{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T05:09:40Z","timestamp":1779340180733,"version":"3.51.4"},"reference-count":43,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"13","license":[{"start":{"date-parts":[[2020,12,18]],"date-time":"2020-12-18T00:00:00Z","timestamp":1608249600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2020,12,18]]},"DOI":"10.1167\/tvst.9.13.30","type":"journal-article","created":{"date-parts":[[2020,12,19]],"date-time":"2020-12-19T05:39:31Z","timestamp":1608356371000},"page":"30","source":"Crossref","is-referenced-by-count":42,"title":["Classification of Color-Coded Scheimpflug Camera Corneal Tomography Images Using Deep Learning"],"prefix":"10.1167","volume":"9","author":[{"given":"Hazem","family":"Abdelmotaal","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Assiut University, Assiut, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magdi M.","family":"Mostafa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Assiut University, Assiut, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali N. R.","family":"Mostafa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Assiut University, Assiut, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdelsalam A.","family":"Mohamed","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Assiut University, Assiut, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Khaled","family":"Abdelazeem","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Assiut University, Assiut, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27","reference":[{"issue":"4","key":"bib1","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv Ophthalmol"},{"issue":"12","key":"bib2","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1016\/j.jcrs.2012.10.022","article-title":"Characterization of corneal structure in keratoconus","volume":"38","author":"Pi\u00f1ero","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"bib3","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1097\/ICL.0000000000000077","article-title":"Tomographic parameters for the detection of keratoconus: suggestions for screening and treatment parameters","volume":"40","author":"Belin","year":"2014","journal-title":"Eye Contact Lens"},{"issue":"9","key":"bib4","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.1016\/S0161-6420(02)01121-1","article-title":"Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery","volume":"109","author":"Rao","year":"2002","journal-title":"Ophthalmology"},{"issue":"5","key":"bib5","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1016\/j.jcrs.2007.12.036","article-title":"Comparison of and correlation between anterior and posterior corneal elevation maps in normal eyes and keratoconus-suspect eyes","volume":"34","author":"Schlegel","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"bib6","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1111\/cxo.2004.87.issue-2","article-title":"Can true monocular keratoconus occur?","volume":"87","author":"Mahon","year":"2004","journal-title":"Clin Exp Optom"},{"issue":"4","key":"bib7","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/0039-6257(84)90094-8","article-title":"Keratoconus and related noninflammatory corneal thinning disorders","volume":"28","author":"Krachmer","year":"1984","journal-title":"Surv Ophthalmol"},{"issue":"3","key":"bib8","doi-asserted-by":"crossref","first-page":"350","DOI":"10.3928\/1081-597X-20010501-09","article-title":"Complications of laser in situ keratomileusis: etiology, prevention, and treatment","volume":"17","author":"Ambrosio","year":"2001","journal-title":"J Refract Surg"},{"issue":"9","key":"bib9","doi-asserted-by":"publisher","first-page":"1530","DOI":"10.1016\/j.jcrs.2007.04.043","article-title":"Analysis of ectasia after laser in situ keratomileusis: risk factors","volume":"33","author":"Binder","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"bib10","doi-asserted-by":"publisher","first-page":"2010","DOI":"10.1016\/j.jcrs.2008.08.035","article-title":"Risk factors for ectasia after LASIK","volume":"34","author":"Binder","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"bib11","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.ajo.2007.12.033","article-title":"Validation of the Ectasia Risk Score System for preoperative laser in situ keratomileusis screening","volume":"145","author":"Randleman","year":"2008","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"bib12","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ophtha.2007.03.073","article-title":"Risk assessment for ectasia after corneal refractive surgery","volume":"115","author":"Randleman","year":"2008","journal-title":"Ophthalmology"},{"issue":"10","key":"bib13","doi-asserted-by":"publisher","first-page":"7731","DOI":"10.1167\/iovs.10-7093","article-title":"A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR","volume":"52","author":"McAlinden","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"7","key":"bib14","first-page":"1327","article-title":"Neural network classification of corneal topography. Preliminary demonstration","volume":"36","author":"Maeda","year":"1995","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"11","key":"bib15","first-page":"2290","article-title":"Current keratoconus detection methods compared with a neural network approach","volume":"38","author":"Smolek","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"3","key":"bib16","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/S1532-0464(02)00513-0","article-title":"Neural network-based system for early keratoconus detection from corneal topography","volume":"35","author":"Accardo","year":"2002","journal-title":"J Biomed Inf"},{"issue":"12","key":"bib17","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1590\/S1807-59322010001200002","article-title":"Evaluation of machine learning classifiers in keratoconus detection from Orbscan II examinations","volume":"65","author":"Souza","year":"2010","journal-title":"Clinics (Sao Paulo)"},{"issue":"11","key":"bib18","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1016\/j.ophtha.2012.06.005","article-title":"Use of a support vector machine for keratoconus and subclinical keratoconus detection by topographic and tomographic data","volume":"119","author":"Arbelaez","year":"2012","journal-title":"Ophthalmology"},{"issue":"2","key":"bib19","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.ajo.2013.03.034","article-title":"Detection of subclinical keratoconus using an automated decision tree