{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T18:18:33Z","timestamp":1790360313121,"version":"4.1.0"},"reference-count":113,"publisher":"Croatian Society for Medical Biochemistry and Laboratory Medicine","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biochem. med. (Online)"],"published-print":{"date-parts":[[2020,2,15]]},"abstract":"<jats:p>Extravascular body fluids (EBF) analysis can provide useful information in the differential diagnosis of conditions that caused their accumulation. Their unique nature and particular requirements accompanying EBF analysis need to be recognized in order to minimize possible negative implications on patient safety. This recommendation was prepared by the members of the Working group for extravascular body fluid samples (WG EBFS). It is designed to address the total testing process and clinical significance of tests used in EBF analysis. The recommendation begins with a chapter addressing validation of methods used in EBF analysis, and continues with specific recommendations for serous fluids analysis. It is organized in sections referring to the preanalytical, analytical and postanalytical phase with specific recommendations presented in boxes. Its main goal is to assist in the attainment of national harmonization of serous fluid analysis and ultimately improve patient safety and healthcare outcomes. This recommendation is intended to all laboratory professionals performing EBF analysis and healthcare professionals involved in EBF collection and processing. Cytological and microbiological evaluations of EBF are beyond the scope of this document.<\/jats:p>","DOI":"10.11613\/bm.2020.010502","type":"journal-article","created":{"date-parts":[[2019,12,13]],"date-time":"2019-12-13T12:21:26Z","timestamp":1576239686000},"page":"31-59","source":"Crossref","is-referenced-by-count":21,"title":["Laboratory testing of extravascular body fluids"],"prefix":"10.11613","volume":"30","author":[{"given":"Lara","family":"Milevoj Kopcinovic","sequence":"first","affiliation":[{"name":"Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples; Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jelena","family":"Culej","sequence":"additional","affiliation":[{"name":"Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples; Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anja","family":"Jokic","sequence":"additional","affiliation":[{"name":"Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples; Department of Medical Biochemistry, Haematology and Coagulation with Cytology, University Hospital for Infectious Diseases \u201cDr. Fran Miha"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marija","family":"Bozovic","sequence":"additional","affiliation":[{"name":"Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples; Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Irena","family":"Kocijan","sequence":"additional","affiliation":[{"name":"Croatian Society of Medical Biochemistry and Laboratory Medicine, Working group for extravascular body fluid samples; Medical Biochemistry Laboratory, General hospital Vara\u017edin, Vara\u017edin, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4885","published-online":{"date-parts":[[2020,2,15]]},"reference":[{"key":"key20191213122123_r1","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1309\/3REBHJFAQVLXUQ5W","article-title":"To test or not to test? Opening Pandora\u2019s box.","volume":"35","author":"Wians","year":"2004","journal-title":"Lab Med"},{"key":"key20191213122123_r2","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.clinbiochem.2018.05.002","article-title":"An approach to analytical validation and testing of body fluid assays for the automated clinical laboratory.","volume":"58","author":"Block","year":"2018","journal-title":"Clin Biochem"},{"key":"key20191213122123_r3","unstructured":"Akgul M, Noguez J. Body fluid testing: what you should know before you hit go. Available at: https:\/\/www.aacc.org\/publications\/cln\/articles\/2015\/october\/body-fluid-testing-what-you- should-know-before-you-hit-go. Accessed November 4th 2015."