{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T19:05:01Z","timestamp":1789585501993,"version":"build-2803163510"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"13","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["JAHA"],"published-print":{"date-parts":[[2020,7,7]]},"abstract":"<jats:sec xml:lang=\"en\">\n            <jats:title>Background<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              Dual axis rotational coronary angiography (\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              ) reduces radiation exposure during coronary angiography on older x\u2010ray systems. The purpose of the current study is to quantify patient and staff radiation exposure using\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              on a modality already equipped with dose\u2010reducing technology. Additionally, we assessed applicability of 1 dose area product to effective dose conversion factor for both\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              and conventional coronary angiography (\n              <jats:styled-content style=\"fixed-case\">CCA<\/jats:styled-content>\n              ) procedures.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec xml:lang=\"en\">\n            <jats:title>Methods and Results<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              Twenty patients were examined using\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              and were compared with 20 age\u2010, sex\u2010, and body mass index\u2013matched patients selected from a prior study using\n              <jats:styled-content style=\"fixed-case\">CCA<\/jats:styled-content>\n              on the same x\u2010ray modality. All irradiation events are simulated using\n              <jats:styled-content style=\"fixed-case\">PCXMC<\/jats:styled-content>\n              (\n              <jats:styled-content style=\"fixed-case\">STUK<\/jats:styled-content>\n              , Finland) to determine organ and effective doses. Moreover, for\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              each frame is simulated. Staff dose is measured using active personal dosimeters (DoseAware, Philips Healthcare, The Netherlands). With\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              , median cumulative dose area product is reduced by 57% (ie, 7.41 versus 17.19\u00a0Gy\u00b7cm\n              <jats:sup>2<\/jats:sup>\n              ). Effective dose conversion factors of\n              <jats:styled-content style=\"fixed-case\">CCA<\/jats:styled-content>\n              and\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              are slightly different, yet this difference is not statistically significant. The occupational dose at physician's chest, leg, and collar level are reduced by 60%, 56%, and 16%, respectively, of which the first 2 reached statistical significance. Median effective dose is reduced from 4.75\u00a0mSv in\n              <jats:styled-content style=\"fixed-case\">CCA<\/jats:styled-content>\n              to 2.22\u00a0mSv in\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              procedures, where the latter is further reduced to 1.79\u00a0mSv when excluding ventriculography.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec xml:lang=\"en\">\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p xml:lang=\"en\">\n              During invasive coronary angiography,\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              reduces radiation exposure even further toward low\u2010dose values on a system already equipped with advanced image processing and noise reduction algorithms. For both\n              <jats:styled-content style=\"fixed-case\">DARCA<\/jats:styled-content>\n              and\n              <jats:styled-content style=\"fixed-case\">CCA<\/jats:styled-content>\n              procedures, using 1 effective dose conversion factor of 0.30\u00a0mSv\u00b7Gy\n              <jats:sup>\u22121<\/jats:sup>\n              \u00b7cm\n              <jats:sup>\u22122<\/jats:sup>\n              is feasible.\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1161\/jaha.119.014683","type":"journal-article","created":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T09:02:07Z","timestamp":1593594127000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":9,"title":["Combining Optimized Image Processing With Dual Axis Rotational Angiography: Toward Low\u2010Dose Invasive Coronary Angiography"],"prefix":"10.1161","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0592-5873","authenticated-orcid":false,"given":"Dimitri","family":"Buytaert","sequence":"first","affiliation":[{"name":"Department of Human Structure and Repair Ghent University Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benny","family":"Drieghe","sequence":"additional","affiliation":[{"name":"Heart Center Ghent University Hospital Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fr\u00e9d\u00e9ric","family":"Van Heuverswyn","sequence":"additional","affiliation":[{"name":"Heart Center Ghent University Hospital Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"De Pooter","sequence":"additional","affiliation":[{"name":"Heart Center Ghent University Hospital Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Gheeraert","sequence":"additional","affiliation":[{"name":"Heart Center Ghent University