{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,1,25]],"date-time":"2024-01-25T15:01:26Z","timestamp":1706194886573},"reference-count":13,"publisher":"MIT Press - Journals","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Presence: Teleoperators &amp; Virtual Environments"],"published-print":{"date-parts":[[2005,10]]},"abstract":"<jats:p> Head-mounted display design is an iterative process. As such, a standardized user-centered assessment protocol of head-mounted performance during each phase of prototype development should be employed. In this paper, we first describe a methodology for assessing prototype head-mounted displays and virtual environments using visual performance metrics. We then present an application of the methodology using a prototype of a projection head-mounted display and the first module of our assessment: resolution visual acuity as a function of contrast. To evaluate the total system, we also used three different light levels and two different types of projection materials. Results from both studies indicate that the visual acuity metric resolution accurately identified reductions in user visual acuity caused by parameters of the projection display and those of the phase conjugate material. Results further support the need for benchmark metrics that allow comparison of prototype head-mounted performance through each stage of design. <\/jats:p>","DOI":"10.1162\/105474605774918697","type":"journal-article","created":{"date-parts":[[2005,11,25]],"date-time":"2005-11-25T22:52:33Z","timestamp":1132959153000},"page":"550-562","source":"Crossref","is-referenced-by-count":11,"title":["Methodology for the Iterative Evaluation of Prototype Head-Mounted Displays in Virtual Environments: Visual Acuity Metrics"],"prefix":"10.1162","volume":"14","author":[{"given":"Cali","family":"Fidopiastis","sequence":"first","affiliation":[{"name":"Optical Diagnostics and Applications (ODA) Laboratory, University of Central Florida, Institute for Simulation and Training and College of Optics and Photonics, 4000 Central Florida Boulevard, Orlando, FL 32816-2700"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Fuhrman","sequence":"additional","affiliation":[{"name":"Optical Diagnostics and Applications (ODA) Laboratory, College of Optics and Photonics, University of Central Florida 4000 Central Florida Boulevard, Orlando, FL 32816-2700"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Catherine","family":"Meyer","sequence":"additional","affiliation":[{"name":"Optical Diagnostics and Applications (ODA) Laboratory, College of Optics and Photonics, University of Central Florida 4000 Central Florida Boulevard, Orlando, FL 32816-2700"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jannick","family":"Rolland","sequence":"additional","affiliation":[{"name":"Optical Diagnostics and Applications (ODA) Laboratory, College of Optics and Photonics, Institute for Simulation and Training, University of Central Florida, 4000 Central Florida Boulevard, Orlando, FL 32816-2700"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"281","reference":[{"key":"p_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1745-459X.1998.tb00079.x"},{"key":"p_6","doi-asserted-by":"publisher","DOI":"10.1109\/MCG.2003.1185574"},{"key":"p_7","first-page":"399","volume":"5079","author":"Fidopiastis C. M.","year":"2003","journal-title":"Proceedings of the SPIE Aerosense: Helmet and Head-Mounted Displays VIII: Technologies and Applications"},{"key":"p_11","doi-asserted-by":"publisher","DOI":"10.1364\/AO.39.003814"},{"key":"p_12","doi-asserted-by":"publisher","DOI":"10.1364\/AO.42.000097"},{"key":"p_13","doi-asserted-by":"publisher","DOI":"10.3758\/BF03194550"},{"key":"p_17","doi-asserted-by":"publisher","DOI":"10.1162\/pres.1994.3.2.145"},{"key":"p_18","doi-asserted-by":"publisher","DOI":"10.3758\/BF03202110"},{"key":"p_19","first-page":"277","volume":"5079","author":"Martins R.","year":"2003","journal-title":"Proceedings of the SPIE Aerosense: Helmet and Head-Mounted Displays VIII: Technologies and Applications"},{"key":"p_24","first-page":"103","volume":"41","author":"National Academy of Sciences.","year":"1980","journal-title":"Advances in Ophthalmology"},{"key":"p_30","doi-asserted-by":"publisher","DOI":"10.1162\/105474605774918741"},{"key":"p_35","first-page":"297","volume":"22","author":"Task H. L.","year":"1991","journal-title":"Society for Information Display International Symposium Digest of Technical Papers"},{"key":"p_37","doi-asserted-by":"publisher","DOI":"10.3758\/BF03202828"}],"container-title":["Presence: Teleoperators and Virtual Environments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mitpressjournals.org\/doi\/pdf\/10.1162\/105474605774918697","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,12]],"date-time":"2021-03-12T21:28:34Z","timestamp":1615584514000},"score":1,"resource":{"primary":{"URL":"https:\/\/direct.mit.edu\/pvar\/article\/14\/5\/550-562\/18572"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,10]]},"references-count":13,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,10]]}},"alternative-id":["10.1162\/105474605774918697"],"URL":"https:\/\/doi.org\/10.1162\/105474605774918697","relation":{},"ISSN":["1054-7460"],"issn-type":[{"value":"1054-7460","type":"print"}],"subject":[],"published":{"date-parts":[[2005,10]]}}}