{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T22:00:51Z","timestamp":1791928851115,"version":"4.3.4"},"reference-count":38,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"6","license":[{"start":{"date-parts":[[2024,6,5]],"date-time":"2024-06-05T00:00:00Z","timestamp":1717545600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest. Ophthalmol. Vis. Sci."],"published-print":{"date-parts":[[2024,6,5]]},"DOI":"10.1167\/iovs.65.6.9","type":"journal-article","created":{"date-parts":[[2024,6,5]],"date-time":"2024-06-05T12:28:11Z","timestamp":1717590491000},"page":"9","source":"Crossref","is-referenced-by-count":7,"title":["Time-Resolved Dynamic Optical Coherence Tomography for Retinal Blood Flow Analysis"],"prefix":"10.1167","volume":"65","author":[{"given":"Philippe","family":"Valmaggia","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland"},{"name":"Institute of Molecular and Clinical Ophthalmology Basel (IOB), Basel, Basel, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe C.","family":"Cattin","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin","family":"Sandk\u00fchler","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nadja","family":"Inglin","sequence":"additional","affiliation":[{"name":"Institute of Molecular and Clinical Ophthalmology Basel (IOB), Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tilman P.","family":"Otto","sequence":"additional","affiliation":[{"name":"Heidelberg Engineering GmbH, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silke","family":"Aumann","sequence":"additional","affiliation":[{"name":"Heidelberg Engineering GmbH, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel M.","family":"Teussink","sequence":"additional","affiliation":[{"name":"Heidelberg Engineering GmbH, Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard F.","family":"Spaide","sequence":"additional","affiliation":[{"name":"Vitreous Retina Macula Consultants of New York, New York, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hendrik P. N.","family":"Scholl","sequence":"additional","affiliation":[{"name":"Institute of Molecular and Clinical Ophthalmology Basel (IOB), Basel, Basel, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter M.","family":"Maloca","sequence":"additional","affiliation":[{"name":"Institute of Molecular and Clinical Ophthalmology Basel (IOB), Basel, Basel, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"issue":"5035","key":"bib1","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1126\/science.1957169","article-title":"Optical coherence tomography","volume":"254","author":"Huang","year":"1991","journal-title":"Science"},{"issue":"5","key":"bib2","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1364\/OL.22.000340","article-title":"Optical coherence tomography using a frequency-tunable optical source","volume":"22","author":"Chinn","year":"1997","journal-title":"Opt Lett"},{"issue":"9","key":"bib3","doi-asserted-by":"publisher","first-page":"OCT1","DOI":"10.1167\/iovs.16-19963","article-title":"The development, commercialization, and impact of optical coherence tomography","volume":"57","author":"Fujimoto","year":"2016","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","article-title":"Optical coherence tomography angiography","volume":"64","author":"Spaide","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.preteyeres.2014.03.004","article-title":"Doppler optical coherence tomography","volume":"41","author":"Leitgeb","year":"2014","journal-title":"Prog Retin Eye Res"},{"issue":"3","key":"bib6","doi-asserted-by":"publisher","first-page":"220","DOI":"10.3390\/photonics1030220","article-title":"Basic technology and clinical applications of the updated model of laser speckle flowgraphy to ocular diseases","volume":"1","author":"Sugiyama","year":"2014","journal-title":"Photonics"},{"issue":"3","key":"bib7","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1080\/02713683.2017.1414853","article-title":"A mini review of clinical and research applications of the retinal function imager","volume":"43","author":"Wang","year":"2018","journal-title":"Curr Eye Res"},{"issue":"25","key":"bib9","doi-asserted-by":"publisher","first-page":"3490","DOI":"10.1364\/OE.11.003490","article-title":"In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical Doppler tomography","volume":"11","author":"White","year":"2003","journal-title":"Opt Express"},{"issue":"6","key":"bib10","doi-asserted-by":"publisher","first-page":"1539","DOI":"10.1364\/BOE.2.001539","article-title":"Total retinal blood flow