{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T08:08:19Z","timestamp":1790669299546,"version":"4.1.0"},"reference-count":60,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"10","license":[{"start":{"date-parts":[[2021,8,12]],"date-time":"2021-08-12T00:00:00Z","timestamp":1628726400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2021,8,12]]},"DOI":"10.1167\/tvst.10.10.8","type":"journal-article","created":{"date-parts":[[2021,8,12]],"date-time":"2021-08-12T10:56:30Z","timestamp":1628765790000},"page":"8","source":"Crossref","is-referenced-by-count":25,"title":["Retinal Implantation of Electronic Vision Prostheses to Treat Retinitis Pigmentosa: A Systematic Review"],"prefix":"10.1167","volume":"10","author":[{"given":"Luke E.","family":"Hallum","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University of Auckland, Auckland, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven C.","family":"Dakin","sequence":"additional","affiliation":[{"name":"School of Optometry and Vision Science, University of Auckland, Auckland, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"1795","DOI":"10.1016\/S0140-6736(06)69740-7","article-title":"Retinitis pigmentosa","volume":"368","author":"Hartong","year":"2006","journal-title":"Lancet"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/1750-1172-1-40","article-title":"Retinitis pigmentosa","volume":"1","author":"Hamel","year":"2006","journal-title":"Orphanet J Rare Dis"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/0002-9394(84)90636-6","article-title":"Prevalence of retinitis pigmentosa in Maine","volume":"97","author":"Bunker","year":"1984","journal-title":"Am J Ophthalmol"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1111\/cge.1987.31.issue-4","article-title":"Estimation of prognosis and prevalence of retinitis pigmentosa and Usher syndrome in Norway","volume":"31","author":"Gr\u00f8ndahl","year":"1987","journal-title":"Clin Genet"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1001\/archopht.1992.01080230134038","article-title":"Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa","volume":"110","author":"Stone","year":"1992","journal-title":"Arch Ophthalmol"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1146\/annurev-vision-111815-114425","article-title":"Electrical stimulation of the retina to produce artificial vision","volume":"2","author":"Weiland","year":"2016","journal-title":"Annu Rev Vis Sci"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.ophtha.2017.09.019","article-title":"Assessment of the electronic retinal implant alpha AMS in restoring vision to blind patients with end-stage retinitis pigmentosa","volume":"125","author":"Edwards","year":"2018","journal-title":"Ophthalmology"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1001\/jamaophthalmol.2019.1476","article-title":"One-year safety and performance assessment of the Argus II retinal prosthesis: a post-approval study","volume":"137","author":"Schaffrath","year":"2019","journal-title":"JAMA Ophthalmol"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"6147","DOI":"10.1167\/iovs.16-20367","article-title":"One-year outcome of 49-channel suprachoroidal\u2013transretinal stimulation prosthesis in patients with advanced retinitis pigmentosa","volume":"57","author":"Fujikado","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"3231","DOI":"10.1167\/iovs.16-21041","article-title":"Determining the contribution of retinotopic discrimination to localization performance with a suprachoroidal retinal prosthesis","volume":"58","author":"Petoe","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"6467","DOI":"10.1167\/iovs.14-14396","article-title":"Factors affecting perceptual thresholds in a suprachoroidal retinal prosthesis","volume":"55","author":"Shivdasani","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1001\/jamaoto.2013.1744","article-title":"Cochlear implantation in adults: a systematic review and meta-analysis","volume":"139","author":"Gaylor","year":"2013","journal-title":"JAMA Otolaryngol Head Neck Surg."