{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:59:13Z","timestamp":1791295153985,"version":"4.1.0"},"reference-count":36,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"10","license":[{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2026,10,6]]},"DOI":"10.1167\/tvst.15.10.5","type":"journal-article","created":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:30:36Z","timestamp":1791293436000},"page":"5","source":"Crossref","is-referenced-by-count":0,"title":["Axial Length\u2013Adjusted Normative Reference Values for Retinal Layer Thickness in a Population-Based OCT Study"],"prefix":"10.1167","volume":"15","author":[{"given":"Mi Yeon","family":"Song","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Sensory Organ Research Institute, Dongguk University Ilsan Hospital, Goyang, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min Seong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingui","family":"Kong","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1016\/j.ophtha.2011.10.010","article-title":"Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a prospective analysis of age-related loss","volume":"119","author":"Leung","year":"2012","journal-title":"Ophthalmology"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"7872","DOI":"10.1167\/iovs.11-7896","article-title":"Profile and predictors of normal ganglion cell-inner plexiform layer thickness measured with frequency-domain optical coherence tomography","volume":"52","author":"Mwanza","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"4934","DOI":"10.1167\/iovs.13-11913","article-title":"Effect of age on individual retinal layer thickness in normal eyes as measured with spectral-domain optical coherence tomography","volume":"54","author":"Demirkaya","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"suppl 2","key":"bib4","doi-asserted-by":"publisher","first-page":"ii1","DOI":"10.1136\/bjophthalmol-2014-305156","article-title":"On improving the use of OCT imaging for detecting glaucomatous damage","volume":"98","author":"Hood","year":"2014","journal-title":"Br J Ophthalmol"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1001\/archopthalmol.2011.1576","article-title":"Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT","volume":"130","author":"Knight","year":"2012","journal-title":"Arch Ophthalmol"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"5171","DOI":"10.1167\/iovs.06-0545","article-title":"Retinal nerve fiber layer measurements in myopia: an optical coherence tomography study","volume":"47","author":"Leung","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1097\/IJG.0b013e318193c2be","article-title":"Myopia affects retinal nerve fiber layer measurements as determined by optical coherence tomography","volume":"18","author":"Rauscher","year":"2009","journal-title":"J Glaucoma"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1136\/bjo.2010.196782","article-title":"The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT","volume":"96","author":"Savini","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"1739","DOI":"10.1016\/S0140-6736(12)60272-4","volume":"379","author":"Morgan","year":"2012","journal-title":"Lancet"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1136\/bjophthalmol-2017-310869","article-title":"Macular imaging by optical coherence tomography in the diagnosis and management of glaucoma","volume":"102","author":"Kim","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"1558","DOI":"10.1016\/j.ophtha.2011.01.026","article-title":"Evaluation of retinal nerve fiber layer progression in glaucoma: a comparison between spectral-domain and time-domain optical coherence tomography","volume":"118","author":"Leung","year":"2011","journal-title":"Ophthalmology"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1093\/ije\/dyt228","article-title":"Data resource profile: the Korea National Health and Nutrition Examination Survey (KNHANES)","volume":"43","author":"Kweon","year":"2014","journal-title":"Int J Epidemiol"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"295","DOI":"10.3341\/kjo.2021.0016","article-title":"Methodology and rationale for ophthalmic examinations in the seventh and eighth Korea National Health and Nutrition Examination Surveys (2017-2021)","volume":"35","author":"Song","year":"2021","journal-title":"Korean J Ophthalmol"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.preteyeres.2017.09.004","article-title":"The epidemics of myopia: aetiology and prevention","volume":"62","author":"Morgan","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"4075","DOI":"10.1167\/iovs.09-4737","article-title":"Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography","volume":"51","author":"Kang","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/j.ajo.2011.04.002","article-title":"Diagnostic classification of retinal nerve fiber layer measurement in myopic eyes: a comparison between time-domain and spectral-domain optical coherence tomography","volume":"152","author":"Qiu","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s12886-017-0419-1","article-title":"Ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis","volume":"17","author":"Seo","year":"2017","journal-title":"BMC Ophthalmol"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1038\/s41433-020-0847-7","article-title":"Evaluation of the association of macular ganglion cell-inner plexiform layer thickness and myopia in