{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T04:14:33Z","timestamp":1751429673238,"version":"3.41.0"},"reference-count":36,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"7","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2025,7,1]]},"DOI":"10.1167\/tvst.14.7.3","type":"journal-article","created":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T14:47:07Z","timestamp":1751381227000},"page":"3","source":"Crossref","is-referenced-by-count":0,"title":["A Method to Evaluate the Frequency Dependence of Retinal Vascular and Neural Metrics to Stimulus Modulation"],"prefix":"10.1167","volume":"14","author":[{"given":"Anthony E.","family":"Felder","sequence":"first","affiliation":[{"name":"Richard and Loan Hill Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giri","family":"Balasubramanian","sequence":"additional","affiliation":[{"name":"Richard and Loan Hill Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL, USA"},{"name":"Ophthalmology and Visual Sciences, University of Illinois Chicago, Chicago, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aldo","family":"Arroyo","sequence":"additional","affiliation":[{"name":"Richard and Loan Hill Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason C.","family":"Park","sequence":"additional","affiliation":[{"name":"Ophthalmology and Visual Sciences, University of Illinois Chicago, Chicago, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahnaz","family":"Shahidi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA"},{"name":"Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. Jason","family":"McAnany","sequence":"additional","affiliation":[{"name":"Richard and Loan Hill Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL, USA"},{"name":"Ophthalmology and Visual Sciences, University of Illinois Chicago, Chicago, IL, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.preteyeres.2004.08.001","article-title":"Retinal oxygenation response and retinopathy","volume":"24","author":"Trick","year":"2005","journal-title":"Prog Retin Eye Res"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.preteyeres.2012.04.004","article-title":"Cellular and physiological mechanisms underlying blood flow regulation in the retina and choroid in health and disease","volume":"31","author":"Kur","year":"2012","journal-title":"Prog Retin Eye Res"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"1685","DOI":"10.1038\/jcbfm.2013.145","article-title":"Functional hyperemia and mechanisms of neurovascular coupling in the retinal vasculature","volume":"33","author":"Newman","year":"2013","journal-title":"J Cerebr Blood Flow Metab"},{"key":"bib4","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1076\/ceyr.24.2.109.8164","article-title":"Influence of diffuse luminance flicker on choroidal and optic nerve head blood flow","volume":"24","author":"Garhofer","year":"2002","journal-title":"Curr Eye Res"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1016\/j.visres.2003.11.013","article-title":"Diffuse luminance flicker increases blood flow in major retinal arteries and veins","volume":"44","author":"Garhofer","year":"2004","journal-title":"Vision Res"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1167\/iovs.10-5537","article-title":"Retinal venous oxygen saturation increases by flicker light stimulation","volume":"52","author":"Hammer","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1076\/ceyr.16.12.1252.5021","article-title":"Diffuse luminance flicker increases retinal vessel diameter in humans","volume":"16","author":"Formaz","year":"1997","journal-title":"Curr Eye Res"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1136\/bjo.88.1.54","article-title":"Flicker observation light induces diameter response in retinal arterioles: a clinical methodological study","volume":"88","author":"Nagel","year":"2004","journal-title":"Br J Ophthalmol"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1111\/j.1755-3768.2009.01587.x","article-title":"Use of the retinal vessel analyzer in ocular blood flow research","volume":"88","author":"Garhofer","year":"2010","journal-title":"Acta Ophthalmol"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"e0207525","DOI":"10.1371\/journal.pone.0207525","article-title":"Evaluation of flicker induced hyperemia in the retina and optic nerve head measured by laser speckle flowgraphy","volume":"13","author":"Fondi","year":"2018","journal-title":"PLoS One"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"5666","DOI":"10.1167\/iovs.17-22174","article-title":"Retinal vascular and oxygen temporal dynamic responses to light flicker in humans","volume":"58","author":"Felder","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1167\/iovs.16-20598","article-title":"Effect of diffuse luminance flicker light stimulation on total retinal blood flow assessed with dual-beam bidirectional Doppler OCT","volume":"58","author":"Aschinger","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"e0162621","DOI":"10.1371\/journal.pone.0162621","article-title":"Evidence of flicker-induced functional hyperaemia in the smallest vessels of the human retinal blood supply","volume":"11","author":"Duan","year":"2016","journal-title":"PLoS One"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"6633","DOI":"10.1167\/iovs.15-17321","article-title":"Inner retinal oxygen extraction fraction in response to light flicker stimulation in humans","volume":"56","author":"Felder","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"18291","DOI":"10.1038\/srep18291","article-title":"Relation of retinal blood flow and retinal oxygen extraction during stimulation with diffuse luminance flicker","volume":"5","author":"Palkovits","year":"2015","journal-title":"Sci Rep"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"5586","DOI":"10.1167\/iovs.16-20048","article-title":"The