{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T03:21:49Z","timestamp":1794540109373,"version":"4.9.1"},"reference-count":44,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":["www.atsjournals.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Rationale<\/jats:title>\n                    <jats:p>High-flow therapy reduces dyspnea in acute respiratory failure, but the underlying mechanisms are not fully elucidated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>To compare dyspnea, we measured airway occlusion pressure (P0.1) and inspiratory work with and without nasal high flow (NHF; FiO2, 21%; temperature, 31\u00b0C) in intubated patients under pressure support ventilation and during a spontaneous breathing trial (SBT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Dyspnea (determined using numerical rating scale [NRS] and Mechanical Ventilation \u2013 Respiratory Distress Observational Scale [MV-RDOS] scores), P0.1, esophageal pressure, respiratory muscle EMG, and arterial blood gas were compared in intubated patients on pressure support ventilation presenting a dyspnea-NRS score higher than 3 during two sequences: 1) pressure support ventilation with NHF at 0 L\/min followed by 30, 50, and 60 L\/min (the last three were randomized) and 2) an SBT with NHF at 0 and 50 L\/min (randomized).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Measurements and Main Results<\/jats:title>\n                    <jats:p>Twenty patients were included. During pressure support ventilation, as compared with a dyspnea-NRS score of 5 (range\u2009=\u20094\u20136) at an NHF of 0 L\/min, dyspnea-NRS scores were 3 (range\u2009=\u20092\u20136) and 3 (range\u2009=\u20092\u20135) at NHFs of 30 L\/min and 50 L\/min, respectively (P\u2009&amp;lt;\u20090.05). However, there was no change in MV-RDOS score, P0.1, esophageal pressure, respiratory muscle EMG, and gas exchange. During the SBT, at an NHF of 50 L\/min, dyspnea-NRS score and P0.1 were lower than during the SBT at an NHF of 0 L\/min (P\u2009&amp;lt;\u20090.01 and P\u2009=\u20090.04, respectively), whereas MV-RDOS score, esophageal pressure, and respiratory muscle EMG did not change as compared with findings in an SBT with an NHF of 0 L\/min.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In orally intubated patients, NHF was associated with lower dyspnea and lower respiratory drive without affecting the inspiratory work.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1164\/rccm.202405-1057oc","type":"journal-article","created":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T17:12:14Z","timestamp":1734369134000},"page":"577-586","update-policy":"https:\/\/doi.org\/10.1164\/crossmarkpolicies","source":"Crossref","is-referenced-by-count":17,"title":["Nasal High Flow to Modulate Dyspnea in Orally Intubated Patients"],"prefix":"10.1093","volume":"211","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-3284-3018","authenticated-orcid":false,"given":"Valentine","family":"Le Stang","sequence":"first","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"},{"name":"Service de M\u00e9decine Intensive \u2013 R\u00e9animation (D\u00e9partement \u201cR3S\u201d) and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M\u00e9lodie","family":"Graverot","sequence":"additional","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"},{"name":"Service de M\u00e9decine Intensive \u2013 R\u00e9animation (D\u00e9partement \u201cR3S\u201d) and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5443-2074","authenticated-orcid":false,"given":"Antoine","family":"Kimmoun","sequence":"additional","affiliation":[{"name":"M\u00e9decine Intensive et R\u00e9animation Brabois, CHRU de Nancy, Universit\u00e9 de Lorraine, H\u02dbpitaux de Brabois (Vandoeuvre-les-Nancy) rue du Morvan, 54511 Vandoeuvre-les-Nancy Cedex; and"},{"name":"INSERM U1116, French Clinical Research Infrastructure Network, Investigation Network Initiative \u2013 Cardiovascular and Renal Clinical Trialists (FCRIN INI-CRCT), Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9370-7301","authenticated-orcid":false,"given":"Marie-C\u00e9cile","family":"Ni\u00e9rat","sequence":"additional","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3552-5053","authenticated-orcid":false,"given":"Maxens","family":"Decav\u00e8le","sequence":"additional","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"},{"name":"Service de M\u00e9decine Intensive \u2013 R\u00e9animation (D\u00e9partement \u201cR3S\u201d) and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2868-9279","authenticated-orcid":false,"given":"Thomas","family":"Similowski","sequence":"additional","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"},{"name":"D\u00e9partement \u201cR3S\u201d, AP-HP, H\u00f4pital Piti\u00e9-Salp\u00eatri\u00e8re, Sorbonne Universit\u00e9, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0432-7217","authenticated-orcid":false,"given":"Alexandre","family":"Demoule","sequence":"additional","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"},{"name":"Service de M\u00e9decine Intensive \u2013 R\u00e9animation (D\u00e9partement \u201cR3S\u201d) and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9191-6089","authenticated-orcid":false,"given":"Martin","family":"Dres","sequence":"additional","affiliation":[{"name":"Neurophysiologie respiratoire exp\u00e9rimentale et clinique, INSERM, UMRS1158, and"},{"name":"Service de M\u00e9decine Intensive \u2013 R\u00e9animation (D\u00e9partement \u201cR3S\u201d) and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2025,4,1]]},"reference":[{"key":"2026031105265509100_bib1","doi-asserted-by":"crossref","first-page":"2331","DOI":"10.1001\/jama.2015.5213","article-title":"High-flow nasal oxygen vs noninvasive positive airway pressure in hypoxemic patients after cardiothoracic surgery: a randomized clinical trial","volume":"313","author":"St\u00e9phan","year":"2015","journal-title":"JAMA"},{"key":"2026031105265509100_bib2","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1001\/jama.2019.14901","article-title":"Effect of postextubation high-flow nasal oxygen with noninvasive ventilation vs high-flow nasal oxygen alone on reintubation among patients at high risk of extubation failure: a randomized clinical trial","volume":"322","author":"Thille","year":"2019","journal-title":"JAMA"},{"key":"2026031105265509100_bib3","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1007\/s00134-019-05590-5","article-title":"High flow nasal cannula compared with conventional oxygen therapy for acute hypoxemic respiratory failure: a systematic review and meta-analysis","volume":"45","author":"Rochwerg","year":"2019","journal-title":"Intensive Care Med"},{"key":"2026031105265509100_bib4","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/s00134-023-07050-7","article-title":"ESICM guidelines on acute respiratory distress syndrome: definition, phenotyping and respiratory support strategies","volume":"49","author":"Grasselli","year":"2023","journal-title":"Intensive Care Med"},{"key":"2026031105265509100_bib5","doi-asserted-by":"crossref","first-page":"2101574","DOI":"10.1183\/13993003.01574-2021","article-title":"ERS clinical practice guidelines: high-flow nasal cannula in acute respiratory failure","volume":"59","author":"Oczkowski","year":"2022","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib6","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1007\/s00134-024-07386-8","article-title":"High-flow nasal cannula: evolving practices and novel clinical and physiological insights","volume":"50","author":"Roca","year":"2024","journal-title":"Intensive Care Med"},{"key":"2026031105265509100_bib7","doi-asserted-by":"crossref","first-page":"1580","DOI":"10.1152\/japplphysiol.00416.2021","article-title":"High-flow nasal cannula compared with continuous positive airway pressure: a bench and physiological study","volume":"132","author":"Vieira","year":"2022","journal-title":"J Appl Physiol"},{"key":"2026031105265509100_bib8","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/resp.14580","article-title":"Dyspnoea relief as an inherent benefit of high flow nasal cannula therapy: a laboratory randomized trial in healthy humans","volume":"29","author":"Bianquis","year":"2024","journal-title":"Respirology"},{"key":"2026031105265509100_bib9","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1164\/rccm.201605-0916OC","article-title":"Physiologic effects of high-flow nasal cannula in acute hypoxemic respiratory failure","volume":"195","author":"Mauri","year":"2017","journal-title":"Am J Respir Crit Care Med"},{"key":"2026031105265509100_bib10","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1097\/ALN.0000000000004010","article-title":"Respiratory drive in patients with sepsis and septic shock: modulation by high-flow nasal cannula","volume":"135","author":"Mauri","year":"2021","journal-title":"Anesthesiology"},{"key":"2026031105265509100_bib11","doi-asserted-by":"crossref","first-page":"1701383","DOI":"10.1183\/13993003.01383-2017","article-title":"Fooling the brain to alleviate dyspnoea","volume":"50","author":"Mor\u00e9lot-Panzini","year":"2017","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib12","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1164\/ajrccm\/136.1.58","article-title":"Cold facial stimulation reduces breathlessness induced in normal subjects","volume":"136","author":"Schwartzstein","year":"1987","journal-title":"Am Rev Respir Dis"},{"key":"2026031105265509100_bib13","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/j.jpainsymman.2009.09.024","article-title":"Does the use of a handheld fan improve chronic dyspnea? A randomized, controlled, crossover trial","volume":"39","author":"Galbraith","year":"2010","journal-title":"J Pain Symptom Manage"},{"key":"2026031105265509100_bib14","doi-asserted-by":"crossref","first-page":"2202215","DOI":"10.1183\/13993003.02215-2022","article-title":"Sensory interventions to relieve dyspnoea in critically ill mechanically ventilated patients","volume":"63","author":"Bureau","year":"2024","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib15","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/S0140-6736(07)61602-X","article-title":"The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies","volume":"370","author":"von