Chinese young adults","volume":"35","author":"Lu","year":"2021","journal-title":"Eye (Lond)"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1016\/j.oret.2017.12.012","article-title":"Normative data for retinal-layer thickness maps generated by spectral-domain OCT in a white population","volume":"2","author":"Invernizzi","year":"2018","journal-title":"Ophthalmol Retina"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1016\/j.ophtha.2006.02.067","article-title":"Peripapillary retinal nerve fiber layer thickness in a population of 6-year-old children: findings by optical coherence tomography","volume":"113","author":"Huynh","year":"2006","journal-title":"Ophthalmology"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.ophtha.2018.11.031","article-title":"Retinal nerve fiber layer thickness in a multiethnic normal Asian population: the Singapore Epidemiology of Eye Diseases Study","volume":"126","author":"Ho","year":"2019","journal-title":"Ophthalmology"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1038\/eye.2012.216","article-title":"Retinal nerve fiber layer and optic disc measurements by spectral domain OCT: normative values and associations in young adults","volume":"26","author":"Tariq","year":"2012","journal-title":"Eye (Lond)"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"9629","DOI":"10.1167\/iovs.11-7481","article-title":"Determinants of quantitative optic nerve measurements using spectral domain optical coherence tomography in a population-based sample of non-glaucomatous subjects","volume":"52","author":"Cheung","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1136\/bjophthalmol-2018-313159","article-title":"Normative pattern and determinants of outer retinal thickness in an Asian population: the Singapore Epidemiology of Eye Diseases Study","volume":"103","author":"Dai","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1136\/bjo.2007.127571","article-title":"Peripapillary retinal nerve fibre layer thickness in highly myopic Caucasians as measured by Stratus optical coherence tomography","volume":"92","author":"Vernon","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1001\/jamaophthalmol.2016.2343","article-title":"Evaluation of a myopic normative database for analysis of retinal nerve fiber layer thickness","volume":"134","author":"Biswas","year":"2016","journal-title":"JAMA Ophthalmol"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"5856","DOI":"10.1167\/iovs.16-20116","article-title":"Glaucoma-diagnostic ability of ganglion cell-inner plexiform layer thickness difference across temporal raphe in highly myopic eyes","volume":"57","author":"Kim","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib30","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.ajo.2020.09.039","article-title":"Longitudinal macular ganglion cell-inner plexiform layer measurements to detect glaucoma progression in high myopia","volume":"223","author":"Shin","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"bib31","doi-asserted-by":"publisher","first-page":"469","DOI":"10.3341\/kjo.2020.0012","article-title":"Comparison of retinal layer thicknesses of highly myopic eyes and normal eyes","volume":"34","author":"Kim","year":"2020","journal-title":"Korean J Ophthalmol"},{"key":"bib32","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1167\/iovs.15-18529","article-title":"Retinal thickness and axial length","volume":"57","author":"Jonas","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib33","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/j.ophtha.2006.01.058","article-title":"Peripapillary retinal nerve fiber layer thickness variations with myopia","volume":"113","author":"Hoh","year":"2006","journal-title":"Ophthalmology"},{"key":"bib34","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1097\/JCMA.0000000000000254","article-title":"Glaucoma assessment in high myopic eyes using optical coherence tomography with long axial length normative database","volume":"83","author":"Chang","year":"2020","journal-title":"J Chin Med Assoc"},{"key":"bib35","doi-asserted-by":"publisher","first-page":"100120","DOI":"10.1016\/j.xops.2022.100120","article-title":"Structure-function relationships and glaucoma detection with magnification correction of OCT angiography","volume":"2","author":"Hirasawa","year":"2022","journal-title":"Ophthalmol Sci"},{"key":"bib36","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.18240\/ijo.2025.06.15","article-title":"Comparison of axial length measurements with RS-1 spectral domain optical coherence tomography and OA-2000 biometer","volume":"18","author":"Fujihara","year":"2025","journal-title":"Int J Ophthalmol"},{"key":"bib15","volume-title":"Korea National Health and Nutrition Examination Survey (KNHANES) VII (2016\u20132018) Codebook","author":"Korea Disease Control and Prevention Agency","year":"2019"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/tvst.arvojournals.org\/article.aspx?doi=10.1167\/tvst.15.10.5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:30:37Z","timestamp":1791293437000},"score":1,"resource":{"primary":{"URL":"http:\/\/tvst.arvojournals.org\/article.aspx?doi=10.1167\/tvst.15.10.5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,6]]},"references-count":36,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10,5]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.15.10.5","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10,6]]}}}