]]},"assertion":[{"value":"2019-05-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-07-15","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-08-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e013436"}}