Elm","year":"2007","journal-title":"Lancet"},{"key":"2026031105265509100_bib16","doi-asserted-by":"crossref","first-page":"2300347","DOI":"10.1183\/13993003.00347-2023","article-title":"Dyspnoea in acutely ill mechanically ventilated adult patients: an ERS\/ESICM statement","volume":"63","author":"Demoule","year":"2024","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib17","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1183\/09031936.00010206","article-title":"Weaning from mechanical ventilation","volume":"29","author":"Boles","year":"2007","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib18","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1164\/rccm.202301-0188OC","article-title":"Interventions relieving dyspnea in intubated patients show responsiveness of the Mechanical Ventilation\u2013Respiratory Distress Observation Scale","volume":"208","author":"Decav\u00e8le","year":"2023","journal-title":"Am J Respir Crit Care Med"},{"key":"2026031105265509100_bib19","doi-asserted-by":"crossref","first-page":"2059","DOI":"10.1097\/CCM.0b013e31821e8779","article-title":"Dyspnea in mechanically ventilated critically ill patients","volume":"39","author":"Schmidt","year":"2011","journal-title":"Crit Care Med"},{"key":"2026031105265509100_bib20","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.resp.2007.01.006","article-title":"Verbal numerical scales are as reliable and sensitive as visual analog scales for rating dyspnea in young and older subjects","volume":"157","author":"Morris","year":"2007","journal-title":"Respir Physiol Neurobiol"},{"key":"2026031105265509100_bib21","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1152\/jappl.1993.74.4.1475","article-title":"Airway occlusion pressure","volume":"74","author":"Whitelaw","year":"1993","journal-title":"J Appl Physiol (1985)"},{"key":"2026031105265509100_bib22","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1164\/rccm.201907-1425OC","article-title":"Airway occlusion pressure as an estimate of respiratory drive and inspiratory effort during assisted ventilation","volume":"201","author":"Telias","year":"2020","journal-title":"Am J Respir Crit Care Med"},{"key":"2026031105265509100_bib23","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1186\/s13613-019-0576-x","article-title":"Accuracy of P0.1 measurements performed by ICU ventilators: a bench study","volume":"9","author":"Beloncle","year":"2019","journal-title":"Ann Intensive Care"},{"key":"2026031105265509100_bib24","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1007\/s00134-013-2910-3","article-title":"Dyspnea and surface inspiratory electromyograms in mechanically ventilated patients","volume":"39","author":"Schmidt","year":"2013","journal-title":"Intensive Care Med"},{"key":"2026031105265509100_bib25","first-page":"788","article-title":"A simple method for assessing the validity of the esophageal balloon technique","volume":"126","author":"Baydur","year":"1982","journal-title":"Am Rev Respir Dis"},{"key":"2026031105265509100_bib26","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.4187\/respcare.09085","article-title":"Hygrometric performances of different high-flow nasal cannula devices: bench evaluation and clinical tolerance","volume":"66","author":"Delorme","year":"2021","journal-title":"Respir Care"},{"key":"2026031105265509100_bib27","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.resp.2005.04.008","article-title":"Optimized analysis of surface electromyograms of the scalenes during quiet breathing in humans","volume":"150","author":"Hug","year":"2006","journal-title":"Respir Physiol Neurobiol"},{"key":"2026031105265509100_bib28","doi-asserted-by":"crossref","first-page":"1800598","DOI":"10.1183\/13993003.00598-2018","article-title":"The Mechanical Ventilation\u2013Respiratory Distress Observation Scale as a surrogate of self-reported dyspnoea in intubated patients","volume":"52","author":"Decav\u00e8le","year":"2018","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib29","doi-asserted-by":"crossref","first-page":"1902202","DOI":"10.1183\/13993003.02202-2019","article-title":"Minimal clinically important differences in average, best, worst and current intensity and unpleasantness of chronic breathlessness","volume":"56","author":"Ekstr\u00f6m","year":"2020","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib30","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1164\/rccm.202108-1857OC","article-title":"Prevalence, intensity, and clinical impact of dyspnea in critically ill patients receiving invasive ventilation","volume":"205","author":"Demoule","year":"2022","journal-title":"Am J Respir Crit Care Med"},{"key":"2026031105265509100_bib31","doi-asserted-by":"crossref","first-page":"2238","DOI":"10.1007\/s00134-020-06228-7","article-title":"Use of nasal high flow oxygen during acute respiratory failure","volume":"46","author":"Ricard","year":"2020","journal-title":"Intensive Care