{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T13:36:45Z","timestamp":1792589805984,"version":"4.5.0"},"reference-count":24,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"4","license":[{"start":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T00:00:00Z","timestamp":1649635200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2022,4,11]]},"DOI":"10.1167\/tvst.11.4.9","type":"journal-article","created":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T14:31:04Z","timestamp":1649687464000},"page":"9","source":"Crossref","is-referenced-by-count":6,"title":["Tissue Reactivity to, and Stability of, Glaucoma Drainage Device Materials Placed Under Rabbit Conjunctiva"],"prefix":"10.1167","volume":"11","author":[{"given":"Kenichi","family":"Nakamura","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomokazu","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miho","family":"Okada","sequence":"additional","affiliation":[{"name":"Pharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kentaro","family":"Maki","sequence":"additional","affiliation":[{"name":"Pharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Shimazaki","sequence":"additional","affiliation":[{"name":"Pharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masatomo","family":"Kato","sequence":"additional","affiliation":[{"name":"Pharmaceutics and Pharmacology Department, Santen Pharmaceutical Co., Ltd., Nara, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihiro","family":"Inoue","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","first-page":"774","article-title":"Retinal ganglion cell death in experimental glaucoma and after axotomy occurs by apoptosis","volume":"36","author":"Quigley","year":"1995","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib2","first-page":"168","article-title":"Recent developments in understanding the pathophysiology of elevated intraocular pressure","volume":"17","author":"Tan","year":"2006","journal-title":"Curr Opin Ophthalmol"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.1016\/j.ophtha.2007.02.005","article-title":"Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004","volume":"114","author":"Ramulu","year":"2007","journal-title":"Ophthalmology"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.ajo.2013.09.014","article-title":"Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study)","volume":"157","author":"Netland","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/S0002-9394(03)00239-3","article-title":"Long-term follow-up of primary glaucoma surgery with Ahmed glaucoma valve implant versus trabeculectomy","volume":"136","author":"Wilson","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1016\/j.ajo.2011.10.026","article-title":"Treatment outcomes in the Tube Versus Trabeculectomy (TVT) study after five years of follow-up","volume":"153","author":"Gedde","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"19337","DOI":"10.1038\/s41598-020-76551-y","article-title":"Comparing the efficacy of trabeculectomy and XEN gel microstent implantation for the treatment of primary open-angle glaucoma: a retrospective monocentric comparative cohort study","volume":"10","author":"Theilig","year":"2020","journal-title":"Sci Rep"},{"issue":"Pt 2","key":"bib8","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1038\/eye.1994.44","article-title":"Activation and suppression of fibroblast function","volume":"8","author":"Khaw","year":"1994","journal-title":"Eye (Lond)"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1016\/j.ophtha.2006.01.062","article-title":"Trabeculectomy with mitomycin C: outcomes and risk factors for failure in phakic open-angle glaucoma","volume":"113","author":"Fontana","year":"2006","journal-title":"Ophthalmology"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1161\/CIRCULATIONAHA.109.849877","article-title":"Final 5-year results of the TAXUS II trial: a randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for de novo coronary artery lesions","volume":"120","author":"Silber","year":"2009","journal-title":"Circulation"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"1742","DOI":"10.1001\/archopht.124.12.1742","article-title":"A newly designed glaucoma drainage implant made of poly(styrene-b-isobutylene-b-styrene): biocompatibility and function in normal rabbit eyes","volume":"124","author":"Acosta","year":"2006","journal-title":"Arch Ophthalmol"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.biomaterials.2007.09.041","article-title":"Medical applications of poly(styrene-block-isobutylene-block-styrene) (\u201cSIBS\u201d)","volume":"29","author":"Pinchuk","year":"2008","journal-title":"Biomaterials"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1002\/jbm.b.v105.1","article-title":"The development of a micro-shunt made from poly(styrene-block-isobutylene-block-styrene) to treat glaucoma","volume":"105","author":"Pinchuk","year":"2017","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"1710","DOI":"10.1016\/j.ophtha.2021.05.023","article-title":"Ab-Externo MicroShunt versus trabeculectomy in primary open-angle glaucoma: one-year results from a 2-year randomized, multicenter study","volume":"128","author":"Baker","year":"2021","journal-title":"Ophthalmology"},{"key":"bib15","article-title":"PRESERFLO MicroShunt versus trabeculectomy: First results on efficacy and safety [published online ahead of print July 31, 2021]","author":"Pillunat","journal-title":"Acta Ophthalmol"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1167\/tvst.10.9.9","article-title":"Intraocular pressure-lowering effects of trabeculectomy versus microshunt insertion in rabbit eyes","volume":"10","author":"Fujimoto","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1001\/archopht.117.2.233","article-title":"Comparison of different biomaterials for glaucoma drainage devices","volume":"117","author":"Ayyala","year":"1999","journal-title":"Arch Ophthalmol"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1001\/archopht.118.8.1081","article-title":"Comparison of different biomaterials for glaucoma drainage devices: part 2","volume":"118","author":"Ayyala","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"3594","DOI":"10.1167\/iovs.16-19453","article-title":"Biocompatibility of a novel microfistula implant in nonprimate mammals for the surgical treatment of glaucoma","volume":"57","author":"Shute","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"643","DOI":"10.2147\/OPTH","article-title":"Conventional trabeculectomy versus trabeculectomy with the Ex-PRESS mini-glaucoma shunt: differences in postoperative interventions","volume":"12","author":"Tojo","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1097\/01.ijg.0000243479.90403.cd","article-title":"Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap","volume":"16","author":"Maris","year":"2007","journal-title":"J Glaucoma"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.ajo.2010.09.004","article-title":"Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy","volume":"151","author":"Good","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"e171","DOI":"10.1097\/IJG.0000000000001364","article-title":"Intraocular degradation of XEN45 gel stent 3 years after its implantation","volume":"28","author":"Widder","year":"2019","journal-title":"J Glaucoma"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"e433","DOI":"10.1111\/aos.v99.3","article-title":"XEN Gel Stent compared to PRESERFLO MicroShunt implantation for primary open-angle glaucoma: two-year results","volume":"99","author":"Scheres","year":"2021","journal-title":"Acta Ophthalmol"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2778737","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T14:31:11Z","timestamp":1649687471000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2778737"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,11]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.11.4.9","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4,11]]}}}