{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T03:27:22Z","timestamp":1787887642320,"version":"build-2784847793"},"reference-count":30,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2000,1,1]],"date-time":"2000-01-01T00:00:00Z","timestamp":946684800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2000,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The cost of mechanical ventilation (MV) is high. Efforts to reduce this cost, as long as they are not detrimental for the patients, are needed. MV with heat and moisture exchangers (HME) changed every 48 h is safe, efficient, and cost-effective. Preliminary reports suggest that the life span of these filters may be prolonged. We determined prospectively whether a hygroscopic and hydrophobic HME (Hygrobac-Dar; Mallinckrodt) provided safe and efficient heating and humidification of the inspired gases when changed only once a week. Patients who were considered to require mechanical ventilation for more than 48 h were included in the study. HMEs were initially set for 7 d. Efficient airway heating and humidification were assessed by clinical parameters (number of tracheal suctionings and instillations required, peak airway pressures) and hygrometric measurements performed by psychrometry. Resistance was measured from Day 0 to Day 7. Bacterial colonization of circuits and HMEs was studied. A total of 377 days of mechanical ventilation with 60 HMEs was studied. Clinical parameters and hygrometric measurements did not change between Day 0 and Day 7. Mean absolute humidity was 30.3 \u00b1 1.3 mg H2O\/L on Day 0 and 30.8 \u00b1 1.5 mg H2O\/L on Day 7 (p = 0.7). Endotracheal tube occlusion never occurred. Three HMEs were replaced prematurely because of insufficient absolute humidity. This rare event occurred only in patients with COPD and after the third day of use. In addition, the absolute humidity delivered by the HMEs was significantly lower in patients with COPD than in the rest of the population. Resistance did not change from Day 0 to Day 7 (2.4 \u00b1 0.3 versus 2.7 \u00b1 0.3 cm H2O\/L\/s; p = 0.4). Bacterial samples of both circuits and ventilator sides of HMEs were sterile in most cases. We conclude that mechanical ventilation can be safely conducted in non-COPD patients using an HME changed only once a week, leading to substantial cost savings (about $110,000 per year if these findings were applied to the university-affiliated hospitals in Paris). Ricard J-D, Le Mi\u00e8re E, Markowicz P, Lasry S, Saumon G, Djeda\u00efni K, Coste F, Dreyfuss D. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.<\/jats:p>","DOI":"10.1164\/ajrccm.161.1.9902062","type":"journal-article","created":{"date-parts":[[2013,4,4]],"date-time":"2013-04-04T14:08:10Z","timestamp":1365084490000},"page":"104-109","source":"Crossref","is-referenced-by-count":88,"title":["Efficiency and Safety of Mechanical Ventilation with a Heat and Moisture Exchanger Changed Only Once a Week"],"prefix":"10.1093","volume":"161","author":[{"given":"JEAN-DAMIEN","family":"RICARD","sequence":"first","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ERIC","family":"LE MI\u00c8RE","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"PHILIPPE","family":"MARKOWICZ","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"SERGE","family":"LASRY","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"GEORGES","family":"SAUMON","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KAMEL","family":"DJEDA\u00cfNI","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FRAN\u00c7OIS","family":"COSTE","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DIDIER","family":"DREYFUSS","sequence":"additional","affiliation":[{"name":"Service de R\u00e9animation M\u00e9dicale et de Bact\u00e9riologie, H\u00f4pital Louis Mourier (Assistance Publique-H\u00f4pitaux de Paris), Colombes, France; and Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale, Unit\u00e9 82, Facult\u00e9 de M\u00e9decine Xavier Bichat, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2000,1,1]]},"reference":[{"key":"2026032708344652500_B1","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00000542-197903000-00005","article-title":"Humidity and the anesthetized patient.","volume":"50","author":"Chalon","year":"1979","journal-title":"Anesthesiology"},{"key":"2026032708344652500_B2","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1093\/bja\/46.1.29","article-title":"Temperature, humidity and mucus flow in the intubated trachea.","volume":"46","author":"Forbes","year":"1974","journal-title":"Br. J. Anaesth."},{"key":"2026032708344652500_B3","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1056\/NEJM198206243062501","article-title":"Contamination of mechanical ventilators with tubing changes every 24 or 48 hours.","volume":"306","author":"Craven","year":"1982","journal-title":"N. Engl. J. Med."},{"key":"2026032708344652500_B4","first-page":"625","article-title":"Contaminated condensate in mechanical ventilator circuits: a risk for nosocomial pneumonia.","volume":"129","author":"Craven","year":"1984","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708344652500_B5","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1164\/ajrccm\/143.4_Pt_1.738","article-title":"Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change.","volume":"143","author":"Dreyfuss","year":"1991","journal-title":"Am. Rev. Respir. Dis."},{"key":"2026032708344652500_B6","first-page":"5","article-title":"Filtre \u00e9changeurs de chaleur et d'humidit\u00e9 versus humidificateurs chauffant en ventilation m\u00e9canique.","volume":"5","author":"Tenaillon","year":"1989","journal-title":"R\u00e9an Soins Intens. M\u00e9d. Urg."},{"key":"2026032708344652500_B7","first-page":"986","article-title":"Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia.","volume":"151","author":"Dreyfuss","year":"1995","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708344652500_B8","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1378\/chest.111.3.686","article-title":"Safety of combined heat and moisture exchangers in long-term mechanical ventilation.","volume":"111","author":"Hurni","year":"1997","journal-title":"Chest"},{"key":"2026032708344652500_B9","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1007\/BF01705040","article-title":"Comparison of hydrophobic heat and moisture exchangers with heated humidifiers during prolonged mechanical ventilation.","volume":"18","author":"Roustan","year":"1992","journal-title":"Intensive Care Med."