measurement with ultrahigh speed swept source\/Fourier domain OCT","volume":"2","author":"Baumann","year":"2011","journal-title":"Biomed Opt Express"},{"issue":"10","key":"bib11","doi-asserted-by":"publisher","first-page":"6062","DOI":"10.1167\/iovs.12-9514","article-title":"Measurement of absolute blood flow velocity and blood flow in the human retina by dual-beam bidirectional Doppler fourier-domain optical coherence tomography","volume":"53","author":"Werkmeister","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"bib12","first-page":"1","article-title":"Investigating spontaneous retinal venous pulsation using Doppler optical coherence tomography","volume":"9","author":"Wartak","year":"2019","journal-title":"Sci Reports"},{"issue":"12","key":"bib13","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1080\/17434440.2018.1548932","article-title":"Optical coherence tomography angiography (OCTA) flow speed mapping technology for retinal diseases","volume":"15","author":"Arya","year":"2018","journal-title":"Expert Rev Med Devices"},{"issue":"1","key":"bib14","doi-asserted-by":"publisher","first-page":"3695","DOI":"10.1038\/s41598-022-07439-2","article-title":"Reference database of total retinal vessel surface area derived from volume-rendered optical coherence tomography angiography","volume":"12","author":"Maloca","year":"2022","journal-title":"Sci Rep"},{"issue":"4","key":"bib15","doi-asserted-by":"publisher","first-page":"1205","DOI":"10.1109\/2944.796348","article-title":"Optical coherence tomography (OCT): a review","volume":"5","author":"Schmitt","year":"1999","journal-title":"IEEE J Sel Top Quantum Electron"},{"issue":"Suppl 6","key":"bib17","first-page":"6","article-title":"Spectral domain optical coherence tomography: a better OCT imaging strategy","volume":"39","author":"Yaqoob","year":"2005","journal-title":"Biotechniques"},{"issue":"13","key":"bib18","doi-asserted-by":"publisher","first-page":"2977","DOI":"10.1364\/OPEX.12.002977","article-title":"Motion artifacts in optical coherence tomography with frequency-domain ranging","volume":"12","author":"Yun","year":"2004","journal-title":"Opt Express"},{"issue":"4","key":"bib19","doi-asserted-by":"publisher","first-page":"041511","DOI":"10.1117\/1.3466578","article-title":"Signal power decrease due to fringe washout as an extension of the limited Doppler flow measurement range in spectral domain optical coherence tomography","volume":"15","author":"Walther","year":"2010","journal-title":"J Biomed Opt"},{"issue":"8","key":"bib20","doi-asserted-by":"publisher","first-page":"9757","DOI":"10.1364\/OE.21.009757","article-title":"Averaging techniques for OCT imaging","volume":"21","author":"Szkulmowski","year":"2013","journal-title":"Opt Express"},{"issue":"8","key":"bib21","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1097\/IAE.0000000000003474","article-title":"Imaging the vitreous with a novel boosted optical coherence tomography technique: vitreous degeneration and cisterns","volume":"42","author":"Spaide","year":"2022","journal-title":"Retina"},{"issue":"7","key":"bib22","doi-asserted-by":"publisher","first-page":"3248","DOI":"10.1364\/BOE.8.003248","article-title":"Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited]","volume":"8","author":"De Boer","year":"2017","journal-title":"Biomed Opt Express"},{"issue":"18","key":"bib23","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.1364\/OE.11.002183","article-title":"Sensitivity advantage of swept source and Fourier domain optical coherence tomography","volume":"11","author":"Choma","year":"2003","journal-title":"Opt Express"},{"issue":"1","key":"bib24","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1109\/83.650848","article-title":"A pyramid approach to subpixel registration based on intensity","volume":"7","author":"Th\u00e9venaz","year":"1998","journal-title":"IEEE Trans Image Process"},{"issue":"1","key":"bib25","doi-asserted-by":"publisher","first-page":"570","DOI":"10.32614\/RJ-2021-053","article-title":"Reproducible summary tables with the gtsummary package","volume":"13","author":"Sjoberg","year":"2021","journal-title":"R Journal"},{"issue":"9","key":"bib26","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","article-title":"3D Slicer as an image computing platform for the Quantitative Imaging Network","volume":"30","author":"Fedorov","year":"2012","journal-title":"Magn Reson Imaging"},{"issue":"4","key":"bib27","doi-asserted-by":"publisher","first-page":"041208","DOI":"10.1117\/1.2772879","article-title":"Enhancing the signal-to-noise