{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T12:07:01Z","timestamp":1773403621510,"version":"3.50.1"},"reference-count":39,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"6","license":[{"start":{"date-parts":[[2023,6,28]],"date-time":"2023-06-28T00:00:00Z","timestamp":1687910400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2023,6,28]]},"DOI":"10.1167\/tvst.12.6.19","type":"journal-article","created":{"date-parts":[[2023,6,26]],"date-time":"2023-06-26T14:32:06Z","timestamp":1687789926000},"page":"19","source":"Crossref","is-referenced-by-count":7,"title":["Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma"],"prefix":"10.1167","volume":"12","author":[{"given":"Jonathan","family":"Denniss","sequence":"first","affiliation":[{"name":"School of Optometry and Vision Science, University of Bradford, Bradford, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allison M.","family":"McKendrick","sequence":"additional","affiliation":[{"name":"Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia"},{"name":"Lions Eye Institute, Nedlands, Western Australia, Australia"},{"name":"Optometry, School of Allied Health, University of Western Australia, Perth, Western Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Turpin","sequence":"additional","affiliation":[{"name":"Lions Eye Institute, Nedlands, Western Australia, Australia"},{"name":"Computing & Information Systems, University of Melbourne, Parkville, Victoria, Australia"},{"name":"Curtin School of Population Health, Curtin University, Perth, Western Australia, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"crossref","first-page":"4787","DOI":"10.1167\/iovs.03-0023","article-title":"Properties of perimetric threshold estimates from full threshold, ZEST, and SITA-like strategies, as determined by computer simulation","volume":"43","author":"Turpin","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"bib2","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1167\/tvst.2.4.3","article-title":"Towards patient-tailored perimetry: automated perimetry can be improved by seeding procedures with patient-specific structural information","volume":"2","author":"Denniss","year":"2013","journal-title":"Transl Vis Sci Technol"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"2127","DOI":"10.1016\/j.ophtha.2008.08.013","article-title":"Assessment of patient opinions of different clinical tests used in the management of glaucoma","volume":"115","author":"Gardiner","year":"2008","journal-title":"Ophthalmology"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.ogla.2021.10.003","article-title":"Patients\u2019 views of visual field testing and priorities for research development and translation into practice","volume":"5","author":"Muthusamy","year":"2022","journal-title":"Ophthalmol Glaucoma"},{"key":"bib5","first-page":"2654","article-title":"Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies","volume":"43","author":"Artes","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1016\/j.ophtha.2014.01.020","article-title":"Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage","volume":"121","author":"Gardiner","year":"2014","journal-title":"Ophthalmology"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1136\/bjo.86.7.761","article-title":"Use of high spatial resolution perimetry to identify scotomata not apparent with conventional perimetry in the nasal field of glaucomatous subjects","volume":"86","author":"Westcott","year":"2002","journal-title":"Br J Ophthalmol"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1001\/archopht.121.4.458","article-title":"Increased detection rate of glaucomatous visual field damage with locally condensed grids","volume":"121","author":"Schiefer","year":"2003","journal-title":"Arch Ophthalmol"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"5685","DOI":"10.1167\/iovs.09-5067","article-title":"Spatial pattern of glaucomatous visual field loss obtained with regionally condensed stimulus arrangements","volume":"51","author":"Schiefer","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"e98525","DOI":"10.1371\/journal.pone.0098525","article-title":"Mapping glaucoma patients\u2019 30-2 and 10-2 visual fields reveals clusters of test points damaged in the 10-2 grid that are not sampled in the sparse 30-2 grid","volume":"9","author":"Asaoka","year":"2014","journal-title":"PLoS One"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1097\/IJG.0000000000000460","article-title":"Detectability of visual field defects in glaucoma with high-resolution perimetry","volume":"25","author":"Numata","year":"2016","journal-title":"J Glaucoma"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1016\/j.ophtha.2017.04.021","article-title":"24-2 Visual fields miss central defects shown on 10-2 tests in glaucoma suspects, ocular hypertensives, and early glaucoma","volume":"124","author":"Gustavo De Moraes","year":"2017","journal-title":"Ophthalmology"},{"key":"bib13","first-page":"417","article-title":"Response variability in the visual field: comparison of optic neuritis, glaucoma, ocular hypertension, and normal eyes","volume":"41","author":"Henson","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"6694","DOI":"10.1167\/iovs.12-11185","article-title":"Robust and censored modeling and prediction of progression in glaucomatous visual fields","volume":"54","author":"Bryan","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"2350","DOI":"10.1167\/iovs.13-12492","article-title":"Optimizing structure-function relationship by maximizing correspondence between glaucomatous visual fields and mathematical retinal nerve fiber models","volume":"55","author":"Erler","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"5449","DOI":"10.1167\/iovs.16-20222","article-title":"Spatial interpolation enables normative data comparison in gaze-contingent microperimetry","volume":"57","author":"Denniss","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"2652","DOI":"10.1167\/iovs.16-21086","article-title":"Properties of visual field defects around the monocular preferred retinal locus in age-related