{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T16:20:48Z","timestamp":1795018848813,"version":"4.10.1"},"reference-count":0,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl_1","content-domain":{"domain":["www.ahajournals.org"],"crossmark-restriction":true},"short-container-title":["SVIN"],"published-print":{"date-parts":[[2026,10,18]]},"abstract":"<jats:p>\n                    <jats:bold>Introduction\/Purpose:<\/jats:bold>\n                    Balloon guide catheters (BGCs), while traditionally developed for arterial thrombectomy, offer proximal support and distal flexibility that may enable stable anchoring and navigation through tortuous jugular bulb and sigmoid sinus anatomy. We present the first largest clinical experience describing the off-label utility of BGCs in venous sinus stenting (VSS).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Materials\/Methods:<\/jats:bold>\n                    We retrospectively reviewed 69 patients undergoing BGC-assisted VSS (September 2022-February 2026). BGC use was characterized as anchoring, stent delivery, and\/or post-stenting balloon angioplasty. Other procedural variables including BGC tip location and stenting details, along with navigation attempts and complications were recorded. A secondary analysis comparing Dr. Banner and Walrus BGC was conducted.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:<\/jats:bold>\n                    Among 69 procedures, the Dr. Banner (82.6%) and Walrus (14.5%) BGCs were most commonly used. The Dr. Banner tip was most frequently positioned in the sigmoid sinus (38.9%), while the Walrus most commonly seated at the TS junction (50.0%; p=0.025). Stents were deployed most commonly at the TS junction with Dr. Banner (63.0%), and equally at the sigmoid sinus and TS junction with the Walrus BGC (40.0% each; p=0.004). The largest stents delivered were 10 mm via Dr. Banner and 12 mm via Walrus. BGCs were used for anchoring in 95.7% and stent delivery in 52.2% of procedures. A single navigation attempt sufficed in 94.2% of cases; crossover was required in 3 (4.3%) Dr. Banner cases due to TS junction angle or severe stenosis hindering BGC navigation. Walrus BGC cases required a higher radiation dose (1400 vs. 1103 mGy, p=0.028) and contrast volume (150 vs. 100 ml, p=0.001). The overall complication rate was 7.2%.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusion:<\/jats:bold>\n                    BGCs demonstrate high technical utility for anchoring while ensuring delivery of large stents in VSS. Dr. Banner BGC enables more distal tracking while Walrus BGC permits stent delivery from a more proximal position at the expense of higher cumulative radiation exposure and contrast volume utilization.\n                  <\/jats:p>","DOI":"10.1161\/svi270000_1258","type":"journal-article","created":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T15:41:15Z","timestamp":1795016475000},"update-policy":"https:\/\/doi.org\/10.1161\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":0,"title":["Abstract 1258: Balloon Guide Catheters In Venous Sinus Stenting: The First Largest Clinical Experience In 69 Patients"],"prefix":"10.1161","volume":"6","author":[{"given":"W.","family":"Ahmed","sequence":"first","affiliation":[{"name":"Aga Khan University, Karachi, PAKISTAN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Gaston","sequence":"additional","affiliation":[{"name":"Neurosurgery, Hospital of the University of Pennsylvania, Philadelphia, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Kim","sequence":"additional","affiliation":[{"name":"Neurosurgery, Hospital of the University of Pennsylvania, Philadelphia, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Durrani","sequence":"additional","affiliation":[{"name":"Aga Khan University, Karachi, PAKISTAN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Gandhi","sequence":"additional","affiliation":[{"name":"Neurosurgery, Hospital of the University of Pennsylvania, Philadelphia, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Bagley","sequence":"additional","affiliation":[{"name":"Neurosurgery, Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Choudhri","sequence":"additional","affiliation":[{"name":"Radiology, Hospital of the University of Pennsylvania, Karachi, PA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","container-title":["Stroke: Vascular and Interventional Neurology"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T15:43:01Z","timestamp":1795016581000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ahajournals.org\/doi\/10.1161\/svi270000_1258"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,18]]},"references-count":0,"journal-issue":{"issue":"Suppl_1","published-print":{"date-parts":[[2026,10,18]]}},"alternative-id":["10.1161\/svi270000_1258"],"URL":"https:\/\/doi.org\/10.1161\/svi270000_1258","relation":{},"ISSN":["2694-5746"],"issn-type":[{"value":"2694-5746","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,18]]},"assertion":[{"value":"2026-11-18","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}