{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:59:35Z","timestamp":1791928775562,"version":"4.3.4"},"reference-count":34,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"8","license":[{"start":{"date-parts":[[2022,7,12]],"date-time":"2022-07-12T00:00:00Z","timestamp":1657584000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest. Ophthalmol. Vis. Sci."],"published-print":{"date-parts":[[2022,7,12]]},"DOI":"10.1167\/iovs.63.8.10","type":"journal-article","created":{"date-parts":[[2022,7,12]],"date-time":"2022-07-12T09:31:32Z","timestamp":1657618292000},"page":"10","source":"Crossref","is-referenced-by-count":18,"title":["Peripheral Refraction With Toric Orthokeratology and Soft Toric Multifocal Contact Lenses in Myopic Astigmatic Eyes"],"prefix":"10.1167","volume":"63","author":[{"given":"Erin S.","family":"Tomiyama","sequence":"first","affiliation":[{"name":"University of Houston College of Optometry, Houston, Texas, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David A.","family":"Berntsen","sequence":"additional","affiliation":[{"name":"University of Houston College of Optometry, Houston, Texas, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathryn","family":"Richdale","sequence":"additional","affiliation":[{"name":"University of Houston College of Optometry, Houston, Texas, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"issue":"1","key":"bib1","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/ICL.0b013e3182048fb9","article-title":"Prevalence of Astigmatism in Relation to Soft Contact Lens Fitting","volume":"37","author":"Young","year":"2011","journal-title":"Eye Contact Lens"},{"issue":"8","key":"bib2","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1001\/archopht.121.8.1141","article-title":"Refractive Error and Ethnicity in Children","volume":"121","author":"Kleinstein","year":"2003","journal-title":"Arch Ophthalmol"},{"issue":"6","key":"bib3","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1136\/bjophthalmol-2018-312114","article-title":"Astigmatism and its components in 12-year-old Chinese children: the Anyang Childhood Eye Study","volume":"103","author":"Li","year":"2019","journal-title":"Br J Ophthalmol"},{"issue":"3","key":"bib4","doi-asserted-by":"publisher","first-page":"M132","DOI":"10.1167\/iovs.18-25955","article-title":"IMI \u2013 Clinical Myopia Control Trials and Instrumentation Report","volume":"60","author":"Wolffsohn","year":"2019","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"10","key":"bib5","doi-asserted-by":"publisher","first-page":"6510","DOI":"10.1167\/iovs.13-12527","article-title":"Myopia Control Using Toric Orthokeratology (TO-SEE Study)","volume":"54","author":"Chen","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"5","key":"bib6","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1111\/j.1444-0938.2002.tb03084.x","article-title":"An analysis of the astigmatic changes induced by accelerated orthokeratology","volume":"85","author":"Mountford","year":"2002","journal-title":"Clin Exp Optometry"},{"issue":"12","key":"bib7","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.1097\/OPX.0b013e3181be06ff","article-title":"Astigmatic Changes in Orthokeratology","volume":"86","author":"Cheung","year":"2009","journal-title":"Optometry Vis Sci"},{"issue":"2","key":"bib8","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1076\/ceyr.28.2.121.26236","article-title":"Subjective and objective assessments of the effect of orthokeratology \u2013 A cross-sectional study","volume":"28","author":"Cheung","year":"2004","journal-title":"Curr Eye Res"},{"issue":"3","key":"bib9","doi-asserted-by":"publisher","first-page":"M31","DOI":"10.1167\/iovs.18-25967","article-title":"IMI \u2013 Report on Experimental Models of Emmetropization and Myopia","volume":"60","author":"Troilo","year":"2019","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"3","key":"bib10","doi-asserted-by":"publisher","first-page":"M106","DOI":"10.1167\/iovs.18-25958","article-title":"IMI \u2013 Interventions for Controlling Myopia Onset and Progression Report","volume":"60","author":"Wildsoet","year":"2019","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"8","key":"bib11","doi-asserted-by":"publisher","first-page":"5761","DOI":"10.1167\/iovs.13-11904","article-title":"Peripheral Defocus and Myopia Progression in Myopic Children Randomly Assigned to Wear Single Vision and Progressive Addition Lenses","volume":"54","author":"Berntsen","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"bib12","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1111\/opo.v41.4","article-title":"Greater higher order aberrations induced by toric orthokeratology versus soft toric multifocal contact lens wear","volume":"41","author":"Tomiyama","year":"2021","journal-title":"Ophthalmic Physiological Optics"},{"issue":"2","key":"bib13","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1097\/ICL.0000000000000721","article-title":"Corneal Elevation, Power, and Astigmatism to Assess Toric Orthokeratology Lenses in Moderate-to-High Astigmats","volume":"47","author":"Tomiyama","year":"2021","journal-title":"Eye Contact Lens: Sci Clin Pract"},{"issue":"6","key":"bib14","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1001\/jama.2020.10834","article-title":"Effect of High Add Power, Medium Add Power, or Single-Vision Contact Lenses on Myopia Progression in Children","volume":"324","author":"Walline","year":"2020","journal-title":"JAMA"},{"issue":"9","key":"bib15","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1097\/OPX.0000000000000889","article-title":"The Influence of Different OK Lens Designs on Peripheral Refraction","volume":"93","author":"Kang","year":"2016","journal-title":"Optometry Vis Sci"},{"issue":"12","key":"bib16","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1097\/00006324-199312000-00005","article-title":"Comparison