{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T03:53:22Z","timestamp":1773978802444,"version":"3.50.1"},"reference-count":30,"publisher":"American Scientific Publishers","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["j nanosci nanotechnol"],"published-print":{"date-parts":[[2021,5,1]]},"abstract":"<jats:p>The fabrication of a network of glucose oxidase-horseradish peroxidase\/tin oxide (GOx-HRP\/SnO<jats:sub>2<\/jats:sub>), immobilized onto a glassy carbon electrode (GCE) and its utilization as a biosensor for glucose detection is reported. The network established with GOx-HRP\/SnO<jats:sub>2<\/jats:sub> possess\n high sensitivity and stability by performing the electrocatalytic features in the sensing of glucose. The turbidity of fabrication had been scanned and analyzed using UV-vis spectroscopy. The morphology and composition of the fabricated GOx-HRP\/SnO<jats:sub>2<\/jats:sub> networks were characterized by\n scanning electron microscopy (SEM). Cyclic voltammetry and amperometry were employed to study the electrochemical properties of the proposed biosensor. The effect of applied electrode potential and pH were systemically investigated. The biosensor responds to glucose at work potential values\n between \u2212400 mV, and exhibited a lower detection limit (0.025 mM) and long linear range (0.25 to 7.0 mM), and was resistant to common interferences.<\/jats:p>","DOI":"10.1166\/jnn.2021.19283","type":"journal-article","created":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T12:11:12Z","timestamp":1614773472000},"page":"3059-3064","source":"Crossref","is-referenced-by-count":8,"title":["Glucose Biosensor Based on Glucose Oxidase-Horseradish Peroxidase\/Multiporous Tin Oxide (SnO<sub>2<\/sub>) Modified Electrode"],"prefix":"10.1166","volume":"21","author":[{"given":"A. K. M.","family":"Kafi","sequence":"first","affiliation":[{"name":"Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aizam","family":"Bin Kasri","sequence":"additional","affiliation":[{"name":"Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajan","family":"Jose","sequence":"additional","affiliation":[{"name":"Faculty of Industrial Sciences & Technology, Universiti Malaysia Pahang, Kuantan 26300, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"17","reference":[{"issue":"(2)","key":"r1","doi-asserted-by":"crossref","first-page":"pp.814","DOI":"10.1021\/cr068123a","article-title":"Electrochemical glucose biosensors.","volume":"108","author":"Wang","year":"2008","journal-title":"Chemical Reviews"},{"issue":"(8)","key":"r2","doi-asserted-by":"crossref","first-page":"pp.1278","DOI":"10.1016\/j.bios.2007.11.010","article-title":"Use of hydrogel coating to improve the performance of implanted glucose sensors.","volume":"23","author":"Yu","year":"2008","journal-title":"Biosensors and Bioelectron-ics"},{"issue":"(12)","key":"r3","doi-asserted-by":"crossref","first-page":"pp.2435","DOI":"10.1016\/j.bios.2004.11.012","article-title":"Home blood glucose biosensors: A commercial perspective.","volume":"20","author":"Newman","year":"2005","journal-title":"Biosensors and Bioelectron-ics"},{"key":"r4","doi-asserted-by":"crossref","first-page":"pp.40","DOI":"10.1016\/j.enzmictec.2015.06.006","article-title":"Glucose biosensor based on glucose oxidase immobilized at gold nanoparticles decorated graphene-carbon nanotubes.","volume":"78","author":"Devasenathipathy","year":"2015","journal-title":"Enzyme Microb. Technol."},{"key":"r5","doi-asserted-by":"crossref","first-page":"pp.96","DOI":"10.1016\/j.talanta.2013.02.022","article-title":"Bienzymatic glucose biosensor based on direct electrochemistry of cytochrome c on gold nanoparticles\/polyaniline nanospheres composite.","volume":"110","author":"Xiang","year":"2013","journal-title":"Talanta"},{"key":"r6","doi-asserted-by":"crossref","first-page":"pp.165","DOI":"10.1016\/j.cej.2014.11.011","article-title":"Biofuel cell based on glucose oxidase from Penicillium funiculosum 46.1 and horseradish peroxidase.","volume":"264","author":"Ramanavicius","year":"2015","journal-title":"Chemical Engineering