{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T14:59:24Z","timestamp":1792681164711,"version":"4.5.0"},"reference-count":36,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"11","license":[{"start":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T00:00:00Z","timestamp":1632700800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2021,9,27]]},"DOI":"10.1167\/tvst.10.11.21","type":"journal-article","created":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T18:51:17Z","timestamp":1632768677000},"page":"21","source":"Crossref","is-referenced-by-count":29,"title":["A Deep Learning System for Automatic Assessment of Anterior Chamber Angle in Ultrasound Biomicroscopy Images"],"prefix":"10.1167","volume":"10","author":[{"given":"Wensai","family":"Wang","sequence":"first","affiliation":[{"name":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingxiao","family":"Wang","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaochun","family":"Wang","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng","family":"Zhou","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Song","family":"Lin","sequence":"additional","affiliation":[{"name":"Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Yang","sequence":"additional","affiliation":[{"name":"Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1136\/bjo.85.11.1277","article-title":"Glaucoma in China: how big is the problem?","volume":"85","author":"Foster","year":"2001","journal-title":"Br J Ophthalmol"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1136\/bjo.2005.081224","article-title":"The number of people with glaucoma worldwide in 2010 and 2020","volume":"90","author":"Quigley","year":"2006","journal-title":"Br J Ophthalmol"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"2081","DOI":"10.1016\/j.ophtha.2014.05.013","article-title":"Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis","volume":"121","author":"Tham","year":"2014","journal-title":"Ophthalmology"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.preteyeres.2016.12.003","article-title":"Primary angle closure glaucoma: what we know and what we don't know","volume":"57","author":"Sun","year":"2017","journal-title":"Prog Retin Eye Res"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1097\/ICU.0b013e32834372b9","article-title":"Angle closure glaucoma: a mechanistic review","volume":"22","author":"Nongpiur","year":"2011","journal-title":"Curr Opin Ophthalmol"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1001\/jama.2014.3192","article-title":"The pathophysiology and treatment of glaucoma: a review","volume":"311","author":"Weinreb","year":"2014","journal-title":"JAMA"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"3814","DOI":"10.3390\/jcm9123814","article-title":"Anterior chamber angle assessment techniques: a review","volume":"9","author":"Riva","year":"2020","journal-title":"J Clin Med"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1001\/archopht.125.10.1331","article-title":"Agreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition","volume":"125","author":"Barkana","year":"2007","journal-title":"Arch Ophthalmol"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1001\/archopht.1966.03850010490005","article-title":"Gonioscopy with corneal indentation: a method for distinguishing between appositional closure and synechial closure","volume":"76","author":"Forbes","year":"1966","journal-title":"Arch Ophthalmol"},{"key":"bib10","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1016\/j.medengphy.2016.09.014","article-title":"Progress in anterior chamber angle imaging for glaucoma risk prediction\u2014A review on clinical equipment, practice and research","volume":"38","author":"Shinoj","year":"2016","journal-title":"Med Eng Phys"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1016\/j.ophtha.2006.06.053","article-title":"Laser peripheral iridotomy in primary angle-closure suspects: biometric and gonioscopic outcomes: the Liwan Eye Study","volume":"114","author":"He","year":"2007","journal-title":"Ophthalmology"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/S0161-6420(91)32298-X","article-title":"Clinical use of ultrasound biomicroscopy","volume":"98","author":"Pavlin","year":"1991","journal-title":"Ophthalmology"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.survophthal.2007.10.012","article-title":"Anterior chamber angle assessment techniques","volume":"53","author":"Friedman","year":"2008","journal-title":"Surv Ophthalmol"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/S0002-9394(14)76159-8","article-title":"Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes","volume":"113","author":"Pavlin","year":"1992","journal-title":"Am J Ophthalmol"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1016\/S0021-5155(99)00139-2","article-title":"Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width","volume":"43","author":"Ishikawa","year":"1999","journal-title":"Jpn J Ophthalmol"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1167\/tvst.8.4.25","article-title":"Automatic classification of anterior chamber angle using ultrasound biomicroscopy and deep learning","volume":"8","author":"Shi","year":"2019","journal-title":"Transl Vis Sci Technol"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ajo.2019.02.028","article-title":"A deep learning system for automated angle-closure detection in anterior segment optical coherence tomography