},{"key":"bib15","doi-asserted-by":"publisher","first-page":"264","DOI":"10.7326\/0003-4819-151-4-200908180-00135","article-title":"Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement","volume":"151","author":"Moher","year":"2009","journal-title":"Ann Intern Med"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"1255","DOI":"10.1167\/iovs.09-3512","article-title":"Basic quantitative assessment of visual performance in patients with very low vision","volume":"51","author":"Bach","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"036013","DOI":"10.1088\/1741-2560\/13\/3\/036013","article-title":"Vision function testing for a suprachoroidal retinal prosthesis: effects of image filtering","volume":"13","author":"Barnes","year":"2016","journal-title":"J Neural Eng"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1136\/bjo.2010.179622","article-title":"Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task","volume":"95","author":"Ahuja","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"2248","DOI":"10.1016\/j.ophtha.2016.06.049","article-title":"Five-year safety and performance results from the Argus II retinal prosthesis system clinical trial","volume":"123","author":"da Cruz","year":"2016","journal-title":"Ophthalmology"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.1007\/s00417-014-2912-z","article-title":"The use of Argus II retinal prosthesis by blind subjects to achieve localisation and prehension of objects in 3-dimensional space.","volume":"253","author":"Luo","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1167\/tvst.8.4.29","article-title":"Trade-off between field-of-view and resolution in the thermal-integrated Argus II system","volume":"8","author":"He","year":"2019","journal-title":"Transl Vis Sci Technol"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.visres.2015.04.006","article-title":"Oculomotor behavior of blind patients seeing with a subretinal visual implant","volume":"118","author":"Hafed","year":"2016","journal-title":"Vision Res"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"e1002569","DOI":"10.1371\/journal.pbio.1002569","article-title":"Visual BOLD response in late blind subjects with Argus II retinal prosthesis","volume":"14","author":"Castaldi","year":"2016","journal-title":"PLoS Biol"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"16","DOI":"10.5301\/ejo.5000852","article-title":"Optical coherence tomography imaging in the management of the Argus II retinal prosthesis system","volume":"27","author":"Parmeggiani","year":"2017","journal-title":"Eur J Ophthalmol"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"1723","DOI":"10.1007\/s00417-018-3982-0","article-title":"Light localization with low-contrast targets in a patient implanted with a suprachoroidal\u2013transretinal stimulation retinal prosthesis","volume":"256","author":"Endo","year":"2018","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"41","DOI":"10.3389\/fnsys.2016.00041","article-title":"Hand-camera coordination varies over time in users of the Argus II retinal prosthesis system","volume":"10","author":"Barry","year":"2016","journal-title":"Front Syst Neurosci"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1167\/iovs.17-22377","article-title":"Eye movement control in the Argus II retinal-prosthesis enables reduced head movement and better localization precision","volume":"59","author":"Caspi","year":"2018","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1097\/JCMA.0000000000000091","article-title":"First implantation of retinal prosthesis in a patient with high myopia after surgery and rehabilitation program in Taiwan","volume":"82","author":"Hsu","year":"2019","journal-title":"J Chin Med Assoc"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1016\/j.ophtha.2015.04.032","article-title":"Long-term results from an epiretinal prosthesis to restore sight to the blind","volume":"122","author":"Ho","year":"2015","journal-title":"Ophthalmology"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.visres.2015.03.001","article-title":"Subretinal visual implant alpha IMS\u2013clinical trial interim report","volume":"111","author":"Stingl","year":"2015","journal-title":"Vision Res"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"445","DOI":"10.3389\/fnins.2017.00445","article-title":"Interim results of a multicenter trial with the new electronic subretinal implant Alpha AMS in 15 patients blind from inherited retinal degenerations","volume":"11","author":"Stingl","year":"2017","journal-title":"Front Neurosci"},{"key":"bib32","first-page":"52","article-title":"A bionic eye: performance of the Argus II retinal prosthesis in low-vision and social rehabilitation of patients with end-stage retinitis pigmentosa","volume":"3","author":"KhP","year":"2019","journal-title":"Bulletin of the Russian State Medical