Hospital Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dani\u00ebl","family":"De Wolf","sequence":"additional","affiliation":[{"name":"Department of Paediatric Cardiology Ghent University Hospital Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yves","family":"Taeymans","sequence":"additional","affiliation":[{"name":"Heart Center Ghent University Hospital Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Bacher","sequence":"additional","affiliation":[{"name":"Department of Human Structure and Repair Ghent University Ghent Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"e_1_3_1_2_2","unstructured":"Eurostat . Health in the European Union\u2014facts and figures. Available at: https:\/\/ec.europa.eu\/euros\u200btat\/stati\u200bstics-expla\u200bined\/index.php\/Health_in_the_Europ\u200bean_Union_%E2%80%93_facts_and_figures. Accessed May 17 2019."},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000659"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2458-10-537"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mrrev.2016.06.006"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.27173"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.92.8.2333"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.17.2345"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10554-016-0999-5"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ccl.2009.03.002"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2015.03.042"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22804"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.23415"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rec.2011.12.015"},{"key":"e_1_3_1_15_2","first-page":"1016","article-title":"Randomized study on the safety and efficacy of dual\u2010axis rotational versus standard coronary angiography in the Chinese population","volume":"125","author":"Liu HL","year":"2012","unstructured":"Liu HL, Jin ZG, Yang SL, Luo JP, Ma DX, Liu Y, Han W. Randomized study on the safety and efficacy of dual\u2010axis rotational versus standard coronary angiography in the Chinese population. Chin Med J (Engl). 2012;125:1016\u20131022.","journal-title":"Chin Med J (Engl)"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/joic.12054"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00380-013-0349-7"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/joic.12148"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2018.01.028"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v15i4.4805"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/joic.12553"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25913"},{"key":"e_1_3_1_23_2","doi-asserted-by":"crossref","first-page":"E419","DOI":"10.1002\/ccd.24879","article-title":"Three\u2010dimensional rotational X\u2010ray acquisition technique is reducing patients\u2019 cancer risk in coronary angiography","volume":"82","author":"Eloot L","year":"2013","unstructured":"Eloot L, Bacher K, Steenbeke F, Drieghe B, Gheeraert P, Taeymans Y, Thierens H. Three\u2010dimensional rotational X\u2010ray acquisition technique is reducing patients\u2019 cancer risk in coronary angiography. Catheter Cardiovasc Interv. 2013;82:E419\u2013E427.","journal-title":"Catheter Cardiovasc Interv"},{"key":"e_1_3_1_24_2","unstructured":"Cranley K Gilmore BJ Fogarty GWA Desponds L. Catalogue of diagnostic x\u2010ray spectra and other data (IPEM Report 78) . (Electronic version prepared by Sutton D). The Institution of Physics and Engineering in Medicine and Biology. 1997."},{"key":"e_1_3_1_25_2","unstructured":"European Commission Technical recommendations for monitoring individuals occupationally exposed to external radiation. European Commission Radiation Protection 160. (EC: Luxembourg) 2009."},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2011.05.073"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2017.03.018"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncn039"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2018.09.012"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jjcc.2015.08.012"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i3.5926"},{"key":"e_1_3_1_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2017.09.131"},{"key":"e_1_3_1_33_2","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/3\/001"},{"key":"e_1_3_1_34_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehm508"},{"key":"e_1_3_1_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2012.06.011"},{"key":"e_1_3_1_36_2","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/nch394"}],"container-title":["Journal of the American Heart Association"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/JAHA.119.014683","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T11:37:23Z","timestamp":1715600243000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/JAHA.119.014683"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,7]]},"references-count":35,"journal-issue":{"issue":"13","published-print":{"date-parts":[[2020,7,7]]}},"alternative-id":["10.1161\/JAHA.119.014683"],"URL":"https:\/\/doi.org\/10.1161\/jaha.119.014683","relation":{},"ISSN":["2047-9980"],"issn-type":[{"value":"2047-9980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,7]]},"assertion":[{"value":"2019-10-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-04-24","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e014683"}}