},{"key":"key20191213122123_r4","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1515\/cclm-2016-0862","article-title":"Opportunities and drawbacks of nonstandard body fluid analysis.","volume":"55","author":"Lippi","year":"2017","journal-title":"Clin Chem Lab Med"},{"key":"key20191213122123_r5"},{"key":"key20191213122123_r6"},{"key":"key20191213122123_r7","doi-asserted-by":"crossref","first-page":"242","DOI":"10.11613\/BM.2013.031","article-title":"Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling.","volume":"23","author":"Nikolac","year":"2013","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r8","doi-asserted-by":"crossref","first-page":"335","DOI":"10.11613\/BM.2015.034","article-title":"Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.","volume":"25","author":"Lenicek Krleza","year":"2015","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r9","doi-asserted-by":"crossref","first-page":"318","DOI":"10.11613\/BM.2016.036","article-title":"Blood gas testing and related measurements: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.","volume":"26","author":"Duki\u0107","year":"2016","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r10","doi-asserted-by":"crossref","first-page":"153","DOI":"10.11613\/BM.2017.019","article-title":"The role of laboratory testing in detection and classification of chronic kidney disease: National recommendations.","volume":"27","author":"Biljak","year":"2017","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r11","doi-asserted-by":"crossref","DOI":"10.11613\/BM.2017.030502","article-title":"Minimum requirements for the estimation of measurement uncertainty: Recommendations of the joint Working group for uncertainty of measurement of the CSMBLM and CCMB.","volume":"27","author":"\u0106elap","year":"2017","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r12","doi-asserted-by":"crossref","first-page":"395","DOI":"10.11613\/BM.2016.042","article-title":"Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine.","volume":"26","author":"Kopcinovic","year":"2016","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r13"},{"key":"key20191213122123_r14","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1258\/0004563011900812","article-title":"Biochemical analysis of pleural fluid: what should we measure?","volume":"38","author":"Tarn","year":"2001","journal-title":"Ann Clin Biochem"},{"key":"key20191213122123_r15","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.cll.2014.10.003","article-title":"Body fluid cell counts by automated methods.","volume":"35","author":"Sandhaus","year":"2015","journal-title":"Clin Lab Med"},{"key":"key20191213122123_r16"},{"key":"key20191213122123_r17","unstructured":"College of American Pathologists (CAP) Accreditation Program. All common checklist. Available at: http:\/\/www.cap.org\/ShowProperty?nodePath=\/UCMCon\/Contribution%20Folders\/DctmContent\/education\/OnlineCourseContent\/2016\/LAP-TLTM\/resources\/AC-all-common.pdf. Accessed February 12th 2018."},{"key":"key20191213122123_r18","doi-asserted-by":"crossref","first-page":"107","DOI":"10.3109\/10408363.2013.844679","article-title":"Body fluid analysis: clinical utility and applicability of published studies to guide interpretation of today\u2019s laboratory testing in serous fluids.","volume":"50","author":"Block","year":"2013","journal-title":"Crit Rev Clin Lab Sci"},{"key":"key20191213122123_r19","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.plabm.2016.03.003","article-title":"Filling in the gaps with non-standard body fluids.","volume":"5","author":"Lo","year":"2016","journal-title":"Pract Lab Med."},{"key":"key20191213122123_r20","unstructured":"Cotten SW. Validating the performance of body fluid specimens. Available at: https:\/\/www.medlabmag.com\/article\/1291. Accessed July 1st 2016."},{"key":"key20191213122123_r21"},{"key":"key20191213122123_r22","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1111\/ijlh.12196","article-title":"International Committee for Standardization in Hematology (ICSH). ICSH guidelines for the verification and performance of automated cell counters for body fluids.","volume":"36","author":"Bourner","year":"2014","journal-title":"Int J Lab Hematol"},{"key":"key20191213122123_r23","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.cccn.2004.02.002","article-title":"Biochemical analysis of pleural, pericardial and peritoneal effusions.","volume":"343","author":"Burgess","year":"2004","journal-title":"Clin Chim Acta"},{"key":"key20191213122123_r24","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/MAJ.0b013e31815d25e6","article-title":"The value of pleural fluid analysis.","volume":"335","author":"Sahn","year":"2008","journal-title":"Am J Med Sci"},{"key":"key20191213122123_r25","unstructured":"Croatian Society for Medical Biochemistry. Sadr\u017eaj laboratorijskog nalaza. Available at: http:\/\/www.hkmb.hr\/preporuke\/aktualno\/sadrzaj-laboratorijskog-nalaza.htm.