{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T14:00:33Z","timestamp":1790776833259,"version":"4.1.0"},"reference-count":29,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"9","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2026,9,30]]},"DOI":"10.1167\/tvst.15.9.24","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:30:45Z","timestamp":1790775045000},"page":"24","source":"Crossref","is-referenced-by-count":0,"title":["Noninterchangeability of Vessel Density Measurements Across Next-Generation SS-OCTA Systems"],"prefix":"10.1167","volume":"15","author":[{"given":"Peter M.","family":"Maloca","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"},{"name":"Moorfields Eye Hospital NHS Foundation Trust, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe C.","family":"Cattin","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nadja","family":"Inglin","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudia","family":"Bru\u00e8","sequence":"additional","affiliation":[{"name":"Ophthalmic clinic, Macerata Hospital, Macerata, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascal W.","family":"Hasler","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Rothenbuehler","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanna","family":"Zuche","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Zarranz-Ventura","sequence":"additional","affiliation":[{"name":"Institut Cl\u00ednic de Oftalmologia (ICOF), Hospital Cl\u00ednic de Barcelona, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Valmaggia","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland"},{"name":"Department of Ophthalmology, University Hospital Basel, Basel, Switzerland"},{"name":"Moorfields Eye Hospital NHS Foundation Trust, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","article-title":"Optical coherence tomography angiography","volume":"64","author":"Spaide","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"bib2","doi-asserted-by":"crossref","first-page":"E2395","DOI":"10.1073\/pnas.1500185112","article-title":"Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye","volume":"112","author":"Jia","year":"2015","journal-title":"Proc Natl Acad Sci USA"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1016\/j.survophthal.2017.05.006","article-title":"The application of optical coherence tomography angiography in retinal diseases","volume":"62","author":"Sambhav","year":"2017","journal-title":"Surv Ophthalmol"},{"key":"bib4","doi-asserted-by":"crossref","first-page":"3723","DOI":"10.1167\/iovs.15-19043","article-title":"Optical coherence tomography angiography","volume":"57","author":"Gao","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"28997","DOI":"10.1038\/s41598-024-80562-4","article-title":"Scan speed affects quantitative optical coherence tomography angiography vascular metrics","volume":"14","author":"Vidal-Oliver","year":"2024","journal-title":"Sci Rep"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"1438739","DOI":"10.3389\/fendo.2025.1438739","article-title":"Recent advances and applications of optical coherence tomography angiography in diabetic retinopathy","volume":"16","author":"Zhang","year":"2025","journal-title":"Front Endocrinol (Lausanne)"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1097\/IAE.0000000000004751","article-title":"Comparison of ultra-high speed 250 kHz OCTA with high speed 125 kHz mode using Heidelberg Spectralis SHIFT: a paired-eye analysis","volume":"46","author":"Morsy","year":"2025","journal-title":"Retina"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.1364\/OL.43.002237","article-title":"Wide dynamic range high-speed three-dimensional quantitative OCT angiography with a hybrid-beam scan","volume":"43","author":"Park","year":"2018","journal-title":"Opt Lett"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.1007\/s00417-020-04945-9","article-title":"A quantitative comparison of four optical coherence tomography angiography devices in healthy eyes","volume":"259","author":"Lu","year":"2021","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"20129","DOI":"10.1038\/s41598-025-04650-9","article-title":"Quantitative comparison of a novel swept-source optical coherence tomography angiography device with three established systems","volume":"15","author":"Hafner","year":"2025","journal-title":"Sci Rep"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"8345","DOI":"10.1038\/s41598-020-65243-2","article-title":"Agreement in measures of macular perfusion between optical coherence tomography angiography machines","volume":"10","author":"Dai","year":"2020","journal-title":"Sci Rep"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"774","DOI":"10.3390\/s24030774","article-title":"Segmentation of low-light optical coherence tomography angiography images under the constraints of vascular network topology","volume":"24","author":"Li","year":"2024","journal-title":"Sensors (Basel)"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"4429","DOI":"10.1364\/BOE.9.004429","article-title":"Automated segmentation of retinal layer boundaries and capillary plexuses in wide-field optical coherence tomographic angiography","volume":"9","author":"Guo","year":"2018","journal-title":"Biomed Opt