{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T21:06:41Z","timestamp":1791320801486,"version":"4.3.1"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[1999,1,1]],"date-time":"1999-01-01T00:00:00Z","timestamp":915148800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1999,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>We attempted to resolve the discrepancies in reported data on aerosol deposition from a chlorofluorocarbon (CFC)-propelled metered-dose inhaler (MDI) during mechanical ventilation, obtained by in vivo and in vitro methodologies. Albuterol delivery to the lower respiratory tract was decreased in a humidified versus a dry circuit (16.2 versus 30.4%, respectively; p &amp;lt; 0.01). In 10 mechanically ventilated patients, 4.8% of the nominal dose was exhaled. When the exhaled aerosol was subtracted from the in vitro delivery of 16.2% achieved in a humidified ventilator circuit, the resulting value (16.2 \u2212 4.8 = 11.4%) was similar to in vivo estimates of aerosol deposition. Having reconciled in vitro with in vivo findings, we then evaluated factors influencing aerosol delivery. A lower inspiratory flow rate (40 versus 80 L\/min; p &amp;lt; 0.001), a longer duty cycle (0.50 versus 0.25; p &amp;lt; 0.04), and a shorter interval between successive MDI actuations (15 versus 60 s; p &amp;lt; 0.02) increased aerosol delivery, whereas use of a hydrofluoroalkane (HFA)-propelled MDI decreased aerosol delivery compared with the CFC-propelled MDI. A MDI and actuator combination other than that designed by the manufacturer altered aerosol particle size and decreased drug delivery. In conclusion, aerosol delivery in an in vitro model accurately reflects in vivo delivery, providing a means for investigating methods to improve the efficiency of aerosol therapy during mechanical ventilation.<\/jats:p>","DOI":"10.1164\/ajrccm.159.1.9803119","type":"journal-article","created":{"date-parts":[[2013,4,4]],"date-time":"2013-04-04T13:52:29Z","timestamp":1365083549000},"page":"63-68","source":"Crossref","is-referenced-by-count":107,"title":["Reconciling\n                    <i>In Vitro<\/i>\n                    and\n                    <i>In Vivo<\/i>\n                    Measurements of Aerosol Delivery from a Metered-Dose Inhaler during Mechanical Ventilation and Defining Efficiency-enhancing Factors"],"prefix":"10.1093","volume":"159","author":[{"given":"JAMES B.","family":"FINK","sequence":"first","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Hines Veterans Administration Hospital, and Loyola University of Chicago Stritch School of Medicine, Hines, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"RAJIV","family":"DHAND","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Hines Veterans Administration Hospital, and Loyola University of Chicago Stritch School of Medicine, Hines, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JERRY","family":"GRYCHOWSKI","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Hines Veterans Administration Hospital, and Loyola University of Chicago Stritch School of Medicine, Hines, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"PATRICK J.","family":"FAHEY","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Hines Veterans Administration Hospital, and Loyola University of Chicago Stritch School of Medicine, Hines, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MARTIN J.","family":"TOBIN","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Hines Veterans Administration Hospital, and Loyola University of Chicago Stritch School of Medicine, Hines, Illinois"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[1999,1,1]]},"reference":[{"key":"2026032708585123400_B1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1164\/ajrccm.156.1.9610025","article-title":"Inhaled bronchodilator therapy in mechanically ventilated patients.","volume":"156","author":"Dhand","year":"1997","journal-title":"Am. J. Respir. Crit. Care Med"},{"key":"2026032708585123400_B2","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1378\/chest.107.1.210","article-title":"Treatment of bronchospasm by metered-dose inhaler in mechanically ventilated patients.","volume":"107","author":"Manthous","year":"1995","journal-title":"Chest"},{"key":"2026032708585123400_B3","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1089\/jam.1992.5.251","article-title":"Aerosol delivery during mechanical ventilation: a predictive in vitro lung model.","volume":"5","author":"Fuller","year":"1992","journal-title":"J. Aerosol Med."},{"key":"2026032708585123400_B4","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1378\/chest.102.3.924","article-title":"Evaluation of a reservoir device for metered-dose bronchodilator delivery to intubated adults: an in vitro study.","volume":"102","author":"Rau","year":"1992","journal-title":"Chest"},{"key":"2026032708585123400_B5","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1164\/ajrccm\/145.5.1117","article-title":"Nebulizer function during mechanical ventilation.","volume":"145","author":"O'Riordan","year":"1992","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708585123400_B6","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1164\/ajrccm\/146.2.383","article-title":"Delivery of a nebulized aerosol to a lung model during mechanical ventilation: effect of ventilator settings and nebulizer type, position, and volume of fill.","volume":"146","author":"O'Doherty","year":"1992","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708585123400_B7","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1164\/ajrccm\/148.4_Pt_1.872","article-title":"Delivery of ultrasonic nebulized aerosols to a lung model during mechanical