Journal"},{"key":"r7","doi-asserted-by":"crossref","first-page":"pp.1039","DOI":"10.1021\/acsami.7b13835","article-title":"Mesoporous iron oxide synthesized using poly(styrene-b-acrylic acid-b-ethylene gly-col) block copolymer micelles as templates for colorimetric and electrochemical detection of glucose.","volume":"10","author":"Tanaka","year":"2018","journal-title":"ACS Applied Materials & Interfaces"},{"key":"r8","doi-asserted-by":"crossref","first-page":"pp.83","DOI":"10.1016\/j.aca.2015.01.027","article-title":"Direct electron transfer of glucose oxidase and dual hydrogen peroxide and glucose detection based on water-dispersible carbon nanotubes derivative.","volume":"867","author":"Chen","year":"2015","journal-title":"Analytica Chimica Acta"},{"issue":"(11)","key":"r9","doi-asserted-by":"crossref","first-page":"pp.2002","DOI":"10.1373\/clinchem.2007.090795","article-title":"Applications of nanobiotechnology in clinical diagnostics.","volume":"53","author":"Jain","year":"2007","journal-title":"Clinical Chemistry"},{"key":"r10","doi-asserted-by":"crossref","first-page":"pp.34544","DOI":"10.1021\/acsami.7b07063","article-title":"Flexible graphene-based wearable gas and chemical sensors.","volume":"9","author":"Singh","year":"2017","journal-title":"ACS Applied Materials & Interfaces"},{"key":"r11","doi-asserted-by":"crossref","first-page":"pp.8778","DOI":"10.1039\/C8RA09577A","article-title":"A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.","volume":"9","author":"Krishnan","year":"2019","journal-title":"RSC Advances"},{"key":"r12","first-page":"pp.427","article-title":"Nanoparticles in molecular diagnostics. in","volume-title":"Progress in Molecular Biology and Translational Science","volume":"Vol. 104","author":"Baptista","year":"2011"},{"key":"r13","doi-asserted-by":"crossref","first-page":"pp.1039","DOI":"10.1016\/j.jpowsour.2015.06.037","article-title":"Tin oxide as a pho-toanode for dye-sensitised solar cells: Current progress and future challenges.","volume":"293","author":"Wali","year":"2015","journal-title":"Journal of Power Sources"},{"key":"r14","doi-asserted-by":"crossref","first-page":"pp.3066","DOI":"10.1039\/C4TA05923A","article-title":"Enhancing the performance of dye-sensitized solar cells: Doping SnO2 photoanodes with Al to simultaneously improve conduction band and electron lifetime.","volume":"3","author":"Duan","year":"2015","journal-title":"Journal of Materials Chemistry A"},{"key":"r15","doi-asserted-by":"crossref","first-page":"pp.366","DOI":"10.1016\/j.electacta.2014.09.098","article-title":"TiO2 compact layer for dye-sensitized SnO2 nanocrystalline thin film.","volume":"147","author":"Yang","year":"2014","journal-title":"Electrochimica Acta"},{"issue":"(2)","key":"r16","first-page":"pp.023120","article-title":"Nanoporous tin oxide photoelectrode prepared by electrochemical anodization in aqueous ammonia to improve performance of dye sensitized solar cell.","volume":"5","author":"Teh","year":"2013","journal-title":"Journal of Renewable and Sustainable Energy"},{"issue":"(11)","key":"r17","doi-asserted-by":"crossref","first-page":"pp.4135","DOI":"10.1016\/j.electacta.2011.01.110","article-title":"The interconnected CaCO3 coated SnO2 nanocrystalline dye-sensitized solar cell with superior performance.","volume":"56","author":"Perera","year":"2011","journal-title":"Electrochimica Acta"},{"issue":"(30)","key":"r18","doi-asserted-by":"crossref","first-page":"pp.16856","DOI":"10.1021\/jp500364v","article-title":"Porous tin oxide nanosheets with enhanced conversion efficiency as dye-sensitized solar cell electrode.","volume":"118","author":"Xu","year":"2014","journal-title":"Journal of Physical Chemistry C"},{"issue":"(7)","key":"r19","doi-asserted-by":"crossref","first-page":"pp.2061","DOI":"10.1039\/c3an36754a","article-title":"Fabrication of Cr doped SnO2 nanoparticles based biosensor for the selective determination of riboflavin in pharmaceuticals.","volume":"138","author":"Lavanya","year":"2013","journal-title":"Analyst"},{"issue":"(6)","key":"r20","doi-asserted-by":"crossref","first-page":"pp.617","DOI":"10.1166\/jno.2017.2062","article-title":"High sensitivity and recoverable