{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T07:49:58Z","timestamp":1773128998445,"version":"3.50.1"},"reference-count":14,"publisher":"Medknow","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["smedj"],"published-print":{"date-parts":[[2019,8]]},"DOI":"10.11622\/smedj.2019031","type":"journal-article","created":{"date-parts":[[2019,3,11]],"date-time":"2019-03-11T09:04:03Z","timestamp":1552295043000},"page":"432-435","source":"Crossref","is-referenced-by-count":21,"title":["The effects of gel-based manicure on pulse oximetry"],"prefix":"10.4103","volume":"60","author":[{"given":"JLJ","family":"Yek","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HR","family":"Abdullah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J","family":"Goh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"YW","family":"Chan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2581","published-online":{"date-parts":[[2019,8]]},"reference":[{"key":"ref0","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.resuscitation.2006.11.018","article-title":"Artificial acrylic finger nails may alter pulse oximetry measurement","volume":"74","author":"Hinkelbein","year":"2007","unstructured":"1. Hinkelbein J, Koehler H, Genzwuerker HV, Fiedler F. Artificial acrylic finger nails may alter pulse oximetry measurement. Resuscitation 2007; 74:75-82.","journal-title":"Resuscitation"},{"key":"ref1","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1111\/j.1365-2044.1991.tb11501.x","article-title":"III: Effects of interference, dyes, dyshaemoglobins and other pigments","volume":"46","author":"Ralston","year":"1991","unstructured":"2. Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. III: Effects of interference, dyes, dyshaemoglobins and other pigments. Anaesthesia 1991; 46:291-5.","journal-title":"Anaesthesia"},{"key":"ref2","unstructured":"3. Rieder EA, Tosti A. Cosmetically induced disorders of the nail with update on contemporary nail manicures. J Clin Aesthet Dermatol 2016; 9:39-44."},{"key":"ref3","doi-asserted-by":"publisher","unstructured":"4. Cot\u00e9 CJ, Goldstein EA, Fuchsman WH, Hoaglin DC. The effect of nail polish on pulse oximetry. Anesth Analg 1988; 67:683-6.","DOI":"10.1213\/00000539-198807000-00013"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1097\/00000542-198805000-00049","article-title":"Nail polish color can affect pulse oximeter saturation","volume":"68","author":"Rubin","year":"1988","unstructured":"5. Rubin AS. Nail polish color can affect pulse oximeter saturation. Anesthesiology 1988; 68:825.","journal-title":"Anesthesiology"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.resuscitation.2006.06.024","article-title":"Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients","volume":"72","author":"Hinkelbein","year":"2007","unstructured":"6. Hinkelbein J, Genzwuerker HV, Sogl R, Fiedler F. Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients. Resuscitation 2007; 72:82-91.","journal-title":"Resuscitation"},{"key":"ref6","unstructured":"7. Yamamoto LG, Yamamoto JA, Yamamoto JB, Yamamoto BE, Yamamoto PP. Nail polish does not significantly affect pulse oximetry measurements in mildly hypoxic subjects. Respir Care 2008; 53:1470-4."},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"8. Schulz KF, Altman DG, Moher D; CONSORT Group. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. Int J Surg 2011; 672-7.","DOI":"10.1016\/j.ijsu.2011.09.004"},{"key":"ref8","unstructured":"9. Urbaniak GC, Plous S. Research Randomizer (version 4.0). Available at: http:\/\/www.randomizer.org\/. Accessed June 22, 2013."},{"key":"ref9","unstructured":"10. Zhang Z. Missing data imputation: focusing on single imputation. Ann Transl Med 2016; 4:9."},{"key":"ref10","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"JM","year":"1999","unstructured":"11. Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8:135-60.","journal-title":"Stat Methods Med Res"},{"key":"ref11","doi-asserted-by":"publisher","unstructured":"12. Rodden AM, Spicer L, Diaz VA, Steyer TE. Does fingernail polish affect pulse oximeter readings? Intensive Critical Care Nurs 2007; 23:51-5.","DOI":"10.1016\/j.iccn.2006.08.006"},{"key":"ref12","unstructured":"13. Cairo JM, Pilbeam SP. Mosby's Respiratory Care Equipment. 8th ed. St Louis, MO: Mosby\/Elsevier, 2010."},{"key":"ref13","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1097\/00000542-199009000-00025","article-title":"Pulse oximeter failure thresholds in hypotension and vasoconstriction","volume":"73","author":"JW","year":"1990","unstructured":"14. Severinghaus JW, Spellman MJ Jr. Pulse oximeter failure thresholds in hypotension and vasoconstriction. Anesthesiology 1990; 73:532-7.","journal-title":"Anesthesiology"}],"container-title":["Singapore Medical Journal"],"original-title":[],"link":[{"URL":"http:\/\/www.smj.org.sg\/article\/effects-gel-based-manicure-pulse-oximetry","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,9]],"date-time":"2022-08-09T10:49:44Z","timestamp":1660042184000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.smj.org.sg\/article\/effects-gel-based-manicure-pulse-oximetry"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":14,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2019,8]]},"published-print":{"date-parts":[[2019,8]]}},"URL":"https:\/\/doi.org\/10.11622\/smedj.2019031","relation":{},"ISSN":["0037-5675"],"issn-type":[{"value":"0037-5675","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}