{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:57:50Z","timestamp":1787018270481,"version":"build-2736575974"},"reference-count":19,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[2001,6,1]],"date-time":"2001-06-01T00:00:00Z","timestamp":991353600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2001,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Daytime somnolence is both a symptom in many patients and a prevalent complaint in the general population, but its objective assessment remains elusive. The current available tests are technically complex and thus inadequate for routine clinical use or epidemiological studies. A simplified behavioral maintenance of wakefulness test (OSLER test) has been recently described that could allow for widespread availability of objective measurements of this symptom. We verified the occurrence of (micro)sleep (episodes of sleep of \u2a7e 3 s duration) during the performance of the OSLER test in 10 normal subjects after a non\u2013sleep-deprived night and a sleep-deprived night in randomized order. Sleep was assessed electrophysiologically according to standard methods. The OSLER test (mean of four measurements) was significantly shorter after the sleep-deprived night (25 min versus 38 min). Single missed stimuli were frequent with or without (micro)sleep, but (micro)sleep was almost always present when four or more consecutive stimuli were missed. The sensitivity and specificity of the test in detecting sleep (of \u2a7e 3 s duration) are 85% and 94%, respectively. The total number of missed stimuli per minute duration of the test could add valuable information to the simpler mean test result. Sensitivity and specificity are not altered when only three measurements are performed. We conclude that the OSLER test appears as a simple, easy, and reliable method to objectively assess daytime somnolence.<\/jats:p>","DOI":"10.1164\/ajrccm.163.7.2007028","type":"journal-article","created":{"date-parts":[[2013,4,4]],"date-time":"2013-04-04T14:45:05Z","timestamp":1365086705000},"page":"1619-1625","source":"Crossref","is-referenced-by-count":81,"title":["Microsleep during a Simplified Maintenance of Wakefulness Test"],"prefix":"10.1093","volume":"163","author":[{"given":"BENOIT","family":"PRIEST","sequence":"first","affiliation":[{"name":"Pneumology and EEG Departments, Cliniques Universitaires Saint-Luc, Universit\u00e9 Catholique de Louvain, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"COLETTE","family":"BRICHARD","sequence":"additional","affiliation":[{"name":"Pneumology and EEG Departments, Cliniques Universitaires Saint-Luc, Universit\u00e9 Catholique de Louvain, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"GENEVIEVE","family":"AUBERT","sequence":"additional","affiliation":[{"name":"Pneumology and EEG Departments, Cliniques Universitaires Saint-Luc, Universit\u00e9 Catholique de Louvain, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"GIUSEPPE","family":"LIISTRO","sequence":"additional","affiliation":[{"name":"Pneumology and EEG Departments, Cliniques Universitaires Saint-Luc, Universit\u00e9 Catholique de Louvain, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DANIEL O.","family":"RODENSTEIN","sequence":"additional","affiliation":[{"name":"Pneumology and EEG Departments, Cliniques Universitaires Saint-Luc, Universit\u00e9 Catholique de Louvain, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2001,6,1]]},"reference":[{"key":"2026032708212467700_B1","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1093\/sleep\/14.6.540","article-title":"A new method for measuring daytime sleepiness: the Epworth sleepiness scale.","volume":"14","author":"Johns","year":"1991","journal-title":"Sleep"},{"key":"2026032708212467700_B2","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1111\/j.1469-8986.1973.tb00801.x","article-title":"Quantification of sleepiness: a new approach.","volume":"10","author":"Hoddes","year":"1973","journal-title":"Psychophysiology"},{"key":"2026032708212467700_B3","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/0013-4694(78)90162-1","article-title":"Excessive daytime sleepiness in man: multiple sleep latency measurement in narcoleptic and control subjects.","volume":"45","author":"Richardson","year":"1978","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"2026032708212467700_B4","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/0013-4694(82)90142-0","article-title":"Maintenance of wakefulness test: a polysomnographic technique for evaluation treatment efficacy in patients with excessive somnolence.","volume":"53","author":"Mitler","year":"1982","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"2026032708212467700_B5","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1378\/chest.101.4.898","article-title":"Maintenance