{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T17:03:46Z","timestamp":1778346226738,"version":"3.51.4"},"reference-count":28,"publisher":"Croatian Society for Medical Biochemistry and Laboratory Medicine","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biochem. med. (Online)"],"published-print":{"date-parts":[[2020,10,15]]},"abstract":"<jats:p>Introduction: Hyperkalaemia is a common electrolyte disorder that may cause life-threatening cardiac arrythmias. We aimed to determine the\nagreement of potassium concentrations between GEM premier 3500 point-of-care blood gas analyser (POC-BGA) and Roche Cobas 6000 c501 autoanalyser\nin patients with hyperkalaemia.\nMethods: A prospective, cross-sectional study of all consecutive adult patients referred to the Renal Unit with a serum potassium concentration \u2265\n5.5 mmol\/L was performed. A total of 59 paired venous blood samples were included in the final statistical analysis. Passing-Bablok regression and\nBland Altman analysis were used to compare the two methods.\nResults: The median laboratory auto-analyser potassium concentration was 6.1 (5.9-7.1) mmol\/L as compared to the POC-BGA potassium concentration\nof 5.7 (5.5-6.8) mmol\/L with a mean difference of - 0.43 mmol\/L and 95% upper and lower limits of agreement of 0.35 mmol\/L and - 1.21\nmmol\/L, respectively. Regression analysis revealed proportional systematic error. Test for linearity did not indicate significant deviation (P = 0.297).\nConclusion: Although regression analysis indicated proportional systematic error, on Bland Altman analysis, the mean difference appeared to remain\nrelatively constant across the potassium range that was evaluated. Therefore, in patients presenting to the emergency department with a\nclinical suspicion of hyperkalaemia, POC-BGA potassium concentrations may be considered a surrogate for laboratory auto-analyser measurements\nonce clinicians have been cautioned about this difference.<\/jats:p>","DOI":"10.11613\/bm.2020.030702","type":"journal-article","created":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T07:42:25Z","timestamp":1596181345000},"page":"432-438","source":"Crossref","is-referenced-by-count":3,"title":["A method comparison study of a point-of-care blood gas analyser with a laboratory auto-analyser for the determination of potassium concentrations during hyperkalaemia in patients with kidney disease"],"prefix":"10.11613","volume":"30","author":[{"given":"Mogamat-Yazied","family":"Chothia","sequence":"first","affiliation":[{"name":"Division of Nephrology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patricia","family":"Kassum","sequence":"additional","affiliation":[{"name":"Division of Nephrology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annalise","family":"Zemlin","sequence":"additional","affiliation":[{"name":"Division of Chemical Pathology, Faculty of Medicine and Health Sciences, Stellenbosch University and National Health Laboratory Service (NHLS), Tygerberg Hospital, Cape Town, South Africa"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4885","published-online":{"date-parts":[[2020,10,12]]},"reference":[{"key":"key20200731034224_r1","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.2215\/CJN.08580813","article-title":"Regulation of potassium homeostasis.","volume":"10","author":"Palmer","year":"2015","journal-title":"Clin J Am Soc Nephrol"},{"key":"key20200731034224_r2","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.emc.2013.12.005","article-title":"Derangements of potassium.","volume":"32","author":"Medford-Davis","year":"2014","journal-title":"Emergency Medicine Clinics."},{"key":"key20200731034224_r3","doi-asserted-by":"crossref","first-page":"c8","DOI":"10.1159\/000329511","article-title":"Association of hypo-and hyperkalemia with disease progression and mortality in males with chronic kidney disease: the role of race.","volume":"120","author":"Hayes","year":"2012","journal-title":"Nephron Clin Pract"},{"key":"key20200731034224_r4","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.2215\/CJN.01150112","article-title":"Prevalence and factors associated with hyperkalemia in predialysis patients followed in a low-clearance clinic.","volume":"7","author":"Sarafidis","year":"2012","journal-title":"Clin J Am Soc Nephrol"},{"key":"key20200731034224_r5","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2012-002011","article-title":"Validity of the International Classification of Diseases 10th revision code for hyperkalaemia in elderly patients at presentation to an emergency department and at hospital admission.","volume":"2","author":"Fleet","year":"2012","journal-title":"BMJ Open"},{"key":"key20200731034224_r6","doi-asserted-by":"crossref","first-page":"531","DOI":"10.2215\/CJN.07821109","article-title":"Potassium homeostasis and renin-angiotensin-aldosterone system inhibitors.","volume":"5","author":"Weir","year":"2010","journal-title":"Clin J Am Soc Nephrol"},{"key":"key20200731034224_r7","doi-asserted-by":"crossref","first-page":"324","DOI":"10.2215\/CJN.04611007","article-title":"Retrospective review of the frequency of ECG changes in hyperkalemia.","volume":"3","author":"Montague","year":"2008","journal-title":"Clin J Am Soc Nephrol"},{"key":"key20200731034224_r8","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1016\/S0196-0644(05)81476-3","article-title":"The ability of physicians to predict hyperkalemia from the ECG.","volume":"20","author":"Wrenn","year":"1991","journal-title":"Ann Emerg Med"},{"key":"key20200731034224_r9","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s12245-009-0091-1","article-title":"Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes.","volume":"2","author":"Jain","year":"2009","journal-title":"Int J Emerg Med"},{"key":"key20200731034224_r10","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1136\/bmj.316.7137.1052","article-title":"Point of care testing: randomised controlled trial of clinical outcome.","volume":"316","author":"Kendall","year":"1998","journal-title":"BMJ"},{"key":"key20200731034224_r11","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1093\/clinchem\/42.5.711","article-title":"Impact