Med"},{"key":"2026031105265509100_bib32","doi-asserted-by":"crossref","first-page":"485","DOI":"10.4187\/respcare.02397","article-title":"High-flow nasal cannula versus conventional oxygen therapy after endotracheal extubation: a randomized crossover physiologic study","volume":"59","author":"Rittayamai","year":"2014","journal-title":"Respir Care"},{"key":"2026031105265509100_bib33","doi-asserted-by":"crossref","first-page":"2400485","DOI":"10.1183\/13993003.00485-2024","article-title":"Medical hypnosis mitigates laboratory dyspnoea in healthy humans: a randomised, controlled experimental trial","volume":"64","author":"Mor\u00e9lot-Panzini","year":"2024","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib34","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.ahj.2012.05.003","article-title":"Minimally clinically important difference in chronic breathlessness: every little helps","volume":"164","author":"Oxberry","year":"2012","journal-title":"Am Heart J"},{"key":"2026031105265509100_bib35","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1081\/COPD-200050655","article-title":"Minimally clinically important difference for the UCSD Shortness of Breath Questionnaire, Borg Scale, and Visual Analog Scale","volume":"2","author":"Ries","year":"2005","journal-title":"COPD"},{"key":"2026031105265509100_bib36","doi-asserted-by":"crossref","first-page":"1902107","DOI":"10.1183\/13993003.02107-2019","article-title":"Association of dyspnoea, mortality and resource use in hospitalised patients","volume":"58","author":"Stevens","year":"2021","journal-title":"Eur Respir J"},{"key":"2026031105265509100_bib37","doi-asserted-by":"crossref","first-page":"104035","DOI":"10.1016\/j.resp.2023.104035","article-title":"Impact of trigeminal and\/or olfactory nerve stimulation on measures of inspiratory neural drive: implications for breathlessness","volume":"311","author":"Aucoin","year":"2023","journal-title":"Respir Physiol Neurobiol"},{"key":"2026031105265509100_bib38","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1016\/S0092-8674(02)00652-9","article-title":"A TRP channel that senses cold stimuli and menthol","volume":"108","author":"Peier","year":"2002","journal-title":"Cell"},{"key":"2026031105265509100_bib39","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1152\/jn.00843.2002","article-title":"TRPM8 mRNA is expressed in a subset of cold-responsive trigeminal neurons from rat","volume":"90","author":"Nealen","year":"2003","journal-title":"J Neurophysiol"},{"key":"2026031105265509100_bib40","doi-asserted-by":"crossref","first-page":"104036","DOI":"10.1016\/j.resp.2023.104036","article-title":"Impact of trigeminal nerve and\/or olfactory nerve stimulation on activity of human brain regions involved in the perception of breathlessness","volume":"311","author":"Aucoin","year":"2023","journal-title":"Respir Physiol Neurobiol"},{"key":"2026031105265509100_bib41","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1164\/ajrccm.156.1.9609059","article-title":"Nasal inhalation of l-menthol reduces respiratory discomfort associated with loaded breathing","volume":"156","author":"Nishino","year":"1997","journal-title":"Am J Respir Crit Care Med"},{"key":"2026031105265509100_bib42","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1038\/nn1856","article-title":"Dual functions of mammalian olfactory sensory neurons as odor detectors and mechanical sensors","volume":"10","author":"Grosmaitre","year":"2007","journal-title":"Nat Neurosci"},{"key":"2026031105265509100_bib43","doi-asserted-by":"crossref","first-page":"12448","DOI":"10.1523\/JNEUROSCI.2586-16.2016","article-title":"Nasal respiration entrains human limbic oscillations and modulates cognitive function","volume":"36","author":"Zelano","year":"2016","journal-title":"J Neurosci"},{"key":"2026031105265509100_bib44","doi-asserted-by":"crossref","first-page":"645","DOI":"10.3390\/healthcare9060645","article-title":"Investigation on the effect of oral breathing on cognitive activity using functional brain imaging","volume":"9","author":"Jung","year":"2021","journal-title":"Healthcare"}],"container-title":["American Journal of Respiratory and Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/211\/4\/577\/67294525\/ajrccm_211_4_577.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ajrccm\/article-pdf\/211\/4\/577\/67294525\/ajrccm_211_4_577.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T09:27:08Z","timestamp":1773221228000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ajrccm\/article\/211\/4\/577\/8513462"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,1]]},"references-count":44,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4,1]]},"published-print":{"date-parts":[[2025,4,1]]}},"URL":"https:\/\/doi.org\/10.1164\/rccm.202405-1057oc","relation":{},"ISSN":["1073-449X","1535-4970"],"issn-type":[{"value":"1073-449X","type":"print"},{"value":"1535-4970","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,4]]},"published":{"date-parts":[[2025,4,1]]},"assertion":[{"value":"2024-05-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-12-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}