{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T13:24:37Z","timestamp":1788269077575,"version":"build-2803163510"},"reference-count":27,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"2","license":[{"start":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T00:00:00Z","timestamp":1708905600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2024,2,26]]},"DOI":"10.1167\/tvst.13.2.19","type":"journal-article","created":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T16:31:05Z","timestamp":1708965065000},"page":"19","source":"Crossref","is-referenced-by-count":12,"title":["Effect of Decentration, Rotation, and Tilt on Objective Optical Quality of Plate Haptic Toric Intraocular Lenses in the Early Postoperative Period"],"prefix":"10.1167","volume":"13","author":[{"given":"Yingying","family":"Hong","sequence":"first","affiliation":[{"name":"Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China"},{"name":"NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China"},{"name":"Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Sun","sequence":"additional","affiliation":[{"name":"Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China"},{"name":"NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China"},{"name":"Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Houyi","family":"Liu","sequence":"additional","affiliation":[{"name":"Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yinghong","family":"Ji","sequence":"additional","affiliation":[{"name":"Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China"},{"name":"NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China"},{"name":"Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China"},{"name":"https:\/\/orcid.org\/0000-0003-3340-5373"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"issue":"1","key":"bib1","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.jcrs.2008.09.027","article-title":"Prevalence of corneal astigmatism before cataract surgery","volume":"35","author":"Ferrer-Blasco","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"bib2","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","article-title":"Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes","volume":"36","author":"Hoffmann","year":"2010","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"bib3","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1136\/bjophthalmol-2015-306656","article-title":"Factors influencing 1-year rotational stability of AcrySof Toric intraocular lenses","volume":"100","author":"Zhu","year":"2016","journal-title":"Br J Ophthalmol"},{"issue":"5","key":"bib4","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/S0886-3350(13)80232-5","article-title":"Toric intraocular lenses: correcting astigmatism while controlling axis shift","volume":"20","author":"Shimizu","year":"1994","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"bib5","doi-asserted-by":"publisher","first-page":"194","DOI":"10.3928\/1081597X-20130129-02","article-title":"Efficacy and stability of AT TORBI 709 M toric IOL","volume":"29","author":"Bascaran","year":"2013","journal-title":"J Refract Surg"},{"issue":"2","key":"bib6","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.jcrs.2010.08.049","article-title":"Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens","volume":"37","author":"Prinz","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"bib7","doi-asserted-by":"publisher","first-page":"1353","DOI":"10.1097\/j.jcrs.0000000000000259","article-title":"Comparison of the rotational stability between plate-haptic toric and C-loop haptic toric IOLs in myopic eyes","volume":"46","author":"Zhu","year":"2020","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"bib8","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1097\/j.jcrs.0000000000000273","article-title":"Residual astigmatism with toric intraocular lens misalignment","volume":"46","author":"Holladay","year":"2020","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"bib9","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.jcrs.2017.10.053","article-title":"Quality of images with toric intraocular lenses","volume":"44","author":"Tognetto","year":"2018","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"bib10","doi-asserted-by":"publisher","first-page":"2274","DOI":"10.1016\/j.jcrs.2015.10.059","article-title":"Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: influence of pupil size, decentration, and rotation","volume":"41","author":"Kim","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"bib11","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1007\/s00417-014-2629-z","article-title":"Optical quality of aspheric toric intraocular lenses at different degrees of decentering","volume":"252","author":"Perez-Vives","year":"2014","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"4","key":"bib12","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1364\/BOE.447045","article-title":"Effect