of Cyclopentolate Versus Tropicamide Cycloplegia in Children","volume":"70","author":"Egashira","year":"1993","journal-title":"Optometry Vis Sci"},{"issue":"9","key":"bib17","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.1097\/OPX.0000000000000351","article-title":"Central and Peripheral Autorefraction Repeatability in Normal Eyes","volume":"91","author":"Moore","year":"2014","journal-title":"Optometry Vis Sci"},{"issue":"9","key":"bib18","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1097\/OPX.0b013e3181ea16ea","article-title":"Peripheral Refraction With and Without Contact Lens Correction","volume":"87","author":"Shen","year":"2010","journal-title":"Optometry Vis Sci"},{"issue":"4","key":"bib19","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1111\/j.1475-1313.2012.00912.x","article-title":"Peripheral refraction in myopia corrected with spectacles versus contact lenses","volume":"32","author":"Backhouse","year":"2012","journal-title":"Ophthalmic Physiolog Optics"},{"issue":"9","key":"bib20","doi-asserted-by":"publisher","first-page":"856","DOI":"10.1097\/OPX.0000000000001106","article-title":"A Randomized Trial of Soft Multifocal Contact Lenses for Myopia Control","volume":"94","author":"Walline","year":"2017","journal-title":"Optometry Vis Sci"},{"issue":"7","key":"bib21","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1097\/OPX.0000000000001540","article-title":"Randomized Clinical Trial of Near Visual Performance with Digital Devices Using Spherical and Toric Contact Lenses","volume":"97","author":"Logan","year":"2020","journal-title":"Optometry Vis Sci"},{"issue":"1","key":"bib22","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1097\/ICL.0000000000000203","article-title":"Success rate of incorporating corneal refractive therapy into 3 different ophthalmology practices","volume":"42","author":"Koffler","year":"2016","journal-title":"Eye Contact Lens"},{"issue":"5","key":"bib23","doi-asserted-by":"publisher","first-page":"S624","DOI":"10.3928\/1081-597X-20040901-41","article-title":"Alcon CustomCornea wavefront-guided retreatments after laser in situ keratomileusis","volume":"20","author":"Chalita","year":"2004","journal-title":"J Refract Surg"},{"issue":"5","key":"bib25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/OPX.0b013e3181d951f7","article-title":"Peripheral Refraction in Myopic Patients After Orthokeratology","volume":"87","author":"Queir\u00f3s","year":"2010","journal-title":"Optometry Vis Sci"},{"issue":"4","key":"bib26","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1097\/OPX.0b013e31820f16fb","article-title":"Peripheral refraction in myopic children wearing orthokeratology and gas-permeable lenses","volume":"88","author":"Kang","year":"2011","journal-title":"Optometry Vis Sci"},{"issue":"3","key":"bib27","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1111\/opo.12027","article-title":"Time course of the effects of orthokeratology on peripheral refraction and corneal topography","volume":"33","author":"Kang","year":"2013","journal-title":"Ophthalmic Physiolog Optics"},{"issue":"5","key":"bib28","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1097\/OPX.0000000000000826","article-title":"New Perspective on Myopia Control with Orthokeratology","volume":"93","author":"Kang","year":"2016","journal-title":"Optometry Vis Sci"},{"issue":"1","key":"bib29","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.clae.2019.11.006","article-title":"Reducing treatment zone diameter in orthokeratology and its effect on peripheral ocular refraction","volume":"43","author":"Gifford","year":"2020","journal-title":"Contact Lens Anterior Eye"},{"issue":"1","key":"bib30","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1097\/OPX.0b013e3182781868","article-title":"Peripheral Optics with Bifocal Soft and Corneal Reshaping Contact Lenses","volume":"90","author":"Ticak","year":"2013","journal-title":"Optometry Vis Sci"},{"issue":"11","key":"bib31","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1097\/OPX.0000000000000066","article-title":"Peripheral Defocus with Spherical and Multifocal Soft Contact Lenses","volume":"90","author":"Berntsen","year":"2013","journal-title":"Optometry Vis Sci"},{"issue":"7","key":"bib32","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1097\/OPX.0b013e3182990878","article-title":"The effect of multifocal soft contact lenses on peripheral refraction","volume":"90","author":"Kang","year":"2013","journal-title":"Optometry Vis Sci"},{"issue":"2","key":"bib33","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.optom.2013.01.001","article-title":"Peripheral refraction with dominant design multifocal contact lenses in young myopes","volume":"6","author":"Lopes-Ferreira","year":"2013","journal-title":"J Optometry"},{"issue":"1","key":"bib34","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1186\/s12886-016-0302-5","article-title":"Effects of orthokeratology on the progression of low to moderate myopia in Chinese children","volume":"16","author":"He","year":"2016","journal-title":"BMC Ophthalmol"},{"key":"bib24","author":"Euclid Systems Corporation"}],"container-title":["Investigative Opthalmology &amp; Visual Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/iovs.arvojournals.org\/article.aspx?articleid=2783468","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:31:30Z","timestamp":1791927090000},"score":1,"resource":{"primary":{"URL":"https:\/\/iovs.arvojournals.org\/article.aspx?articleid=2783468"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,12]]},"references-count":34,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2022,7,8]]}},"URL":"https:\/\/doi.org\/10.1167\/iovs.63.8.10","relation":{},"ISSN":["1552-5783"],"issn-type":[{"value":"1552-5783","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7,12]]}}}