(In Croatian). Accessed March 25th, 2016."},{"key":"key20191213122123_r26","unstructured":"Calgary Laboratory Services. Body fluid collection guidelines. Available at: http:\/\/www.calgarylabservices.com\/edu-cation-research\/medical-professionals-ducation. Accessed November 4th 2015."},{"key":"key20191213122123_r27","doi-asserted-by":"crossref","first-page":"123","DOI":"10.11613\/BM.2014.014","article-title":"Pleural, peritoneal and pericardial effusions \u2013 a biochemical approach.","volume":"24","author":"Kopcinovic","year":"2014","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r28","unstructured":"Altoona Regional Laboratory Services. Specimen collection, preparation and handling: body fluids. Available at: http:\/\/www.altoonaregional.org\/lab\/pdfs\/8_SC_Body_fluids.pdf. Accessed November 4th 2015."},{"key":"key20191213122123_r29","unstructured":"Alberta Health Laboratory Services. Specimen collection and handling of fluids(excluding CSF). Available at: http:\/\/www.albertahealthservices.ca\/assets\/wf\/lab\/wf-lab-collection-of-fluids-except-csf.pdf. Accessed Accessed November 4th 2015"},{"key":"key20191213122123_r30","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1258\/000456307781645978","article-title":"Biochemical analysis of pleural and ascetic fluid: effect of sample timing on interpretation of results.","volume":"44","author":"Jenkinson","year":"2007","journal-title":"Ann Clin Biochem"},{"key":"key20191213122123_r31","unstructured":"Lechtzin N. Thoracentesis. Available at: http:\/\/www.merckmanuals.com\/professional\/pulmonary-disorders\/diagnostic-pulmonary-procedures\/thoracentesis. Accessed November 4th 2015."},{"key":"key20191213122123_r32","unstructured":"Higgins C. Clinical aspects of pleural fluid pH. Available at: https:\/\/acutecaretesting.org\/en\/articles\/clinical-aspects-of-pleural-fluid-ph. Accessed February 23rd 2019."},{"key":"key20191213122123_r33","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1378\/chest.114.5.1368","article-title":"Comparison of pleural fluid pH values obtained using blood gas machine, pH meter, and pH indicator strip.","volume":"114","author":"Cheng","year":"1998","journal-title":"Chest"},{"key":"key20191213122123_r34","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1016\/j.mcna.2011.08.005","article-title":"Pleural effusions.","volume":"95","author":"Light","year":"2011","journal-title":"Med Clin North Am"},{"key":"key20191213122123_r35","doi-asserted-by":"crossref","first-page":"507","DOI":"10.7326\/0003-4819-77-4-507","article-title":"Pleural effusions: the diagnostic separation of transudates and exudates.","volume":"77","author":"Light","year":"1972","journal-title":"Ann Intern Med"},{"key":"key20191213122123_r36","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.ccm.2012.11.006","article-title":"The Light criteria: the beginning and why they are useful 40 years later.","volume":"34","author":"Light","year":"2013","journal-title":"Clin Chest Med"},{"key":"key20191213122123_r37","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1378\/chest.111.4.970","article-title":"Diagnostic value of test that discriminate between exudative and transudative pleural effusions.","volume":"111","author":"Heffner","year":"1997","journal-title":"Chest"},{"key":"key20191213122123_r38","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1111\/j.1440-1843.2010.01794.x","article-title":"Pearls and myths in pleural fluid analysis.","volume":"16","author":"Porcel","year":"2011","journal-title":"Respirology"},{"key":"key20191213122123_r39","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1097\/MCP.0b013e32836022dc","article-title":"Identifying transudates misclassified by Light\u2019s criteria.","volume":"19","author":"Porcel","year":"2013","journal-title":"Curr Opin Pulm Med"},{"key":"key20191213122123_r40","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1378\/chest.98.3.546","article-title":"The serum-effusion albumin gradient