classification","volume":"156","author":"Smadja","year":"2013","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"bib20","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.jcrs.2015.09.020","article-title":"Accuracy of machine learning classifiers using bilateral data from a Scheimpflug camera for identifying eyes with preclinical signs of keratoconus","volume":"42","author":"Kov\u00e1cs","year":"2016","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"bib21","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1097\/ICO.0000000000000834","article-title":"Evaluation of a machine-learning classifier for keratoconus detection based on Scheimpflug tomography","volume":"35","author":"Ruiz Hidalgo","year":"2016","journal-title":"Cornea"},{"issue":"6","key":"bib22","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1097\/ICO.0000000000001194","article-title":"Validation of an objective keratoconus detection system implemented in a Scheimpflug tomographer and comparison with other methods","volume":"36","author":"Ruiz Hidalgo","year":"2017","journal-title":"Cornea"},{"issue":"11","key":"bib23","doi-asserted-by":"publisher","first-page":"e0205998","DOI":"10.1371\/journal.pone.0205998","article-title":"Keratoconus severity identification using unsupervised machine learning","volume":"13","author":"Yousefi","year":"2018","journal-title":"PLoS One"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.compbiomed.2019.04.024","article-title":"Computer aided diagnosis for suspect keratoconus detection","volume":"109","author":"Issarti","year":"2019","journal-title":"Comput Biol Med"},{"issue":"7553","key":"bib25","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1038\/nature14539","article-title":"Deep learning","volume":"521","author":"LeCun","year":"2015","journal-title":"Nature"},{"issue":"2","key":"bib27","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1364\/BOE.10.000622","article-title":"CorneaNet: fast segmentation of cornea OCT scans of healthy and keratoconic eyes using deep learning","volume":"10","author":"Dos Santos","year":"2019","journal-title":"Biomed Opt Express"},{"issue":"9","key":"bib28","doi-asserted-by":"publisher","first-page":"e031313","DOI":"10.1136\/bmjopen-2019-031313","article-title":"Keratoconus detection using deep learning of colour-coded maps with anterior segment optical coherence tomography: a diagnostic accuracy study","volume":"9","author":"Kamiya","year":"2019","journal-title":"BMJ Open"},{"issue":"9","key":"bib29","doi-asserted-by":"publisher","first-page":"2352","DOI":"10.1162\/neco_a_00990","article-title":"Deep convolutional neural networks for image classification: a comprehensive review","volume":"29","author":"Rawat","year":"2017","journal-title":"Neural Comput"},{"key":"bib35","first-page":"2825","article-title":"Scikit-learn: machine learning in Python","volume":"12","author":"Pedregosa","year":"2011","journal-title":"J Mach Learn Res"},{"issue":"2","key":"bib36","doi-asserted-by":"publisher","first-page":"38","DOI":"10.3390\/diagnostics9020038","article-title":"Visual interpretation of convolutional neural network predictions in classifying medical image modalities","volume":"9","author":"Kim","year":"2019","journal-title":"Diagnostics (Basel)"},{"key":"bib39","first-page":"69","article-title":"Appropriate number and allocation of ReLUs in convolutional neural networks","volume":"1","author":"Romanuke","year":"2017","journal-title":"Res Bull NTUU"},{"key":"bib40","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s10479-005-5724-z","article-title":"A tutorial on the cross-entropy method","volume":"134","author":"de Boer","year":"2005","journal-title":"Ann Oper Res"},{"issue":"3","key":"bib41","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/ICO.0B013E31823D1EE0","article-title":"Correlation of corneal elevation with severity of keratoconus by means of anterior and posterior topographic analysis","volume":"31","author":"Ishii","year":"2012","journal-title":"Cornea"},{"issue":"2","key":"bib42","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1148\/radiol.2018181422","article-title":"Assessment of convolutional neural networks for automated classification of chest radiographs","volume":"290","author":"Dunnmon","year":"2019","journal-title":"Radiology"},{"issue":"3","key":"bib43","first-page":"177","article-title":"Pentacam corneal tomography for screening of refractive surgery candidates: a review of the literature, part I","volume":"8","author":"Motlagh","year":"2019","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"key":"bib26","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1109\/CVPR.2009.5206848","article-title":"ImageNet: a large-scale hierarchical image database","volume-title":"2009 IEEE Conference on Computer Vision and Pattern Recognition","author":"Deng","year":"2009"},{"key":"bib30","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1109\/ICECA.2018.8474802","article-title":"Transfer learning for image classification","volume-title":"2018 Second International Conference on Electronics, Communication and Aerospace Technology (ICECA)","author":"Shaha","year":"2018"},{"key":"bib31","volume-title":"Deep Learning","author":"Goodfellow","year":"2016"},{"key":"bib32","first-page":"265","article-title":"Tensorflow: a system for large-scale machine learning","volume-title":"12th USENIX Symposium on Operating Systems Design and Implementation (OSDI \u201916)","author":"Abadi","year":"2016"},{"key":"bib33","article-title":"A new method to visualize deep neural networks","author":"Zintgraf"},{"key":"bib34","article-title":"Adam: a method for stochastic optimization","author":"Kingma"},{"key":"bib37","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1109\/CVPR.2015.7298668","article-title":"Is object localization for free? \u2013 Weakly-supervised learning with convolutional neural networks","volume-title":"2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR)","author":"Oquab","year":"2015"},{"key":"bib38","article-title":"keras: GitHub","author":"Chollet"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2772085","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T00:24:48Z","timestamp":1670372688000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2772085"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,18]]},"references-count":43,"journal-issue":{"issue":"13","published-print":{"date-parts":[[2020,12,1]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.9.13.30","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2020,12,18]]}}}