of point-of-care testing on patients\u2019 length of stay in a large emergency department.","volume":"42","author":"Parvin","year":"1996","journal-title":"Clin Chem"},{"key":"key20200731034224_r12","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1016\/j.clinbiochem.2017.03.007","article-title":"Establishing evidence-based thresholds and laboratory practices to reduce inappropriate treatment of pseudohyperkalemia.","volume":"50","author":"Ranjitkar","year":"2017","journal-title":"Clin Biochem"},{"key":"key20200731034224_r13","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1007\/s12291-017-0657-2","article-title":"Errors in the Extra-Analytical Phases of Clinical Chemistry Laboratory Testing.","volume":"33","author":"Zemlin","year":"2018","journal-title":"Indian J Clin Biochem"},{"key":"key20200731034224_r14","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1136\/emj.2003.013599","article-title":"Agreement between an arterial blood gas analyser and a venous blood analyser in the measurement of potassium in patients in cardiac arrest.","volume":"22","author":"Johnston","year":"2005","journal-title":"Emerg Med J"},{"key":"key20200731034224_r15","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.hrtlng.2017.04.003","article-title":"Comparison of point-of-care versus central laboratory measurement of hematocrit, hemoglobin, and electrolyte concentrations.","volume":"46","author":"Gavala","year":"2017","journal-title":"Heart Lung"},{"key":"key20200731034224_r16","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.3349\/ymj.2014.55.5.1348","article-title":"Evaluating the utility of rapid point-of-care potassium testing for the early identification of hyperkalemia in patients with chronic kidney disease in the emergency department.","volume":"55","author":"You","year":"2014","journal-title":"Yonsei Med J"},{"key":"key20200731034224_r17","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1016\/j.resuscitation.2011.08.010","article-title":"Potassium values in cardiac arrest patients measured with a point-of-care blood gas analyzer.","volume":"82","author":"Ahn","year":"2011","journal-title":"Resuscitation"},{"key":"key20200731034224_r18","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.ajem.2016.01.003","article-title":"Agreement of serum potassium measured by blood gas and biochemistry analyzer in patients with moderate to severe hyperkalemia.","volume":"34","author":"Acikgoz","year":"2016","journal-title":"Am J Emerg Med"},{"key":"key20200731034224_r19","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.1515\/cclm-2018-0602","article-title":"Joint EFLM-COLABIOCLI Recommendation for venous blood sampling.","volume":"56","author":"Simundic","year":"2018","journal-title":"Clin Chem Lab Med"},{"key":"key20200731034224_r20","unstructured":"Westgard QC. Desirable Biological Variation Database specifications 2019. Available from: https:\/\/www.westgard.com\/biodatabase1.htm. Accessed March 19th 2020."},{"key":"key20200731034224_r21","doi-asserted-by":"crossref","first-page":"49","DOI":"10.11613\/BM.2011.010","article-title":"Comparison of methods: Passing and Bablok regression.","volume":"21","author":"Bili\u0107-Zulle","year":"2011","journal-title":"Biochem Med (Zagreb)"},{"key":"key20200731034224_r22","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.nefro.2019.06.002","article-title":"A novel point-of-care device for blood potassium detection of patients on dialysis: Comparison with a reference method.","volume":"40","author":"Novell","year":"2020","journal-title":"Nefrologia"},{"key":"key20200731034224_r23","doi-asserted-by":"crossref","first-page":"97","DOI":"10.3109\/00365513.2014.981854","article-title":"Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer.","volume":"75","author":"Uyanik","year":"2015","journal-title":"Scand J Clin Lab Invest"},{"key":"key20200731034224_r24","doi-asserted-by":"crossref","first-page":"145","DOI":"10.2147\/IJGM.S135788","article-title":"Inter-instrumental comparison for the measurement of electrolytes in patients admitted to the intensive care unit.","volume":"10","author":"Pant","year":"2017","journal-title":"Int J Gen Med"},{"key":"key20200731034224_r25","doi-asserted-by":"crossref","first-page":"233","DOI":"10.4103\/0972-5229.180044","article-title":"Are sodium and potassium results on arterial blood gas analyzer equivalent to those on electrolyte analyzer?","volume":"20","author":"Gupta","year":"2016","journal-title":"Indian J Crit Care Med"},{"key":"key20200731034224_r26","doi-asserted-by":"crossref","first-page":"224","DOI":"10.7196\/SAMJ.2018.v108i3.12626","article-title":"The effect of different forms of heparin on point-of-care blood gas analysis.","volume":"108","author":"Sandler","year":"2018","journal-title":"S Afr Med J"},{"key":"key20200731034224_r27","first-page":"39","article-title":"Potassium\u2013reference intervals for lithium-heparin plasma and serum from a population-based cohort.","volume":"34","author":"Drogies","year":"2010","journal-title":"Lab Med"},{"key":"key20200731034224_r28","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1056\/NEJM199110103251515","article-title":"Pseudohyperkalemia and platelet counts.","volume":"325","author":"Nijsten","year":"1991","journal-title":"N Engl J Med"}],"container-title":["Biochemia medica"],"original-title":[],"link":[{"URL":"https:\/\/www.biochemia-medica.com\/en\/journal\/30\/3\/10.11613\/BM.2020.030702\/fullArticle","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,13]],"date-time":"2020-10-13T11:24:47Z","timestamp":1602588287000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.biochemia-medica.com\/en\/journal\/30\/3\/10.11613\/BM.2020.030702"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,12]]},"references-count":28,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,10,12]]},"published-print":{"date-parts":[[2020,10,15]]}},"URL":"https:\/\/doi.org\/10.11613\/bm.2020.030702","relation":{},"ISSN":["1846-7482","1330-0962"],"issn-type":[{"value":"1846-7482","type":"electronic"},{"value":"1330-0962","type":"print"}],"subject":[],"published":{"date-parts":[[2020,10,12]]}}}