University"},{"key":"bib33","doi-asserted-by":"publisher","first-page":"2545","DOI":"10.1016\/j.ophtha.2015.08.008","article-title":"Ten-year follow-up of a blind patient chronically implanted with epiretinal prosthesis Argus I","volume":"122","author":"Yue","year":"2015","journal-title":"Ophthalmology"},{"key":"bib34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1037\/h0054051","article-title":"Acquisition and extinction of a verbal conditioned response with differing percentages of reinforcement","volume":"42","author":"Grant","year":"1951","journal-title":"J Exp Psychol"},{"key":"bib35","doi-asserted-by":"publisher","first-page":"e1000871","DOI":"10.1371\/journal.pcbi.1000871","article-title":"Probability matching as a computational strategy used in perception","volume":"6","author":"Wozny","year":"2010","journal-title":"PLoS Comput Biol"},{"key":"bib36","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1001\/2013.jamaophthalmol.221","article-title":"The detection of motion by blind subjects with the epiretinal 60-electrode (Argus II) retinal prosthesis","volume":"131","author":"Dorn","year":"2013","journal-title":"JAMA Ophthalmol"},{"key":"bib37","doi-asserted-by":"publisher","first-page":"e0134369","DOI":"10.1371\/journal.pone.0134369","article-title":"Visual and non-visual navigation in blind patients with a retinal prosthesis","volume":"10","author":"Garcia","year":"2015","journal-title":"PLoS One"},{"key":"bib38","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1111\/ceo.2017.45.issue-2","article-title":"Performance of real-world functional vision tasks by blind subjects improves after implantation with the Argus II retinal prosthesis system","volume":"45","author":"Dagnelie","year":"2017","journal-title":"Clin Exp Ophthalmol"},{"key":"bib39","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.ophtha.2018.11.010","article-title":"Six-month safety and efficacy of the Intelligent Retinal Implant System II device in retinitis pigmentosa","volume":"126","author":"Muqit","year":"2019","journal-title":"Ophthalmology"},{"key":"bib40","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1111\/cxo.12359","article-title":"An analysis of observer-rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years","volume":"99","author":"Geruschat","year":"2016","journal-title":"Clin Exp Optom"},{"key":"bib41","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1111\/cxo.12444","article-title":"Improvements in vision-related quality of life in blind patients implanted with the Argus II Epiretinal Prosthesis","volume":"100","author":"Duncan","year":"2017","journal-title":"Clin Exp Optom"},{"key":"bib43","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1288\/00005537-198809000-00015","article-title":"Evaluation of five different cochlear implant designs: audiologic assessment and predictors of performance","volume":"98","author":"Tyler","year":"1988","journal-title":"Laryngoscope"},{"key":"bib44","first-page":"345","article-title":"Blinding: Who, what, when, why, how?","volume":"53","author":"Karanicolas","year":"2010","journal-title":"Can J Surg"},{"key":"bib45","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1016\/S0140-6736(02)07816-9","article-title":"Blinding in randomised trials: hiding who got what","volume":"359","author":"Schulz","year":"2002","journal-title":"Lancet"},{"key":"bib46","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1136\/bmj.39465.451748.AD","article-title":"Empirical evidence of bias in treatment effect estimates in controlled trials with different interventions and outcomes: meta-epidemiological study","volume":"336","author":"Wood","year":"2008","journal-title":"Br Med J"},{"key":"bib48","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1016\/S0895-4356(00)00206-7","article-title":"Do medical devices have enhanced placebo effects?","volume":"53","author":"Kaptchuk","year":"2000","journal-title":"J Clin Epidemiol"},{"key":"bib49","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1097\/00006324-199601000-00008","article-title":"The \u201cFreiburg visual acuity test\u201d - automatic measurement of visual acuity","volume":"73","author":"Bach","year":"1996","journal-title":"Optom Vis Sci"},{"key":"bib50","doi-asserted-by":"publisher","first-page":"20130077","DOI":"10.1098\/rspb.2013.0077","article-title":"Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS","volume":"280","author":"Stingl","year":"2013","journal-title":"Proc R Soc B Biol