of decentration, tilt and rotation on the optical quality of various toric intraocular lens designs: a numerical and experimental study","volume":"13","author":"P\u00e9rez-Gracia","year":"2022","journal-title":"Biomed Opt Express"},{"issue":"4","key":"bib13","first-page":"730","article-title":"Optical performance of toric intraocular lenses in the presence of decentration","volume":"8","author":"Zhang","year":"2015","journal-title":"Int J Ophthalmol"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ajo.2018.01.007","article-title":"Inferior decentration of multifocal intraocular lenses in myopic eyes","volume":"188","author":"Zhu","year":"2018","journal-title":"Am J Ophthalmol"},{"issue":"6","key":"bib15","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.jcrs.2009.01.023","article-title":"Tilt and decentration of spherical and aspheric intraocular lenses: effect on higher-order aberrations","volume":"35","author":"Baumeister","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"bib16","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/S0886-3350(99)80019-4","article-title":"Computer modeling of visual impairment caused by intraocular lens misalignment","volume":"25","author":"Korynta","year":"1999","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"bib17","doi-asserted-by":"publisher","first-page":"1684","DOI":"10.1016\/S0886-3350(03)00523-6","article-title":"Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses. Prospective evaluation","volume":"29","author":"Kershner","year":"2003","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"bib18","doi-asserted-by":"publisher","first-page":"1841","DOI":"10.1364\/JOSAA.20.001841","article-title":"Optical aberrations of intraocular lenses measured in vivo and in vitro","volume":"20","author":"Barbero","year":"2003","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"issue":"10","key":"bib19","doi-asserted-by":"publisher","first-page":"2158","DOI":"10.1016\/j.jcrs.2004.02.072","article-title":"Influence of intraocular lens tilt and decentration on wavefront aberrations","volume":"30","author":"Taketani","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"bib20","doi-asserted-by":"publisher","first-page":"484","DOI":"10.3928\/1081597X-20190708-02","article-title":"Effect of decentration on the optical quality of monofocal, extended depth of focus, and bifocal intraocular lenses","volume":"35","author":"Xu","year":"2019","journal-title":"J Refract Surg"},{"issue":"6","key":"bib21","doi-asserted-by":"publisher","first-page":"389","DOI":"10.3928\/1081597X-20170329-01","article-title":"A new extended depth of focus intraocular lens based on spherical aberration","volume":"33","author":"Bellucci","year":"2017","journal-title":"J Refract Surg"},{"issue":"12","key":"bib22","doi-asserted-by":"publisher","first-page":"808","DOI":"10.3928\/1081597X-20171004-02","article-title":"Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens","volume":"33","author":"Tandogan","year":"2017","journal-title":"J Refract Surg"},{"issue":"5","key":"bib23","doi-asserted-by":"publisher","first-page":"e0232546","DOI":"10.1371\/journal.pone.0232546","article-title":"Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors","volume":"15","author":"P\u00e9rez-Gracia","year":"2020","journal-title":"PLoS One"},{"issue":"4","key":"bib24","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1364\/BOE.447045","article-title":"Effect of decentration, tilt and rotation on the optical quality of various toric intraocular lens designs: a numerical and experimental study","volume":"13","author":"P\u00e9rez-Gracia","year":"2022","journal-title":"Biomed Opt Express"},{"issue":"1","key":"bib25","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1177\/11206721211002121","article-title":"Effect of defocus combined with rotation on the optical performance of trifocal toric IOLs","volume":"32","author":"Ruiz-Alcocer","year":"2022","journal-title":"Eur J Ophthalmol"},{"issue":"5","key":"bib26","doi-asserted-by":"publisher","first-page":"335","DOI":"10.3928\/1081597X-20120321-01","article-title":"Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt","volume":"28","author":"Felipe","year":"2012","journal-title":"J Refract Surg"},{"issue":"14","key":"bib27","doi-asserted-by":"publisher","first-page":"850","DOI":"10.21037\/atm","article-title":"Profiles of intraocular higher-order aberrations in healthy phakic eyes: prospective cross-sectional study","volume":"8","author":"Zhang","year":"2020","journal-title":"Ann Transl Med"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2793401","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T16:31:11Z","timestamp":1708965071000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2793401"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,26]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.13.2.19","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2,26]]}}}