Express"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"21485","DOI":"10.1038\/s41598-021-00826-1","article-title":"Distance between the center of the FAZ measured automatically and the highest foveal bulge using OCT-angiography in elderly healthy eyes","volume":"11","author":"Shoji","year":"2021","journal-title":"Sci Rep"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/j.ajo.2024.09.012","article-title":"A comparison of optical coherence tomography angiography metrics and artifacts on scans of different sizes in diabetic macular ischemia","volume":"269","author":"Tsai","year":"2025","journal-title":"Am J Ophthalmol"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1001\/jamaophthalmol.2019.4971","article-title":"Prevalence and severity of artifacts in optical coherence tomographic angiograms","volume":"138","author":"Holmen","year":"2020","journal-title":"JAMA Ophthalmol"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1016\/j.survophthal.2024.03.004","article-title":"Optical coherence tomography angiography in diabetic retinopathy: a major review","volume":"69","author":"Nouri","year":"2024","journal-title":"Surv Ophthalmol"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.preteyeres.2017.07.002","article-title":"Optical coherence tomography angiography: a comprehensive review of current methods and clinical applications","volume":"60","author":"Kashani","year":"2017","journal-title":"Prog Retin Eye Res"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"100695","DOI":"10.1016\/j.xops.2024.100695","article-title":"Quantitative mapping of posterior eye curvature in children using distortion-corrected OCT: insights into temporal region morphology","volume":"5","author":"Hiraoka","year":"2025","journal-title":"Ophthalmol Sci"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.1038\/s41598-025-32549-y","article-title":"Impact of 85 kHz versus 125 kHz SHIFT OCTA scan speeds on image quality in retinal diseases and diagnostic reliability of choroidal neovascular membranes","volume":"16","author":"Tran","year":"2025","journal-title":"Sci Rep"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/j.oret.2017.08.013","article-title":"Analyzing relative blood flow speeds in choroidal neovascularization using variable interscan time analysis OCT angiography","volume":"2","author":"Rebhun","year":"2018","journal-title":"Ophthalmol Retina"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1167\/iovs.65.6.9","article-title":"Time-resolved dynamic optical coherence tomography for retinal blood flow analysis","volume":"65","author":"Valmaggia","year":"2024","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1007\/s00417-019-04553-2","article-title":"Optical coherence tomography angiography-derived flow density: a review of the influencing factors","volume":"258","author":"Br\u00fccher","year":"2020","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"e0261052","DOI":"10.1371\/journal.pone.0261052","article-title":"OCTAVA: an open-source toolbox for quantitative analysis of optical coherence tomography angiography images","volume":"16","author":"Untracht","year":"2021","journal-title":"PLoS One"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"379","DOI":"10.3758\/BF03195514","article-title":"Beyond the five-user assumption: benefits of increased sample sizes in usability testing","volume":"35","author":"Faulkner","year":"2003","journal-title":"Behav Res Methods Instrum Comput"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"17866","DOI":"10.1038\/s41598-018-36279-2","article-title":"Repeatability and reproducibility of quantification of superficial peri-papillary capillaries by four different optical coherence tomography angiography devices","volume":"8","author":"Lei","year":"2018","journal-title":"Sci Rep"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"e0206045","DOI":"10.1371\/journal.pone.0206045","article-title":"Repeatability, reproducibility and agreement of foveal avascular zone measurements using three different optical coherence tomography angiography devices","volume":"13","author":"Mihailovic","year":"2018","journal-title":"PLoS One"},{"key":"bib28","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1136\/bjophthalmol-2015-307330","article-title":"Reproducibility and repeatability of foveal avascular zone measurements in healthy subjects by optical coherence tomography angiography","volume":"100","author":"Carpineto","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"bib29","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1001\/jamaophthalmol.2019.4821","article-title":"Assessing the use of incorrectly scaled optical coherence tomography angiography images in peer-reviewed studies: a systematic review","volume":"138","author":"Llanas","year":"2020","journal-title":"JAMA Ophthalmol"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/tvst.arvojournals.org\/article.aspx?doi=10.1167\/tvst.15.9.24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:30:46Z","timestamp":1790775046000},"score":1,"resource":{"primary":{"URL":"http:\/\/tvst.arvojournals.org\/article.aspx?doi=10.1167\/tvst.15.9.24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":29,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.15.9.24","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9,30]]}}}