in the evaluation of pleural effusions.","volume":"98","author":"Roth","year":"1990","journal-title":"Chest"},{"key":"key20191213122123_r41","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/j.1440-1843.2012.02155.x","article-title":"Solving the Light\u2019s criteria misclassification rate of cardiac and hepatic transudates.","volume":"17","author":"Bielsa","year":"2012","journal-title":"Respirology"},{"key":"key20191213122123_r42","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1378\/chest.108.5.1260","article-title":"Measurement of pleural fluid cholesterol and lactate dehydrogenase. A simple and accurate set of indicators for separating exudates from transudates.","volume":"108","author":"Costa","year":"1995","journal-title":"Chest"},{"key":"key20191213122123_r43","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1378\/chest.09-0270","article-title":"Biomarkers of heart failure in pleural fluid.","volume":"136","author":"Porcel","year":"2009","journal-title":"Chest"},{"key":"key20191213122123_r44","article-title":"Diagnostic accuracy of natriuretic peptides for heart failure in patients with pleural effusion: a systematic review and updated meta-analysis.","volume":"10","author":"Han","year":"2015","journal-title":"PLoS One"},{"key":"key20191213122123_r45","article-title":"Pleural fluid analysis: standstill or a work in progress?","volume":"716235","author":"Hasan","year":"2012","journal-title":"Pulm Med Hindawi."},{"key":"key20191213122123_r46","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/MCP.0b013e3283455cda","article-title":"Utilization of B-type natriuretic peptide and NT-proBNP in the diagnosis of pleural effusions due to heart failure.","volume":"17","author":"Porcel","year":"2011","journal-title":"Curr Opin Pulm Med"},{"key":"key20191213122123_r47","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1111\/j.1440-1843.2011.02100.x","article-title":"Getting the most from pleural fluid analysis.","volume":"17","author":"Sahn","year":"2012","journal-title":"Respirology"},{"key":"key20191213122123_r48","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1515\/cclm-2014-1247","article-title":"Clinical relevance and contemporary methods for counting blood cells in body fluids suspected of inflammatory disease.","volume":"53","author":"Fleming","year":"2015","journal-title":"Clin Chem Lab Med"},{"key":"key20191213122123_r49","unstructured":"Huggins JT. Pleural fluid eosinophilia. Available at: https:\/\/www.uptodate.com\/contents\/pleural-fluid-eosinophilia. Accessed Accessed January 15th 2018."},{"key":"key20191213122123_r50","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1001\/archinte.161.2.228","article-title":"Routine measurement of pleural fluid amylase is not indicated.","volume":"161","author":"Branca","year":"2001","journal-title":"Arch Intern Med"},{"key":"key20191213122123_r51","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.rmed.2010.03.008","article-title":"The use of non-routine pleural fluid analysis in the diagnosis of pleural effusion.","volume":"104","author":"McGrath","year":"2010","journal-title":"Respir Med"},{"key":"key20191213122123_r52","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1378\/chest.121.2.470","article-title":"Amylase levels in pleural effusions: a consecutive unselected series of 841 patients.","volume":"121","author":"Villena","year":"2002","journal-title":"Chest"},{"key":"key20191213122123_r53","first-page":"3126","article-title":"Diagnosis of tuberculosis pleurisy with adenosine deaminase (ADA): a systematic review and meta analysis.","volume":"7","author":"Gui","year":"2014","journal-title":"Int J Clin Exp Med"},{"key":"key20191213122123_r54","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.rmed.2007.12.007","article-title":"Diagnostic accuracy of adenosine deaminase in tuberculous pleurisy: a meta analysis.","volume":"102","author":"Liang","year":"2008","journal-title":"Respir Med"},{"key":"key20191213122123_r55","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/MCP.0b013e32833a7154","article-title":"Use of pleural fluid levels of adenosine deaminase and interferon gamma in the diagnosis of tuberculous pleuritits.","volume":"16","author":"Krenke","year":"2010","journal-title":"Curr Opin Pulm Med"},{"key":"key20191213122123_r56","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1097\/MCP.0b013e328338dde2","article-title":"Chylothorax: diagnostic approach.","volume":"16","author":"Skouras","year":"2010","journal-title":"Curr Opin Pulm Med"},{"key":"key20191213122123_r57","unstructured":"Heffner JE. Clinical presentation and management of cholesterol effusions. Available at: https:\/\/www.uptodate.com\/contents\/clinical-presentation-diagnosis-and-management-of-cholesterol-effusions. Accessed January 15th 2018."