{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T13:50:31Z","timestamp":1791985831662,"version":"4.4.0"},"reference-count":32,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"3","license":[{"start":{"date-parts":[[2023,3,16]],"date-time":"2023-03-16T00:00:00Z","timestamp":1678924800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2023,3,16]]},"DOI":"10.1167\/tvst.12.3.13","type":"journal-article","created":{"date-parts":[[2023,3,16]],"date-time":"2023-03-16T15:31:01Z","timestamp":1678980661000},"page":"13","source":"Crossref","is-referenced-by-count":26,"title":["Agreement of Total Keratometry and Posterior Keratometry Among IOLMaster 700, CASIA2, and Pentacam"],"prefix":"10.1167","volume":"12","author":[{"given":"Aixia","family":"Jin","sequence":"first","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaotong","family":"Han","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaqing","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaozhang","family":"Qiu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifan","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Qu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuhua","family":"Tan","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lixia","family":"Luo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China"},{"name":"Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","article-title":"Contribution of posterior corneal astigmatism to total corneal astigmatism","volume":"38","author":"Koch","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"bib2","doi-asserted-by":"crossref","first-page":"2840246","DOI":"10.1155\/2018\/2840246","article-title":"Comparison of Two Toric IOL Calculation Methods","volume":"2018","author":"Kern","year":"2018","journal-title":"J Ophthalmol"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1097\/j.jcrs.0000000000000136","article-title":"Evaluation of total corneal power measurements with a new optical biometer","volume":"46","author":"Shajari","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1016\/j.ophtha.2015.01.021","article-title":"Corneal thickness profile and posterior corneal astigmatism in normal corneas","volume":"122","author":"Ueno","year":"2015","journal-title":"Ophthalmology"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"2677","DOI":"10.1007\/s00417-019-04443-7","article-title":"Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery","volume":"257","author":"Srivannaboon","year":"2019","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","article-title":"Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery","volume":"45","author":"Wang","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"362","DOI":"10.3928\/1081597X-20190422-02","article-title":"Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas","volume":"35","author":"Fabian","year":"2019","journal-title":"J Refract Surg"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1167\/iovs.14-15659","article-title":"Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism","volume":"56","author":"Tonn","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.jcrs.2015.11.036","article-title":"Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: Comparison of methodologies","volume":"42","author":"Reitblat","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"1652","DOI":"10.1097\/j.jcrs.0000000000000327","article-title":"Posterior and total corneal astigmatism measured with optical coherence tomography-based biometer and dual Scheimpflug analyzer","volume":"46","author":"Wang","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1097\/ICO.0000000000002280","article-title":"Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature","volume":"39","author":"Zhang","year":"2020","journal-title":"Cornea"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"201","DOI":"10.3928\/1081597X-20220110-01","article-title":"Repeatability and Agreement of a New Scheimpflug Device and a Hartmann-Shack Aberrometer With a Ray-Tracing Aberrometer in Normal, Keratoconus, and CXL Groups","volume":"38","author":"Kundu","year":"2022","journal-title":"J Refract Surg"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ajo.2017.02.027","article-title":"Comparison of Axial Length, Corneal Curvature, and Anterior Chamber Depth Measurements of 2 Recently Introduced Devices to a Known Biometer","volume":"178","author":"Shajari","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1097\/j.jcrs.0000000000000731","article-title":"Agreement between swept-source optical biometry and Scheimpflug-based topography measurements of posterior corneal curvature","volume":"48","author":"Kose","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/00006324-199706000-00019","article-title":"Power vectors: An application of Fourier analysis to the description and statistical analysis of refractive error","volume":"74","author":"Thibos","year":"1997","journal-title":"Optom Vis Sci"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1097\/OPX.0000000000001113","article-title":"Comparison of Refractive Measures of Three Autorefractors in Children and Adolescents","volume":"94","author":"Xiong","year":"2017","journal-title":"Optom Vis Sci"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1016\/j.ophtha.2015.01.022","article-title":"The posterior cornea: Hiding in plain sight","volume":"122","author":"Koch","year":"2015","journal-title":"Ophthalmology"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jcrs.2015.12.005","article-title":"Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes","volume":"42","author":"Chen","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.jaapos.2007.10.012","article-title":"Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients","volume":"12","author":"Eibschitz-Tsimhoni","year":"2008","journal-title":"J AAPOS"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1186\/s12886-021-01826-5","article-title":"Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices","volume":"21","author":"Oh","year":"2021","journal-title":"BMC Ophthalmol"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1111\/ceo.v48.6","article-title":"Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery","volume":"48","author":"Lawless","year":"2020","journal-title":"Clin Exp Ophthalmol"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1097\/j.jcrs.0000000000000633","article-title":"Repeatability of 2 swept-source OCT biometers and 1\u00a0optical low-coherence reflectometry biometer","volume":"47","author":"Fisus","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.clae.2017.03.007","article-title":"Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements","volume":"40","author":"Sel","year":"2017","journal-title":"Cont Lens Anterior Eye"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1097\/j.jcrs.0000000000000766","article-title":"Accuracy of OCT-derived net corneal astigmatism measurement","volume":"48","author":"Llorens-Quintana","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1016\/j.jcrs.2012.11.022","article-title":"Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera","volume":"39","author":"Savini","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/ICO.0000000000002052","article-title":"Comparison of Corneal Power and Corneal Astigmatism of Different Diameter Zones Centered on the Pupil and Corneal Apex Using Scheimpflug Tomography","volume":"39","author":"Dong","year":"2020","journal-title":"Cornea"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1111\/opo.2010.30.issue-6","article-title":"Keratometry measurements, corneal astigmatism and irregularity in a normal population: The Tehran Eye Study","volume":"30","author":"KhabazKhoob","year":"2010","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"777443","DOI":"10.3389\/fmed.2022.777443","article-title":"Agreement of Anterior Segment Parameter Measurements With CASIA 2 and IOLMaster 700","volume":"9","author":"Ruan","year":"2022","journal-title":"Front Med (Lausanne)"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/j.jcrs.0000000000000483","article-title":"Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer","volume":"47","author":"Ta\u00f1\u00e1-Rivero","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1186\/s12886-016-0391-1","article-title":"Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery","volume":"16","author":"Sano","year":"2016","journal-title":"BMC Ophthalmol"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1167\/iovs.14-15903","article-title":"An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses","volume":"56","author":"Savini","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib32","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.ajo.2022.02.029","article-title":"Measured Corneal Astigmatism Versus Pseudophakic Predicted Refractive Astigmatism in Cataract Surgery Candidates","volume":"240","author":"Abulafia","year":"2022","journal-title":"Am J Ophthalmol"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2785448","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,16]],"date-time":"2023-03-16T15:31:05Z","timestamp":1678980665000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2785448"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,16]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023,3,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.12.3.13","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2023,3,16]]}}}