{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T22:02:16Z","timestamp":1791928936358,"version":"4.3.4"},"reference-count":26,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"10","license":[{"start":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T00:00:00Z","timestamp":1787702400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Invest. Ophthalmol. Vis. Sci."],"published-print":{"date-parts":[[2026,8,26]]},"DOI":"10.1167\/iovs.67.10.61","type":"journal-article","created":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:30:47Z","timestamp":1787751047000},"page":"61","source":"Crossref","is-referenced-by-count":1,"title":["Influence of Refractive Index of the Crystalline Lens on Optical Biometric Measurements for Cataract Patients"],"prefix":"10.1167","volume":"67","author":[{"given":"Ji C.","family":"He","sequence":"first","affiliation":[{"name":"New England College of Optometry, Boston, Massachusetts, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Hoover","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States"},{"name":"Duke University School of Medicine, Durham, North Carolina, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovana","family":"Gameiro","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States"},{"name":"Department of Ophthalmology and Visual Sciences, Federal University of Sao Paulo \u2013 EPM\/UNIFESP, Sao Paulo, SP, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariam","family":"Moareffi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zubair","family":"Ansari","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rahul Singh","family":"Tonk","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Zhang","sequence":"additional","affiliation":[{"name":"New England College of Optometry, Boston, Massachusetts, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianhua","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","first-page":"616","article-title":"Optical measurement of the axial eye length by laser Doppler interferometry","volume":"32","author":"Hitzenberger","year":"1991","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"bib2","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis","volume":"238","author":"Haigis","year":"2000","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1111\/opo.12182","article-title":"Refractive indices used by the Haag-Streit Lenstar to calculate axial biometric dimensions","volume":"35","author":"Suheimat","year":"2015","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"5860","DOI":"10.1364\/BOE.400471","article-title":"Standardizing sum-of segments axial length using refractive index models","volume":"11","author":"Cooke","year":"2020","journal-title":"Biomedical Opt Exp."},{"key":"bib5","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1016\/j.exer.2010.01.013","article-title":"On the growth and internal structure of the human lens","volume":"90","author":"Augusteyn","year":"2010","journal-title":"Exp Eye Res"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.preteyeres.2017.04.001","article-title":"The lens growth process","volume":"60","author":"Bassnett","year":"2017","journal-title":"Prog Retin Eye Res."},{"key":"bib7","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.exer.2016.03.009","article-title":"The cause and consequence of fiber cell compaction in the vertebrate lens","volume":"156","author":"Bassnett","year":"2017","journal-title":"Exp Eye Res."},{"key":"bib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.preteyeres.2016.09.002","article-title":"The physiological optics of the lens","volume":"56","author":"Donaldson","year":"2017","journal-title":"Prog Retin Eye Res."},{"key":"bib9","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.preteyeres.2012.03.001","article-title":"The gradient index lens of the eye: an optobiological synchrony","volume":"31","author":"Pierscionek","year":"2012","journal-title":"Prog Retin Eye Res."},{"key":"bib10","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1097\/OPX.0000000000002081","article-title":"Refractive index measurement of the crystalline lens in vivo","volume":"100","author":"He","year":"2023","journal-title":"Optom Vis Sci"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","article-title":"Calculation of intraocular lens power: a review","volume":"85","author":"Olsen","year":"2007","journal-title":"Acta Ophthalmol Scand."},{"key":"bib12","doi-asserted-by":"publisher","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","article-title":"Intraocular lens power formulas, biometry, and intraoperative aberrometry, a review","volume":"128","author":"Kane","year":"2021","journal-title":"Ophthalmology."},{"key":"bib14","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/S0886-3350(13)80917-0","article-title":"Sources of error in intraocular lens power calculation","volume":"18","author":"Olsen","year":"1992","journal-title":"J Cataract Refract Surg."},{"key":"bib15","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","article-title":"Sources of error in intraocular lens power calculation","volume":"34","author":"Norrby","year":"2008","journal-title":"J Cataract Refract Surg."},{"issue":"5","key":"bib16","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1016\/j.ajo.2014.01.016","article-title":"Whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography","volume":"157","author":"Zhong","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1364\/BOE.5.000031","article-title":"Age-dependence of the average and equivalent refractive indices of the crystalline lens","volume":"5","author":"Charman","year":"2013","journal-title":"Biomed Opt Exp."},{"issue":"5","key":"bib18","doi-asserted-by":"publisher","first-page":"2550","DOI":"10.1364\/BOE.422190","article-title":"Effect of cataract-induced refractive change on intraocular lens power formula predictions","volume":"12","author":"Cooke","year":"2021","journal-title":"Biomed Opt Express"},{"key":"bib19","doi-asserted-by":"crossref","first-page":"2732","DOI":"10.1016\/j.visres.2008.09.010","article-title":"Refractive index measurement of the isolated crystalline lens using optical coherence tomography","volume":"48","author":"Uhlhom","year":"2008","journal-title":"Vision Res."},{"key":"bib20","doi-asserted-by":"publisher","first-page":"1781","DOI":"10.1080\/09500340.2011.565888","article-title":"Age-dependent variation of the gradient index profile in human crystalline lenses","volume":"58","author":"de Castro","year":"2011","journal-title":"J Mod Opt."},{"key":"bib21","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1364\/OL.38.000085","article-title":"In vivo measurement of the average refractive index of the human crystalline lens using optical coherence tomography","volume":"38","author":"De Freitas","year":"2013","journal-title":"Opt Lett."},{"issue":"10","key":"bib22","doi-asserted-by":"publisher","first-page":"5901","DOI":"10.1364\/BOE.536501","article-title":"Age dependence of the average refractive index of the isolated human crystalline lens","volume":"15","author":"Natarajan","year":"2024","journal-title":"Biomed Opt Express"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.jcrs.2018.10.039","article-title":"A comparison of two methods to calculate axial length","volume":"45","author":"Cooke","year":"2019","journal-title":"J Cataract Refract Surg."},{"key":"bib24","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.ophtha.2018.12.046","article-title":"Calculation of axial length using a single group refractive index versus using different refractive indices for each ocular segment: theoretical study and refractive outcomes","volume":"126","author":"Wang","year":"2019","journal-title":"Ophthalmology."},{"key":"bib25","doi-asserted-by":"publisher","first-page":"4474","DOI":"10.1038\/s41598-020-61391-7","article-title":"Comparison of composite and segmental methods for acquiring optical axial length with swept-source optical coherence tomography","volume":"10","author":"Goto","year":"2020","journal-title":"Sci Rep."},{"key":"bib26","article-title":"Influence of refractive index of the crystalline lens on optical biometric measurements [published online ahead of print August 1, 2026]","author":"He","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib13","first-page":"485","article-title":"An overview of intraocular lens power calculation methods","volume-title":"Intraocular lens calculations. Essentials in Ophthalmology","author":"Fam","year":"2025"}],"container-title":["Investigative Ophthalmology &amp; Visual Science"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/iovs.arvojournals.org\/article.aspx?doi=10.1167\/iovs.67.10.61","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:32:23Z","timestamp":1791927143000},"score":1,"resource":{"primary":{"URL":"http:\/\/iovs.arvojournals.org\/article.aspx?doi=10.1167\/iovs.67.10.61"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,26]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,8,3]]}},"URL":"https:\/\/doi.org\/10.1167\/iovs.67.10.61","relation":{},"ISSN":["1552-5783"],"issn-type":[{"value":"1552-5783","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8,26]]}}}