{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T03:27:54Z","timestamp":1771644474693,"version":"3.50.1"},"reference-count":34,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"9","license":[{"start":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T00:00:00Z","timestamp":1630281600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2021,8,30]]},"DOI":"10.1167\/tvst.10.9.36","type":"journal-article","created":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T15:30:58Z","timestamp":1630337458000},"page":"36","source":"Crossref","is-referenced-by-count":9,"title":["A Novel Indentation Assessment to Measure Corneal Biomechanical Properties in Glaucoma and Ocular Hypertension"],"prefix":"10.1167","volume":"10","author":[{"given":"Yunzhi","family":"Xu","sequence":"first","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yiming","family":"Ye","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iok Tong","family":"Chong","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zidong","family":"Chen","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiangang","family":"Xu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yangfan","family":"Yang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keming","family":"Yu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David C. C.","family":"Lam","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minbin","family":"Yu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.ajo.2017.12.018","article-title":"A prospective longitudinal study to investigate corneal hysteresis as a risk factor for predicting development of glaucoma","volume":"187","author":"Susanna","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"1640","DOI":"10.1016\/j.ophtha.2019.07.023","article-title":"Corneal biomechanics and visual field progression in eyes with seemingly well-controlled intraocular pressure","volume":"126","author":"Susanna","year":"2019","journal-title":"Ophthalmology"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"4990","DOI":"10.1167\/iovs.17-22219","article-title":"Impact of myopia on corneal biomechanics in glaucoma and nonglaucoma patients","volume":"58","author":"Chansangpetch","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambrosio","year":"2017","journal-title":"J Refract Surg"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1097\/IJG.0000000000000133","article-title":"Corneal deformation parameters provided by the Corvis-ST pachy-tonometer in healthy subjects and glaucoma patients","volume":"24","author":"Salvetat","year":"2015","journal-title":"J Glaucoma"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"266","DOI":"10.3928\/1081597X-20161221-03","article-title":"Introduction of two novel stiffness parameters and interpretation of air puff-induced biomechanical deformation parameters with a dynamic Scheimpflug analyzer","volume":"33","author":"Roberts","year":"2017","journal-title":"J Refract Surg"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer","volume":"31","author":"Luce","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1016\/j.jcrs.2014.04.019","article-title":"Concepts and misconceptions in corneal biomechanics","volume":"40","author":"Roberts","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1111\/opo.12345","article-title":"Corneal biomechanics - a review","volume":"37","author":"Kling","year":"2017","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1097\/IJG.0000000000000774","article-title":"In vivo noninvasive measurement of young's modulus of elasticity in human eyes: a feasibility study","volume":"26","author":"Sit","year":"2017","journal-title":"J Glaucoma"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"e263","DOI":"10.1111\/aos.2013.91.issue-4","article-title":"Characterization of corneal tangent modulus in vivo","volume":"91","author":"Ko","year":"2013","journal-title":"Acta Ophthalmol"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1111\/opo.2015.35.issue-4","article-title":"Repeatability of a novel corneal indentation device for corneal biomechanical measurement","volume":"35","author":"Lam","year":"2015","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.medengphy.2014.06.003","article-title":"Comparative study of corneal tangent elastic modulus measurement using corneal indentation device","volume":"36","author":"Ko","year":"2014","journal-title":"Med Eng Phys"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"1600","DOI":"10.1097\/ICO.0000000000000968","article-title":"Diurnal variation of corneal tangent modulus in normal Chinese","volume":"35","author":"Hon","year":"2016","journal-title":"Cornea"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1167\/tvst.8.5.10","article-title":"Characterization of corneal biomechanical properties and determination of natural intraocular pressure using CID-GAT","volume":"8","author":"Lu","year":"2019","journal-title":"Transl Vis Sci Technol"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1111\/opo.2017.37.issue-1","article-title":"High myopes have lower normalised