},{"key":"key20191213122123_r58","unstructured":"Heffner JE. Etiology, clinical presentation, and diagnosis of chylothorax. Available at: https:\/\/www.uptodate.com\/contents\/etiology-clinical-presentation-and-diagnosis-of-chylothorax. Accessed January 15th 2018."},{"key":"key20191213122123_r59","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/01.mcp.0000230628.65515.86","article-title":"Urinothorax: a new approach.","volume":"12","author":"Garcia-Pachon","year":"2006","journal-title":"Curr Opin Pulm Med"},{"key":"key20191213122123_r60","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.ccm.2005.12.002","article-title":"The undiagnosed pleural effusion.","volume":"27","author":"Light","year":"2006","journal-title":"Clin Chest Med."},{"key":"key20191213122123_r61","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.21037\/jtd.2017.04.22","article-title":"Urinothorax: a systematic review.","volume":"9","author":"Toubes","year":"2017","journal-title":"J Thorac Dis"},{"key":"key20191213122123_r62","doi-asserted-by":"crossref","first-page":"e336","DOI":"10.3747\/co.22.2563","article-title":"Pleural fluid tumour markers in malignant pleural effusion with inconclusive cytologic results.","volume":"22","author":"Antonangelo","year":"2015","journal-title":"Curr Oncol"},{"key":"key20191213122123_r63","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1016\/j.clinbiochem.2016.08.006","article-title":"Evaluation of predictive value of pleural CEA in patients with pleural effusions and histological findings; A prospective study and literature review.","volume":"49","author":"Tozzoli","year":"2016","journal-title":"Clin Biochem"},{"key":"key20191213122123_r64","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.cca.2010.05.015","article-title":"Pleural fluid: are temperature and storage time critical preanalytical errors factors in biochemical analyses?","volume":"411","author":"Antonangelo","year":"2010","journal-title":"Clin Chim Acta"},{"key":"key20191213122123_r65","unstructured":"Kilpatrick E. Best Practice when providing interpretative comments on laboratory medicine reports. Available at: http:\/\/acb.org.uk\/docs\/default-source\/committees\/scientific\/guidelines\/acb\/best-practice-when-providing-interpretative-comments-for-laboratory-medicine---final.pdf?sfvrsn=2. Accessed November 4th 2015."},{"key":"key20191213122123_r66","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.cca.2009.03.012","article-title":"Interpretative commenting: a tool for improving the laboratory\u2013clinical interface.","volume":"404","author":"Plebani","year":"2009","journal-title":"Clin Chim Acta"},{"key":"key20191213122123_r67","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1111\/j.1365-2303.2011.00863.x","article-title":"Effect of temperature and storage time on cellular analysis of fresh pleural fluid samples.","volume":"23","author":"Antonangelo","year":"2012","journal-title":"Cytopathology"},{"key":"key20191213122123_r68","unstructured":"Hoit BD. Diagnosis and treatment of pericardial effusion. Available at: https:\/\/www.uptodate.com\/contents\/diagnosis-and-treatment-of-pericardial-effusion. Accessed January 15th 2018."},{"key":"key20191213122123_r69","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.amjmed.2005.01.066","article-title":"The composition of normal pericardial fluid and its implications for diagnosing pericardial effusions.","volume":"118","author":"Ben-Horin","year":"2005","journal-title":"Am J Med"},{"key":"key20191213122123_r70","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1378\/chest.111.5.1213","article-title":"The usefulness of diagnostic tests on pericardial fluid.","volume":"111","author":"Meyers","year":"1997","journal-title":"Chest"},{"key":"key20191213122123_r71","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1378\/chest.121.2.495","article-title":"Role of biochemical