macular degeneration","volume":"58","author":"Denniss","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1111\/j.1600-0420.1997.tb00392.x","article-title":"A new generation of algorithms for computerized threshold perimetry, SITA","volume":"75","author":"Bengtsson","year":"1997","journal-title":"Acta Ophthalmol Scand"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1167\/iovs.06-1074","article-title":"Retesting visual fields: utilizing prior information to decrease test\u2013retest variability in glaucoma","volume":"48","author":"Turpin","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1097\/OPX.0000000000000447","article-title":"A perimetric test procedure that uses structural information","volume":"92","author":"Ganeshrao","year":"2015","journal-title":"Optom Vis Sci"},{"key":"bib22","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1034\/j.1600-0420.1998.760303.x","article-title":"Evaluation of a new perimetric strategy, SITA, in patients with manifest and suspect glaucoma","volume":"76","author":"Bengtsson","year":"1998","journal-title":"Acta Ophthalmol Scand"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1034\/j.1600-0420.1998.760208.x","article-title":"Evaluation of a new threshold visual field strategy, SITA, in normal subjects","volume":"76","author":"Bengtsson","year":"1998","journal-title":"Acta Ophthalmol Scand"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1167\/tvst.5.2.7","article-title":"Incorporating spatial models in visual field test procedures","volume":"5","author":"Rubinstein","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1097\/01.opx.0000187841.08676.36","article-title":"Advantages of terminating Zippy Estimation by Sequential Testing (ZEST) with dynamic criteria for white-on-white perimetry","volume":"82","author":"McKendrick","year":"2005","journal-title":"Optom Vis Sci"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.visres.2014.04.013","article-title":"Response times across the visual field: empirical observations and application to threshold determination","volume":"101","author":"McKendrick","year":"2014","journal-title":"Vision Res"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"5985","DOI":"10.1167\/iovs.12-10428","article-title":"The relationship between variability and sensitivity in large-scale longitudinal visual field data","volume":"53","author":"Russell","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1167\/tvst.10.1.18","article-title":"Effects of criterion bias on perimetric sensitivity and response variability in glaucoma","volume":"10","author":"Rubinstein","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/S0161-6420(01)00948-4","article-title":"Baseline visual field characteristics in the ocular hypertension treatment study","volume":"109","author":"Johnson","year":"2002","journal-title":"Ophthalmology"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"e41211","DOI":"10.1371\/journal.pone.0041211","article-title":"Persistence, spatial distribution and implications for progression detection of blind parts of the visual field in glaucoma: a clinical cohort study","volume":"7","author":"Junoy Montolio","year":"2012","journal-title":"PLoS One"},{"key":"bib32","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1167\/iovs.15-18000","article-title":"The effect of limiting the range of perimetric sensitivities on pointwise assessment of visual field progression in glaucoma","volume":"57","author":"Gardiner","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib33","first-page":"268","article-title":"Fatigue effects during a single session of automated static threshold perimetry","volume":"35","author":"Hudson","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1167\/tvst.5.5.1","article-title":"Assessing the GOANNA visual field algorithm using artificial scotoma generation on human observers","volume":"5","author":"Chong","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"bib35","doi-asserted-by":"publisher","first-page":"3265","DOI":"10.1167\/iovs.13-13761","article-title":"Customized, automated stimulus location choice for assessment of visual field defects","volume":"55","author":"Chong","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib36","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1167\/tvst.7.5.35","article-title":"Improving spatial resolution and test times of visual field testing using ARREST","volume":"7","author":"Turpin","year":"2018","journal-title":"Transl Vis Sci Technol"},{"key":"bib37","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1167\/tvst.9.13.24","article-title":"Increasing the spatial resolution of visual field tests without increasing test duration: an evaluation of ARREST","volume":"9","author":"Muthusamy","year":"2020","journal-title":"Transl Vis Sci Technol"},{"key":"bib38","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1046\/j.1475-1313.2002.00055.x","article-title":"New developments in supra-threshold perimetry","volume":"22","author":"Henson","year":"2002","journal-title":"Ophthalmic Physiol Opt"},{"key":"bib39","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.ajo.2018.10.010","article-title":"A new SITA perimetric threshold testing algorithm: construction and a new multicenter clinical study","volume":"198","author":"Heijl","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"bib16","article-title":"Longitudinal glaucomatous visual field data","author":"Rotterdam Ophthalmic Data Repository"},{"key":"bib30","volume-title":"R: A language and environment for statistical computing","author":"R Core Team","year":"2022"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2785727","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,28]],"date-time":"2023-06-28T20:30:53Z","timestamp":1687984253000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2785727"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,28]]},"references-count":39,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023,6,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.12.6.19","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6,28]]}}}