effects of diabetic retinopathy stage and light flicker on inner retinal oxygen extraction fraction","volume":"57","author":"Felder","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib17","first-page":"2721","article-title":"Influence of flicker frequency on flicker-induced changes of retinal vessel diameter","volume":"43","author":"Polak","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib18","first-page":"2309","article-title":"Flicker-evoked changes in human optic nerve blood flow: relationship with retinal neural activity","volume":"43","author":"Falsini","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib19","first-page":"756","article-title":"Flicker-evoked responses of human optic nerve head blood flow: Luminance versus chromatic modulation","volume":"42","author":"Riva","year":"2001","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/j.preteyeres.2004.07.002","article-title":"Visually evoked hemodynamical response and assessment of neurovascular coupling in the optic nerve and retina","volume":"24","author":"Riva","year":"2005","journal-title":"Prog Retin Eye Res"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1113\/jphysiol.1995.sp020509","article-title":"Variations of blood flow at optic nerve head induced by sinusoidal flicker stimulation in cats","volume":"482","author":"Vo Van","year":"1995","journal-title":"J Physiol"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"4962","DOI":"10.1167\/iovs.06-0291","article-title":"Chorioretinal vascular oxygen tension changes in response to light flicker","volume":"47","author":"Shakoor","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib23","first-page":"2216","article-title":"Frequency and luminance-dependent blood flow and K+ ion changes during flicker stimuli in cat optic nerve head","volume":"36","author":"Buerk","year":"1995","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"1633","DOI":"10.1093\/clinchem\/37.9.1633","article-title":"Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin","volume":"37","author":"Zijlstra","year":"1991","journal-title":"Clin Chem"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"6659","DOI":"10.1038\/s41598-024-57263-z","article-title":"Stimulus type and duration affect magnitude and evolution of flicker-induced hyperemia measured by laser speckle flowgraphy at the optic disc and peripapillary vessels","volume":"14","author":"Aung","year":"2024","journal-title":"Sci Rep"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"054015","DOI":"10.1117\/1.2976032","article-title":"Retinal vessel oximetry-calibration, compensation for vessel diameter and fundus pigmentation, and reproducibility","volume":"13","author":"Hammer","year":"2008","journal-title":"J Biomed Opt"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"3120","DOI":"10.1167\/iovs.13-13255","article-title":"Retinal oximetry with a scanning laser ophthalmoscope","volume":"55","author":"Kristjansdottir","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s10633-024-09970-1","article-title":"ISCEV standard for clinical pattern electroretinography (2024 update)","volume":"148","author":"Thompson","year":"2024","journal-title":"Doc Ophthalmol"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/s004170050201","article-title":"The contrast characteristic of the pattern electroretinogram depends on temporal frequency","volume":"237","author":"Zapf","year":"1999","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1023\/A:1002097208337","article-title":"On the statistical significance of electrophysiological steady-state responses","volume":"98","author":"Meigen","year":"1999","journal-title":"Doc Ophthalmol"},{"key":"bib32","doi-asserted-by":"publisher","first-page":"19796","DOI":"10.1038\/s41598-020-75296-y","article-title":"Longitudinal stability of retinal blood flow regulation in response to flicker stimulation and systemic hyperoxia in mice assessed with laser speckle flowgraphy","volume":"10","author":"Hanaguri","year":"2020","journal-title":"Sci Rep"},{"key":"bib33","doi-asserted-by":"publisher","first-page":"6055","DOI":"10.1167\/iovs.13-13811","article-title":"Response of inner retinal oxygen extraction fraction to light flicker under normoxia and hypoxia in rat","volume":"55","author":"Teng","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib34","doi-asserted-by":"publisher","first-page":"10731","DOI":"10.1038\/srep10731","article-title":"Electroretinographic assessment of rod- and cone-mediated bipolar cell pathways using flicker stimuli in mice","volume":"5","author":"Tanimoto","year":"2015","journal-title":"Sci Rep"},{"key":"bib35","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1016\/j.tins.2006.08.004","article-title":"Astrocytic complexity distinguishes the human brain","volume":"29","author":"Oberheim","year":"2006","journal-title":"Trends Neurosci"},{"key":"bib36","doi-asserted-by":"publisher","first-page":"e1489","DOI":"10.1111\/aos.15189","article-title":"Correlation between retinal oxygen saturation and the haemodynamic parameters of the ophthalmic artery in healthy subjects","volume":"100","author":"Kral","year":"2022","journal-title":"Acta Ophthalmol"},{"key":"bib26","first-page":"130","article-title":"Multiscale vessel enhancement filtering","volume-title":"Medical Image Computing and Computer-Assisted Intervention\u2014MICAI\u201998","author":"Frangi","year":"1998"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2803198","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T14:47:09Z","timestamp":1751381229000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2803198"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,1]]},"references-count":36,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.14.7.3","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2025,7,1]]}}}