tests in the diagnosis of large pericardial effusions.","volume":"121","author":"Burgess","year":"2002","journal-title":"Chest"},{"key":"key20191213122123_r72","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1016\/j.amjcard.2006.12.048","article-title":"Diagnostic value of the biochemical composition of pericardial effusions in patients undergoing pericardiocentesis.","volume":"99","author":"Ben-Horin","year":"2007","journal-title":"Am J Cardiol"},{"key":"key20191213122123_r73","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1093\/qjmed\/hcl123","article-title":"Diagnosing tuberculous pericarditis.","volume":"99","author":"Reuter","year":"2006","journal-title":"QJM"},{"key":"key20191213122123_r74"},{"key":"key20191213122123_r75","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1258\/acb.2010.010048","article-title":"Biochemical analysis of ascitic (peritoneal) fluid: what should we measure?","volume":"47","author":"Tarn","year":"2010","journal-title":"Ann Clin Biochem"},{"key":"key20191213122123_r76","unstructured":"Balfe A, Barry S, Blake O, Cannon D, Healy M, Kilbane M, et al. The biochemistry of body fluids. Available at: http:\/\/www.biochemiran.com\/files\/site1\/pages\/guidelines-of-body-fluids.pdf. Accessed November 4th 2015."},{"key":"key20191213122123_r77","first-page":"58","article-title":"Ascitic fluid analysis in the differential diagnosis of ascites: focus on cirrhotic ascites.","volume":"2","author":"Huang","year":"2014","journal-title":"J Clin Transl Hepatol"},{"key":"key20191213122123_r78","doi-asserted-by":"crossref","first-page":"vi1","DOI":"10.1136\/gut.2006.099580","article-title":"Guidelines on the management of ascites in cirrhosis.","volume":"55","author":"Moore","year":"2006","journal-title":"Gut"},{"key":"key20191213122123_r79","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.jhep.2010.05.004","article-title":"European Association for the Study of the Liver (EASL). EASL clinical practice guidelines on the management of ascites, spontaneous bacterial peritonitis, and hepatorenal syndrome in cirrhosis.","volume":"53","author":"Gines","year":"2010","journal-title":"J Hepatol"},{"key":"key20191213122123_r80","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1002\/hep.26359","article-title":"AASLD Practice guidelines committee. Management of adult patients with ascites due to cirrhosis: Update 2012.","volume":"57","author":"Runyon","year":"2013","journal-title":"Hepatology"},{"issue":"1","key":"key20191213122123_r81","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0168-8278(00)80201-9","article-title":"Diagnosis, treatment and prophylaxis of spontaneous bacterial peritonitis: a consensus document. International Ascites Club.","volume":"32","author":"Rimola","year":"2000","journal-title":"J Hepatol"},{"key":"key20191213122123_r82","first-page":"80","article-title":"Ascites: Diagnosis and management.","volume":"5","author":"Sood","year":"2000","journal-title":"J Indian Acad Clin Med."},{"key":"key20191213122123_r83","first-page":"748","article-title":"Serum ascites gradient in differential diagnosis of ascites.","volume":"22","author":"Uddin","year":"2013","journal-title":"Mymensingh Med J"},{"key":"key20191213122123_r84","doi-asserted-by":"crossref","first-page":"215","DOI":"10.7326\/0003-4819-117-3-215","article-title":"The serum ascites albumin gradient is superior to the exudate-transudate concept in the differential diagnosis of ascites.","volume":"117","author":"Runyon","year":"1992","journal-title":"Ann Intern Med"},{"key":"key20191213122123_r85","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1136\/jcp.55.1.69","article-title":"New criteria for the differentiation between transudates and exudates.","volume":"55","author":"Paramothayan","year":"2002","journal-title":"J Clin Pathol"},{"key":"key20191213122123_r86","first-page":"97","article-title":"Role of serum \u2013 ascites albumin gradient in differental diagnosis of ascites.","volume":"24","author":"Younas","year":"2012","journal-title":"J Ayub Med Coll Abbottabad"},{"key":"key20191213122123_r87","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1002\/hep.1840160218","article-title":"Globulin correction of the albumin gradient: correlation with measured serum to ascites colloid osmotic pressure