ratio in ophthalmic optical coherence tomography by image registration\u2014method and clinical examples","volume":"12","author":"Jo?rgensen","year":"2007","journal-title":"J Biomed Opt"},{"issue":"8","key":"bib28","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1097\/IAE.0000000000003500","article-title":"Imaging the vitreous with a novel boosted optical coherence tomography technique: posterior vitreous detachment","volume":"42","author":"Spaide","year":"2022","journal-title":"Retina"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1136\/bjo.2004.097022","article-title":"Influence of cataract on optical coherence tomography image quality and retinal thickness","volume":"90","author":"Van Velthoven","year":"2006","journal-title":"Br J Ophthalmol"},{"issue":"12","key":"bib31","doi-asserted-by":"publisher","first-page":"2532","DOI":"10.1016\/j.ophtha.2015.08.029","article-title":"Ultrahigh speed swept source OCT angiography in non-exudative age-related macular degeneration with geographic atrophy","volume":"122","author":"Choi","year":"2015","journal-title":"Ophthalmology"},{"issue":"1","key":"bib32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-66158-8","article-title":"A neural network approach to quantify blood flow from retinal OCT intensity time-series measurements","volume":"10","author":"Braaf","year":"2020","journal-title":"Sci Rep"},{"issue":"2","key":"bib33","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1097\/01.icu.0000156134.38495.0b","article-title":"Blood flow in glaucoma","volume":"16","author":"Grieshaber","year":"2005","journal-title":"Curr Opin Ophthalmol"},{"issue":"4","key":"bib34","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/S1350-9462(02)00008-3","article-title":"The impact of ocular blood flow in glaucoma","volume":"21","author":"Flammer","year":"2002","journal-title":"Prog Retin Eye Res"},{"issue":"4","key":"bib35","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s001250051171","article-title":"Ocular blood flow and associated functional deviations in diabetic retinopathy","volume":"42","author":"Schmetterer","year":"1999","journal-title":"Diabetologia"},{"issue":"2","key":"bib36","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1038\/hr.2010.217","article-title":"Pulse wave analysis and pulse wave velocity techniques: are they ready for the clinic","volume":"34","author":"Gurovich","year":"2011","journal-title":"Hypertens Res"},{"key":"bib37","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1097\/ALN.0000000000003553","article-title":"Clinical focus review pulse wave analysis to estimate cardiac output","volume":"134","author":"Levy","year":"2021","journal-title":"Anesthesiology"},{"issue":"4","key":"bib38","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1167\/iovs.61.4.27","article-title":"Effect of changing heart rate on the ocular pulse and dynamic biomechanical behavior of the optic nerve head","volume":"61","author":"Jin","year":"2020","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"bib8","first-page":"S118","article-title":"Toward quantitative optical coherence tomography angiography: visualizing blood flow speeds in ocular: pathology using variable interscan time analysis","volume-title":"Retina","author":"Ploner","year":"2016"},{"key":"bib16","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1007\/978-3-030-16638-0_3","article-title":"Optical coherence tomography (OCT): principle and technical realization","volume-title":"High Resolution Imaging in Microscopy and Ophthalmology","author":"Aumann","year":"2019"},{"key":"bib29","first-page":"71681S","article-title":"Flow measurement by using the signal decrease of moving scatterers in spatially encoded Fourier domain optical coherence tomography","volume-title":"Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XIII","author":"Walther","year":"2009"}],"container-title":["Investigative Ophthalmology &amp; Visual Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/iovs.arvojournals.org\/article.aspx?articleid=2793725","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:31:56Z","timestamp":1791927116000},"score":1,"resource":{"primary":{"URL":"https:\/\/iovs.arvojournals.org\/article.aspx?articleid=2793725"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,5]]},"references-count":38,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6,3]]}},"URL":"https:\/\/doi.org\/10.1167\/iovs.65.6.9","relation":{},"ISSN":["1552-5783"],"issn-type":[{"value":"1552-5783","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6,5]]}}}