of wakefulness test and multiple sleep latency test: measurement of different abilities in patients with sleep disorders.","volume":"101","author":"Sangal","year":"1992","journal-title":"Chest"},{"key":"2026032708212467700_B6","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1177\/155005949903000208","article-title":"Subjective and objective indices of sleepiness (ESS and MWT) are not equally useful in patients with sleep apnea.","volume":"30","author":"Sangal","year":"1999","journal-title":"Clin Electroencephalogr"},{"key":"2026032708212467700_B7","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1056\/NEJM199304293281704","article-title":"The occurrence of sleep-disordered breathing among middle-aged adults.","volume":"328","author":"Young","year":"1993","journal-title":"N Engl J Med"},{"key":"2026032708212467700_B8","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1164\/ajrccm.152.2.7633730","article-title":"A community study of snoring and sleep-disordered breathing: symptoms.","volume":"152","author":"Olson","year":"1995","journal-title":"Am J Respir Crit Care Med"},{"key":"2026032708212467700_B9","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1046\/j.1365-2869.1997.00039.x","article-title":"A behavioural test to assess daytime sleepiness in obstructive sleep apnoea.","volume":"6","author":"Bennett","year":"1997","journal-title":"J Sleep Res"},{"key":"2026032708212467700_B10"},{"key":"2026032708212467700_B11"},{"key":"2026032708212467700_B12","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/0013-4694(96)95612-6","article-title":"Occurrence of \u201cmicrosleeps\u201d during daytime sleep onset in normal subjects.","volume":"98","author":"Harrison","year":"1996","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"2026032708212467700_B13","first-page":"393","article-title":"Driving simulation with EEG monitoring in normal and obstructive sleep apnea patients.","volume":"23","author":"Risser","year":"2000","journal-title":"Sleep"},{"key":"2026032708212467700_B14","doi-asserted-by":"crossref","first-page":"697","DOI":"10.2466\/pms.1967.25.3.697","article-title":"Alpha and theta EEG in vigilance.","volume":"25","author":"Daniel","year":"1967","journal-title":"Percept Motor Skills"},{"key":"2026032708212467700_B15","first-page":"388","article-title":"A comparison of sleep detection by wrist actigraphy, behavioral response, and polysomnography.","volume":"20","author":"Blood","year":"1997","journal-title":"Sleep"},{"key":"2026032708212467700_B16","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1001\/jama.282.12.1157","article-title":"Capturing the patient's view of change as a clinical outcome measure.","volume":"282","author":"Fischer","year":"1999","journal-title":"JAMA"},{"key":"2026032708212467700_B17","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1164\/ajrccm.159.2.9803121","article-title":"Randomized placebo-controlled crossover trial of continuous positive airway pressure for mild sleep apnea\/hypopnea syndrome.","volume":"159","author":"Engleman","year":"1999","journal-title":"Am J Respir Crit Care Med"},{"key":"2026032708212467700_B18","doi-asserted-by":"crossref","first-page":"2100","DOI":"10.1016\/S0140-6736(98)10532-9","article-title":"Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial.","volume":"353","author":"Jenkinson","year":"1999","journal-title":"Lancet"},{"key":"2026032708212467700_B19","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1164\/ajrccm.158.1.9709135","article-title":"Automobile accidents in patients with sleep apnea syndrome: an epidemiological and mechanistic study.","volume":"158","author":"Barb\u00e9","year":"1998","journal-title":"Am J Respir Crit Care Med"}],"container-title":["American Journal of Respiratory and Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/163\/7\/1619\/67548997\/ajrccm_163_7_1619.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/163\/7\/1619\/67548997\/ajrccm_163_7_1619.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T12:21:29Z","timestamp":1774614089000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ajrccm\/article\/163\/7\/1619\/8541304"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,6,1]]},"references-count":19,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2001,6,1]]},"published-print":{"date-parts":[[2001,6,1]]}},"URL":"https:\/\/doi.org\/10.1164\/ajrccm.163.7.2007028","relation":{},"ISSN":["1073-449X","1535-4970"],"issn-type":[{"value":"1073-449X","type":"print"},{"value":"1535-4970","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2001,6]]},"published":{"date-parts":[[2001,6,1]]}}}