Sci"},{"key":"bib51","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1016\/j.ajo.2007.01.027","article-title":"Visual performance using a retinal prosthesis in three subjects with retinitis pigmentosa","volume":"143","author":"Yanai","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"bib52","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.preteyeres.2015.09.003","article-title":"The Argus II retinal prosthesis system","volume":"50","author":"Luo","year":"2016","journal-title":"Prog Retin Eye Res"},{"key":"bib53","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1001\/jamaophthalmol.2018.6375","article-title":"Assessment of postoperative morphologic retinal changes by optical coherence tomography in recipients of an electronic retinal prosthesis implant","volume":"137","author":"Rizzo","year":"2019","journal-title":"JAMA Ophthalmol"},{"key":"bib54","doi-asserted-by":"publisher","first-page":"025002","DOI":"10.1088\/1741-2552\/aafc76","article-title":"The first deaf-blind patient in Russia with Argus II retinal prosthesis system: what he sees and why","volume":"16","author":"Demchinsky","year":"2019","journal-title":"J Neural Eng"},{"key":"bib55","doi-asserted-by":"publisher","first-page":"S89","DOI":"10.1016\/j.ophtha.2016.06.044","article-title":"The bionic eye: a quarter century of retinal prosthesis research and development","volume":"123","author":"Humayun","year":"2016","journal-title":"Ophthalmology"},{"key":"bib56","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1167\/tvst.9.8.25","article-title":"Harmonization of outcomes and vision endpoints in vision restoration trials: recommendations from the international HOVER taskforce","volume":"9","author":"Ayton","year":"2020","journal-title":"Transl Vis Sci Technol"},{"key":"bib57","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1016\/j.visres.2004.09.032","article-title":"Simulated prosthetic visual fixation, saccade, and smooth pursuit","volume":"45","author":"Hallum","year":"2005","journal-title":"Vision Res"},{"key":"bib58","doi-asserted-by":"publisher","first-page":"S108","DOI":"10.1088\/1741-2560\/4\/1\/S13","article-title":"A quantitative analysis of head movement behaviour during visual acuity assessment under prosthetic vision simulation","volume":"4","author":"Chen","year":"2007","journal-title":"J Neural Eng"},{"issue":"13","key":"bib59","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1167\/tvst.9.13.32","article-title":"Testing vision is not testing for vision","volume":"9","author":"Peli","year":"2020","journal-title":"Transl Vis Sci Technol"},{"issue":"3","key":"bib60","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1167\/tvst.6.3.10","article-title":"Living with ultra-low vision: an inventory of self-reported visually guided activities by individuals with profound visual impairment","volume":"6","author":"Adeyemo","year":"2017","journal-title":"Transl Vis Sci Technol"},{"key":"bib13","doi-asserted-by":"crossref","DOI":"10.1002\/9781119536604.ch8","article-title":"Chapter 8: Assessing risk of bias in a randomized trial. Draft version (29 January 2019) for inclusion","volume-title":"Cochrane Handbook for Systematic Reviews of Interventions","author":"Higgins","year":"2019.","edition":"2nd edition"},{"key":"bib14","doi-asserted-by":"crossref","DOI":"10.1002\/9781119536604.ch25","article-title":"Chapter 25: assessing risk of bias in a non-randomized study. Draft version (29 January 2019) for inclusion","volume-title":"Cochrane Handbook for Systematic Reviews of Interventions","author":"Sterne","year":"2019"},{"key":"bib42","doi-asserted-by":"crossref","DOI":"10.1093\/acprof:oso\/9780195051544.001.0001","volume-title":"Visual Pattern Analyzers","author":"Graham NVS","year":"1989"},{"key":"bib47","doi-asserted-by":"crossref","DOI":"10.1093\/acref\/9780199976720.001.0001","volume-title":"A Dictionary of Epidemiology","author":"Porta","year":"2014"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2776582","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,12]],"date-time":"2021-08-12T10:56:39Z","timestamp":1628765799000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2776582"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,12]]},"references-count":60,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,8,12]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.10.10.8","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2020.11.30.20234476","asserted-by":"object"}]},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8,12]]}}}