},{"key":"2026032708344652500_B10","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1097\/00000542-199612000-00015","article-title":"Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.","volume":"85","author":"Villafane","year":"1996","journal-title":"Anesthesiology"},{"key":"2026032708344652500_B11","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1378\/chest.97.1.144","article-title":"Heat and moisture exchangers and vaporizing humidifiers in the intensive unit.","volume":"97","author":"Martin","year":"1990","journal-title":"Chest"},{"key":"2026032708344652500_B12","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/00003246-198803000-00013","article-title":"Endotracheal tube occlusions associated with the use of heat and moisture exchangers in the intensive care unit.","volume":"16","author":"Cohen","year":"1988","journal-title":"Crit. Care Med."},{"key":"2026032708344652500_B13","doi-asserted-by":"crossref","first-page":"1562","DOI":"10.1164\/ajrccm.152.5.7582295","article-title":"Changing heat and moisture exchangers every 48 hours rather 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia.","volume":"152","author":"Djeda\u00efni","year":"1995","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708344652500_B14"},{"key":"2026032708344652500_B15","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1007\/BF01706470","article-title":"An evaluation of the heat and moisture performance of four ventilator circuit filters.","volume":"18","author":"Jackson. C., and A. Webb","year":"1992","journal-title":"Intensive Care Med."},{"key":"2026032708344652500_B16","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1378\/chest.102.5.1347","article-title":"Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation &gt; 10 L\/min.","volume":"102","author":"Martin","year":"1992","journal-title":"Chest"},{"key":"2026032708344652500_B17","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1378\/chest.107.5.1411","article-title":"Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L\/min.","volume":"107","author":"Martin","year":"1995","journal-title":"Chest"},{"key":"2026032708344652500_B18","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1378\/chest.104.1.220","article-title":"Comparative evaluation of three heat and moisture exchangers during short-term postoperative mechanical ventilation.","volume":"104","author":"Sottiaux","year":"1993","journal-title":"Chest"},{"key":"2026032708344652500_B19","first-page":"1","article-title":"Humidifiers for medical use: heat and moisture exchangers. Draft International Standards (ISO\/DIS 9360, 1988). International Organization for Standardization.","volume":"121","author":"International Organization for Standardization","year":"1988","journal-title":"Technical Committee"},{"key":"2026032708344652500_B20","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/0002-9343(74)90440-9","article-title":"Complications of assisted ventilation: a prospective study of 354 consecutives episodes.","volume":"57","author":"Zwillich","year":"1974","journal-title":"Am. J. Med."},{"key":"2026032708344652500_B21","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1097\/00003246-198411000-00012","article-title":"A simplified acute physiologic score for ICU patients.","volume":"12","author":"Legall","year":"1984","journal-title":"Crit. Care Med."},{"key":"2026032708344652500_B22","first-page":"261","article-title":"Heat and moisture exchangers: structure and function.","volume":"4","author":"Wilkes","year":"1998","journal-title":"Respir. Care Clin. N. Am."},{"key":"2026032708344652500_B23","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1378\/chest.100.1.160","article-title":"Heat and moisture exchangers vs heated humidifier during mechanical ventilation.","volume":"100","author":"Misset","year":"1991","journal-title":"Chest"},{"key":"2026032708344652500_B24","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1093\/bja\/66.2.258","article-title":"Resistance of humidifiers, and inspiratory work imposed by a ventilator-humidifier circuit.","volume":"66","author":"Oh","year":"1991","journal-title":"Br. J. Anaesth."},{"key":"2026032708344652500_B25","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1378\/chest.110.5.1294","article-title":"Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation.","volume":"110","author":"Le Bourdell\u00e8s","year":"1996","journal-title":"Chest"},{"key":"2026032708344652500_B26","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1097\/00003246-199607000-00020","article-title":"Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure.","volume":"24","author":"Pelosi","year":"1996","journal-title":"Crit. Care Med."},{"key":"2026032708344652500_B27","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1378\/chest.113.3.759","article-title":"A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients.","volume":"113","author":"Kollef","year":"1998","journal-title":"Chest"},{"key":"2026032708344652500_B28","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/00003246-199803000-00018","article-title":"Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours.","volume":"26","author":"Thomachot","year":"1998","journal-title":"Crit. Care Med."},{"key":"2026032708344652500_B29","first-page":"A47","article-title":"Clinical characteristics of patients receiving mechanical ventilation (abstract).","volume":"159","author":"Esteban","year":"1999","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2026032708344652500_B30","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1097\/00003246-199803000-00005","article-title":"Extended use of disposables: economically sound or asking for trouble? [Editorial].","volume":"26","author":"Durbin","year":"1998","journal-title":"Crit. Care Med."}],"container-title":["American Journal of Respiratory and Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/161\/1\/104\/67423520\/ajrccm_161_1_104.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/161\/1\/104\/67423520\/ajrccm_161_1_104.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T12:34:57Z","timestamp":1774614897000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ajrccm\/article\/161\/1\/104\/8527321"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,1,1]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2000,1,1]]},"published-print":{"date-parts":[[2000,1,1]]}},"URL":"https:\/\/doi.org\/10.1164\/ajrccm.161.1.9902062","relation":{},"ISSN":["1073-449X","1535-4970"],"issn-type":[{"value":"1073-449X","type":"print"},{"value":"1535-4970","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2000,1]]},"published":{"date-parts":[[2000,1,1]]}}}