gradients.","volume":"16","author":"Hoefs","year":"1992","journal-title":"Hepatology"},{"key":"key20191213122123_r88","doi-asserted-by":"crossref","first-page":"152","DOI":"10.11613\/BM.2011.024","article-title":"New ways to deal with known preanalytical issues: use of transluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry.","volume":"21","author":"Lima-Oliveira","year":"2011","journal-title":"Biochem Med (Zagreb)"},{"key":"key20191213122123_r89","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1136\/pgmj.2006.056168","article-title":"Spontaneous bacterial peritonitis.","volume":"83","author":"Koulaouzidis","year":"2007","journal-title":"Postgrad Med J"},{"key":"key20191213122123_r90","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1111\/j.1478-3231.2005.01176.x","article-title":"Usefulness of urine strip test in the rapid diagnosis of spontaneous bacterial peritonitis.","volume":"25","author":"Kim","year":"2005","journal-title":"Liver Int"},{"key":"key20191213122123_r91","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1590\/S1516-31802006000300006","article-title":"Araujo Filho AH Diagnosis of spontaneous bacterial peritonitis in northeastern Brazil by use of rapid urine-screening test.","volume":"124","author":"Braga","year":"2006","journal-title":"Sao Paulo Med J"},{"key":"key20191213122123_r92","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1097\/MEG.0b013e328300a363","article-title":"Leucocyte esterase reagent strips for the diagnosis of spontaneous bacterial peritonitis: a systematic review.","volume":"20","author":"Koulaouzidis","year":"2008","journal-title":"Eur J Gastroenterol Hepatol"},{"key":"key20191213122123_r93","doi-asserted-by":"crossref","first-page":"3845","DOI":"10.3748\/wjg.15.3845","article-title":"Ascitic fluid analysis for diagnosis and monitoring of spontaneous bacterial peritonitis.","volume":"15","author":"Riggio","year":"2009","journal-title":"World J Gastroenterol"},{"key":"key20191213122123_r94","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1111\/j.1365-2036.2008.03735.x","article-title":"Review article: the utility of reagent strips in the diagnosis of infected ascites in cirrhotic patients.","volume":"28","author":"Nguyen-Khac","year":"2008","journal-title":"Aliment Pharmacol Ther"},{"key":"key20191213122123_r95","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1002\/hep.21588","article-title":"Diagnostic accuracy of the Multistix 8 SG reagent strip in diagnosis of spontaneous bacterial peritonitis.","volume":"45","author":"Nousbaum","year":"2007","journal-title":"Hepatology"},{"key":"key20191213122123_r96","unstructured":"Runyon BA. Spontaneous bacterial peritonitis in adults: diagnosis. Available at: https:\/\/www.uptodate.com\/contents\/spontaneous-bacterial-peritonitis-in-adults-diagnosis. Accessed January 15th 2018."},{"key":"key20191213122123_r97","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1002\/jcla.21994","article-title":"Ascitic calprotectin is a novel and accurate marker for spontaneous bacterial peritonitis.","volume":"30","author":"Fernandes","year":"2016","journal-title":"J Clin Lab Anal"},{"key":"key20191213122123_r98","doi-asserted-by":"crossref","first-page":"624","DOI":"10.5009\/gnl15120","article-title":"Ascitic fluid calprotectin and serum procalcitonin as accurate diagnostic markers for spontaneous bacterial peritonitis.","volume":"10","author":"Abdel-Razik","year":"2016","journal-title":"Gut Liver"},{"key":"key20191213122123_r99","doi-asserted-by":"crossref","first-page":"2618","DOI":"10.20546\/ijcmas.2018.702.319","article-title":"Diagnostic value of ascitic fluid lactoferrin, calprotectin, and calprotectin to albumin ratio in spontaneous bacterial peritonitis.","volume":"7","author":"Makhlouf","year":"2018","journal-title":"Int J Curr Microbiol Appl Sci"},{"key":"key20191213122123_r100","unstructured":"Cardenas A, Gelrud A, Chopra S. Chylous, bloody and pancreatic ascites. Available at: https:\/\/www.uptodate.com\/contents\/chylous-bloody-and-pancreatic-ascites. Accessed January 15th 2018."