ventilation.","volume":"148","author":"Thomas","year":"1993","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708585123400_B8","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1164\/ajrccm.152.4.7551401","article-title":"Albuterol delivery in a model of mechanical ventilation: comparison of metered-dose inhaler and nebulizer efficiency.","volume":"152","author":"Diot","year":"1995","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B9","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1164\/ajrccm.154.2.8756810","article-title":"Deposition of aerosol from metered-dose inhaler during mechanical ventilation: an in vitro model.","volume":"154","author":"Fink","year":"1996","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B10","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/00003246-198502000-00005","article-title":"Aerosol delivery in intubated, mechanically ventilated patients.","volume":"13","author":"MacIntyre","year":"1985","journal-title":"Crit. Care Med."},{"key":"2026032708585123400_B11","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1164\/ajrccm\/141.2.440","article-title":"Pressurized aerosol versus jet aerosol delivery to mechanically ventilated patients: comparison of dose to the lungs.","volume":"141","author":"Fuller","year":"1990","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708585123400_B12","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1136\/thx.48.2.154","article-title":"Pulmonary deposition of a nebulized aerosol during mechanical ventilation.","volume":"48","author":"Thomas","year":"1993","journal-title":"Thorax"},{"key":"2026032708585123400_B13","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1378\/chest.105.1.214","article-title":"Efficiency of bronchodilator aerosol delivery to the lungs from the metered dose inhaler in mechanically ventilated patients: a study comparing four different actuator devices.","volume":"105","author":"Fuller","year":"1994","journal-title":"Chest"},{"key":"2026032708585123400_B14","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/0378-5173(80)90112-X","article-title":"Fraction of dose exhaled after administration of pressurized inhalation aerosols.","volume":"6","author":"Moren","year":"1980","journal-title":"Int. J. Pharm."},{"key":"2026032708585123400_B15","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1164\/ajrccm.149.1.8111585","article-title":"Aerosol deposition in mechanically ventilated patients: optimizing nebulizer delivery.","volume":"149","author":"O'Riordan","year":"1994","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B16"},{"key":"2026032708585123400_B17","doi-asserted-by":"crossref","first-page":"1827","DOI":"10.1164\/ajrccm.151.6.7767526","article-title":"Bronchodilator delivery by metered-dose inhaler in ventilator-supported patients.","volume":"151","author":"Dhand","year":"1995","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B18","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1164\/ajrccm.154.2.8756811","article-title":"Dose response to bronchodilator delivered by metered-dose inhaler in ventilator-supported patients.","volume":"154","author":"Dhand","year":"1996","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B19","first-page":"88","article-title":"Aerosol characterization and deposition.","volume":"110","author":"Morrow","year":"1974","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708585123400_B20","first-page":"137","article-title":"Size aspects of metered-dose inhaler aerosols.","volume":"132","author":"Kim","year":"1985","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708585123400_B21","first-page":"A436","article-title":"Pattern of deposition and aerosol particle size in a humidified ventilator circuit using metered dose inhaler and spacer (abstract).","volume":"151","author":"Fink","year":"1995","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B22","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/S0091-6749(95)70208-3","article-title":"Choosing the metered-dose inhaler spacer or holding chamber that matches the patient's need: evidence that the specific drug being delivered is an important consideration.","volume":"96","author":"Ahrens","year":"1995","journal-title":"J. Allergy Clin. Immunol."},{"key":"2026032708585123400_B23","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.1164\/ajrccm.155.6.9196100","article-title":"Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea.","volume":"155","author":"Leung","year":"1997","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708585123400_B24","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1002\/j.1875-9114.1993.tb02730.x","article-title":"In vitro evaluation of the effect of metered-dose inhaler administration technique on aerosolized drug delivery.","volume":"13","author":"Shalansky","year":"1993","journal-title":"Pharmacotherapy"}],"container-title":["American Journal of Respiratory and Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/159\/1\/63\/67429218\/ajrccm_159_1_63.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/159\/1\/63\/67429218\/ajrccm_159_1_63.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T12:59:02Z","timestamp":1774616342000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ajrccm\/article\/159\/1\/63\/8529968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,1,1]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[1999,1,1]]},"published-print":{"date-parts":[[1999,1,1]]}},"URL":"https:\/\/doi.org\/10.1164\/ajrccm.159.1.9803119","relation":{},"ISSN":["1073-449X","1535-4970"],"issn-type":[{"value":"1073-449X","type":"print"},{"value":"1535-4970","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[1999,1]]},"published":{"date-parts":[[1999,1,1]]}}}