corneal tangent moduli (less 'stiff' corneas) than low myopes","volume":"37","author":"Hon","year":"2017","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1080\/02713683.2017.1418895","article-title":"Influence of short-term orthokeratology to corneal tangent modulus: a randomized study","volume":"43","author":"Lam","year":"2018","journal-title":"Current Eye Res"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1097\/IJG.0000000000000745","article-title":"Comparison of central corneal thickness measurements using ultrasonic pachymetry, anterior segment OCT and noncontact specular microscopy","volume":"26","author":"Scotto","year":"2017","journal-title":"J Glaucoma"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1590\/S0004-27492013000500005","article-title":"Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging","volume":"76","author":"Correia","year":"2013","journal-title":"Arq Brasil Oftalmol"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1186\/1475-925X-13-150","article-title":"Automatic method of analysis and measurement of additional parameters of corneal deformation in the Corvis tonometer","volume":"13","author":"Koprowski","year":"2014","journal-title":"Biomed Eng Online"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"730","DOI":"10.3928\/1081597X-20191010-03","article-title":"Corneal viscous properties cannot be determined from air-puff applanation","volume":"35","author":"Francis","year":"2019","journal-title":"J Refract Surg"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1002\/jbio.v9.5","article-title":"In vivo human corneal deformation analysis with a Scheimpflug camera, a critical review","volume":"9","author":"Lanza","year":"2016","journal-title":"J Biophotonics"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"2367","DOI":"10.1016\/j.jbiomech.2006.12.001","article-title":"Stress-controlled viscoelastic tensile response of bovine cornea","volume":"40","author":"Boyce","year":"2007","journal-title":"J Biomech"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"127","DOI":"10.3928\/1081-597X-19920301-07","article-title":"Introduction to biomechanics of the cornea","volume":"8","author":"Buzard","year":"1992","journal-title":"Refract Corneal Surg"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1016\/j.exer.2008.02.006","article-title":"Biomechanical properties of human and porcine corneas","volume":"86","author":"Elsheikh","year":"2008","journal-title":"Exp Eye Res"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1167\/iovs.11-8720","article-title":"Biomechanics of the anterior human corneal tissue investigated with atomic force microscopy","volume":"53","author":"Lombardo","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.exer.2013.06.004","article-title":"Anterior and posterior corneal stroma elasticity assessed using nanoindentation","volume":"115","author":"Dias","year":"2013","journal-title":"Exp Eye Res"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of keratoconus with a new biomechanical index","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","article-title":"Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis","volume":"31","author":"Liu","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"468","DOI":"10.3928\/1081597X-20140521-01","article-title":"Ocular biomechanical metrics by CorVis ST in healthy Brazilian patients","volume":"30","author":"Valbon","year":"2014","journal-title":"J Refract Surg"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1097\/ICO.0000000000001605","article-title":"Corneal stiffness and its relationship with other corneal biomechanical and nonbiomechanical parameters in myopic eyes of Chinese patients","volume":"37","author":"Zhang","year":"2018","journal-title":"Cornea"},{"key":"bib32","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1053\/apmr.2002.33985","article-title":"The law of Laplace and its relevance to contemporary medicine and rehabilitation","volume":"83","author":"Basford","year":"2002","journal-title":"Arch Phys Med Rehabil"},{"key":"bib33","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.exer.2006.03.015","article-title":"Biomechanics and wound healing in the cornea","volume":"83","author":"Dupps","year":"2006","journal-title":"Exp Eye Res"},{"key":"bib34","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s12938-017-0311-5","article-title":"Effects of ablation depth and repair time on the corneal elastic modulus after laser in situ keratomileusis","volume":"16","author":"Wang","year":"2017","journal-title":"Biomed Eng Online"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2776741","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T15:31:01Z","timestamp":1630337461000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2776741"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,30]]},"references-count":34,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2021,8,2]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.10.9.36","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8,30]]}}}