},{"key":"key20191213122123_r101","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/240473","article-title":"Chylous ascites: Evaluation and management.","volume":"2014","author":"Al-Busafi","year":"2014","journal-title":"ISRN Hepatol"},{"key":"key20191213122123_r102","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.jamcollsurg.2008.07.007","article-title":"Chylous ascites after pancreaticoduodenectomy: introduction of a grading system.","volume":"207","author":"van der Gaag","year":"2008","journal-title":"J Am Coll Surg"},{"key":"key20191213122123_r103","unstructured":"Runyon BA. Evaluation of adults with ascites. Available at: https:\/\/www.uptodate.com\/contents\/evaluation-of-adults-with-ascites. Accessed January 15th 2018."},{"key":"key20191213122123_r104","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1097\/00004836-200609000-00009","article-title":"Value of adenosine deaminase (ADA) in ascitic fluid for the diagnosis of tuberculous peritonitis. A meta-analysis.","volume":"40","author":"Riquelme","year":"2006","journal-title":"J Clin Gastroenterol"},{"key":"key20191213122123_r105","first-page":"2133","article-title":"New tools for the diagnosis of peritoneal carcinomatosis?","volume":"97","author":"Koch","year":"2002","journal-title":"Am J Gastroenterol"},{"key":"key20191213122123_r106","first-page":"CR136","article-title":"Usefulness of ascitic fluid cholesterol as a marker for malignant ascites.","volume":"11","author":"Rana","year":"2005","journal-title":"Med Sci Monit"},{"key":"key20191213122123_r107","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1515\/cclm-2011-0927","article-title":"Validation of the body fluid module on the new Sysmex XN-1000 for counting blood cells in cerebrospinal fluid and other body fluids.","volume":"50","author":"Fleming","year":"2012","journal-title":"Clin Chem Lab Med"},{"key":"key20191213122123_r108","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1093\/ajcp\/aqv093","article-title":"Evaluation of Sysmex XN-1000 High-Sensitive Analysis (hsA) Research Mode for Counting and Differentiating Cells in Cerebrospinal Fluid.","volume":"145","author":"Fleming","year":"2016","journal-title":"Am J Clin Pathol"},{"key":"key20191213122123_r109","first-page":"150","article-title":"Evaluation of pleural and ascitic fluid analysis on the Sysmex XE-5000 hematology analyser.","volume":"53","author":"Cognialli","year":"2017","journal-title":"J Bras Patol Med Lab"},{"key":"key20191213122123_r110","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/ijlh.12728","article-title":"Automated cell counts on CSF samples: A multicentre performance evaluation of the GloCyte system.","volume":"40","author":"Hod","year":"2018","journal-title":"Int J Lab Hematol"},{"key":"key20191213122123_r111","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1177\/2211068215593375","article-title":"Reflex testing rules for cell count and differentiation of nucleated elements in pleural and ascitic fluid on Sysmex XE-5000.","volume":"21","author":"Buoro","year":"2016","journal-title":"J Lab Autom"},{"key":"key20191213122123_r112","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.cca.2015.11.005","article-title":"Cell population data and reflex testing rules of cell analysis in pleural and ascitic fluids using body fluid mode on Sysmex XN-9000.","volume":"452","author":"Buoro","year":"2016","journal-title":"Clin Chim Acta"},{"key":"key20191213122123_r113","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.cca.2016.08.018","article-title":"Optimization of Cellular analysis of Synovial Fluids by optical microscopy and automated count using the Sysmex XN Body Fluid Mode.","volume":"462","author":"Seghezzi","year":"2016","journal-title":"Clin Chim Acta"}],"container-title":["Biochemia medica"],"original-title":[],"link":[{"URL":"https:\/\/www.biochemia-medica.com\/assets\/images\/upload\/xml_tif\/bm-30-1-010502.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,17]],"date-time":"2020-02-17T08:20:56Z","timestamp":1581927656000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.biochemia-medica.com\/en\/journal\/30\/1\/10.11613\/BM.2020.010502"}},"subtitle":["National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Part I \u2013 Serous fluids"],"short-title":[],"issued":{"date-parts":[[2020,2,15]]},"references-count":113,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,2,15]]},"published-print":{"date-parts":[[2020,2,15]]}},"URL":"https:\/\/doi.org\/10.11613\/bm.2020.010502","relation":{},"ISSN":["1846-7482","1330-0962"],"issn-type":[{"value":"1846-7482","type":"electronic"},{"value":"1330-0962","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2,15]]}}}