SnO2-based sensor promoted with Fe2O3 and ZnO for sub-ppm H2S detection.","volume":"12","author":"Hwang","year":"2017","journal-title":"Journal of Nanoelectronics and Optoelectronics"},{"key":"r21","first-page":"pp.1","article-title":"Pd-doped SnO2-based sensor detecting characteristic fault hydrocarbon gases in transformer oil.","volume":"2013","author":"Chen","year":"2013","journal-title":"Journal of Nanomaterials"},{"key":"r22","first-page":"pp.40","article-title":"Sensitivity and selectivity of SnO2-based sensor for CO and H2 detections: A novel method to detect simultaneously the CO and H2 concentrations. in","volume-title":"Advances in Science and Technology","volume":"Vol. 99","author":"Guo","year":"2017"},{"issue":"(1)","key":"r23","doi-asserted-by":"crossref","first-page":"pp.10301","DOI":"10.1051\/epjap\/2015150161","article-title":"Enhanced sensing properties of ZnO-SnO2 based composite type gas sensor.","volume":"73","author":"Mondal","year":"2016","journal-title":"European Physical Journal Applied Physics"},{"key":"r24","first-page":"pp.1","article-title":"Sensing Properties of NiO@SnO2 Based Sensor to Hydrogen Extracted from Transformer Oil.","author":"Wei","year":"2016","journal-title":"2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE)"},{"issue":"(2)","key":"r25","doi-asserted-by":"crossref","first-page":"pp.955","DOI":"10.1016\/j.cej.2011.02.029","article-title":"Fast synthesis optical and bio-sensor properties of SnO2 nanostructures by electrochemical deposition.","volume":"168","author":"Chu","year":"2011","journal-title":"Chemical Engineering Journal"},{"issue":"(11)","key":"r26","doi-asserted-by":"crossref","first-page":"pp.4443","DOI":"10.1007\/s00604-017-2479-6","article-title":"A glassy carbon electrode modified with SnO2 nanofibers, polyaniline and hemoglobin for improved amperometric sensing of hydrogen peroxide.","volume":"184","author":"Kafi","year":"2017","journal-title":"Microchimica Acta"},{"issue":"(2)","key":"r27","doi-asserted-by":"crossref","first-page":"pp.183","DOI":"10.1016\/j.jcis.2009.02.043","article-title":"Zinc oxide nanoparticles\/glucose oxidase photo-electrochemical system for the fabrication of biosensor.","volume":"334","author":"Ren","year":"2009","journal-title":"Journal of Colloid and Interface Science"},{"key":"r28","doi-asserted-by":"crossref","first-page":"pp.8","DOI":"10.1016\/j.bios.2018.02.061","article-title":"Glucose biosensor based on disposable electrochemical paper-based transducers fully fabricated by screen-printing.","volume":"109","author":"Lamas-Ardisana","year":"2018","journal-title":"Biosensors and Bioelectronics"},{"key":"r29","doi-asserted-by":"crossref","first-page":"pp.164","DOI":"10.1016\/j.colsurfb.2013.10.006","article-title":"Direct electrochemistry and electrocatalysis of glucose oxidase immobilized on reduced graphene oxide and silver nanoparticles nanocomposite modified electrode.","volume":"114","author":"Palanisamy","year":"2014","journal-title":"Colloids and Surfaces B: Biointerfaces"},{"key":"r30","doi-asserted-by":"crossref","first-page":"pp.204","DOI":"10.1016\/j.talanta.2017.04.047","article-title":"Reagent-less amperometric glucose biosensor based on a graphite rod electrode layer-by-layer modified with 1,10-phenanthroline-5,6-dione and glucose oxidase.","volume":"171","author":"Kausaite-Minkstimiene","year":"2017","journal-title":"Talanta"}],"container-title":["Journal of Nanoscience and Nanotechnology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ingentaconnect.com\/content\/asp\/jnn\/2021\/00000021\/00000005\/art00042","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T12:27:18Z","timestamp":1614774438000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ingentaconnect.com\/content\/10.1166\/jnn.2021.19283"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,1]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,5,1]]}},"alternative-id":["1533-4880(20210501)21:5L.3059;1-"],"URL":"https:\/\/doi.org\/10.1166\/jnn.2021.19283","relation":{},"ISSN":["1533-4880"],"issn-type":[{"value":"1533-4880","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5,1]]}}}