images","volume":"203","author":"Fu","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/j.ajo.2019.08.004","article-title":"Deep learning classifiers for automated detection of gonioscopic angle closure based on anterior segment OCT images","volume":"208","author":"Xu","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"3358","DOI":"10.1109\/TCYB.6221036","article-title":"Angle-closure detection in anterior segment OCT based on multilevel deep network","volume":"50","author":"Fu","year":"2020","journal-title":"IEEE Trans Cybern"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"101956","DOI":"10.1016\/j.media.2021.101956","article-title":"Angle-closure assessment in anterior segment OCT images via deep learning","volume":"69","author":"Hao","year":"2021","journal-title":"Med Image Anal"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1007\/s11263-015-0816-y","article-title":"ImageNet large scale visual recognition challenge","volume":"115","author":"Russakovsky","year":"2015","journal-title":"Int J Comput Vision"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/j.ajo.2010.11.030","article-title":"Comparison of ultrasound biomicroscopic configurations among primary angle closure, its suspects, and nonoccludable angles: the Kumejima Study","volume":"151","author":"Henzan","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"xvi","DOI":"10.1016\/j.ajo.2018.01.006","article-title":"Anterior segment imaging for angle closure","volume":"188","author":"Chansangpetch","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.ajo.2014.06.005","article-title":"Clinical results of posterior chamber phakic intraocular lens implantation in eyes with low anterior chamber depth","volume":"158","author":"Lim","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.ophtha.2004.10.026","article-title":"Prevalence of appositional angle closure determined by ultrasonic biomicroscopy in eyes with shallow anterior chambers","volume":"112","author":"Kunimatsu","year":"2005","journal-title":"Ophthalmology"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1007\/978-3-319-24574-4","article-title":"U-Net: convolutional networks for biomedical image segmentation","volume":"9351","author":"Ronneberger","year":"2015","journal-title":"Lect Notes Comput Sci"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1097\/01.ijg.0000212285.55174.f5","article-title":"Gender variation in ocular biometry and ultrasound biomicroscopy of primary angle closure suspects and normal eyes","volume":"16","author":"Ramani","year":"2007","journal-title":"J Glaucoma"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1097\/IJG.0b013e3181911258","article-title":"Ultrasound biomicroscopy in narrow peripheral anterior chamber eyes with or without peripheral anterior synechiae","volume":"18","author":"Hirasawa","year":"2009","journal-title":"J Glaucoma"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1016\/j.ophtha.2008.10.019","article-title":"Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy","volume":"116","author":"Yao","year":"2009","journal-title":"Ophthalmology"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1097\/00055735-200004000-00012","article-title":"Quantitative assessment of the anterior segment using ultrasound biomicroscopy","volume":"11","author":"Ishikawa","year":"2000","journal-title":"Curr Opin Ophthalmol"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1136\/bjo.2007.129932","article-title":"Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program","volume":"92","author":"Console","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"bib32","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/IJG.0b013e3182698094","article-title":"Reproducibility of anterior chamber angle measurement using the Tongren ultrasound biomicroscopy analysis system","volume":"23","author":"Lin","year":"2014","journal-title":"J Glaucoma"},{"key":"bib33","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/IJG.0000000000001411","article-title":"Automatic anterior chamber angle measurement for ultrasound biomicroscopy using deep learning","volume":"29","author":"Li","year":"2020","journal-title":"J Glaucoma"},{"key":"bib34","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1016\/j.ophtha.2011.12.038","article-title":"Prevalence of primary angle closure and primary angle-closure glaucoma in a southwestern rural population of Japan: the Kumejima Study","volume":"119","author":"Sawaguchi","year":"2012","journal-title":"Ophthalmology"},{"issue":"1","key":"bib36","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1038\/s41746-020-00350-y","article-title":"Deep learning from \u201cpassive feeding\u201d to \u201cselective eating\u201d of real-world data","volume":"3","author":"Li","year":"2020","journal-title":"Npj Digit Med"},{"key":"bib35","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9781107298019","volume-title":"Understanding Machine Learning: From Theory to Algorithms","author":"Shalev-Shwartz","year":"2014"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2777933","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T18:51:23Z","timestamp":1632768683000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2777933"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,27]]},"references-count":36,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021,9,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.10.11.21","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2021,9,27]]}}}