{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T16:54:50Z","timestamp":1774976090145,"version":"3.50.1"},"reference-count":27,"publisher":"Association for Research in Vision and Ophthalmology (ARVO)","issue":"7","license":[{"start":{"date-parts":[[2020,6,26]],"date-time":"2020-06-26T00:00:00Z","timestamp":1593129600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Trans. Vis. Sci. Tech."],"published-print":{"date-parts":[[2020,6,26]]},"DOI":"10.1167\/tvst.9.7.36","type":"journal-article","created":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T03:13:30Z","timestamp":1593227610000},"page":"36","source":"Crossref","is-referenced-by-count":21,"title":["Keratoconus Detection Based on a Single Scheimpflug Image"],"prefix":"10.1167","volume":"9","author":[{"given":"Alejandra","family":"Consejo","sequence":"first","affiliation":[{"name":"Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jedrzej","family":"Solarski","sequence":"additional","affiliation":[{"name":"Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karol","family":"Karnowski","sequence":"additional","affiliation":[{"name":"Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland"},{"name":"School of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos J","family":"Rozema","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium"},{"name":"Department of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maciej","family":"Wojtkowski","sequence":"additional","affiliation":[{"name":"Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. Robert","family":"Iskander","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wroclaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"27","reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1038\/eye.2013.278","article-title":"The pathogenesis of keratoconus","volume":"28","author":"Davidson","year":"2014","journal-title":"Eye (Lond)"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"91","DOI":"10.17925\/USOR.2017.10.02.91","article-title":"Is keratoconus really rare?","volume":"10","author":"Hafezi","year":"2017","journal-title":"US Ophthal Rev"},{"key":"bib3","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/S0886-3350(01)01321-9","article-title":"Reasons for not performing refractive surgery","volume":"28","author":"Hori-Komai","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"bib4","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1097\/ICO.0000000000001289","article-title":"Refractive surgery: malpractice litigation outcomes","volume":"36","author":"Custer","year":"2017","journal-title":"Cornea"},{"key":"bib5","doi-asserted-by":"publisher","first-page":"5263","DOI":"10.1167\/iovs.14-15055","article-title":"Repeatability and agreement of three Scheimpflug-based imaging systems for measuring anterior segment parameters in keratoconus","volume":"55","author":"Shetty","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1167\/iovs.04-1253","article-title":"Changes in collagen orientation and distribution in keratoconus corneas","volume":"46","author":"Meek","year":"2005","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"4490","DOI":"10.1167\/iovs.14-14450","article-title":"Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy","volume":"55","author":"Scarcelli","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib8","doi-asserted-by":"publisher","first-page":"3651","DOI":"10.1167\/iovs.13-13715","article-title":"Biomechanical responses of healthy and keratoconic corneas measured using a noncontact Scheimpflug-based tonometer","volume":"55","author":"Ali","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib9","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1364\/BOE.8.000162","article-title":"Assessment of corneal properties based on statistical modeling of OCT speckle","volume":"8","author":"Jesus","year":"2017","journal-title":"Biomed Opt Express"},{"key":"bib10","doi-asserted-by":"publisher","first-page":"e0177180","DOI":"10.1371\/journal.pone.0177180","article-title":"Influence of eye biometrics and corneal micro-structure on noncontact tonometry","volume":"12","author":"Jesus","year":"2017","journal-title":"PLoS One"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"5703","DOI":"10.1167\/iovs.17-22864","article-title":"Corneal biomechanical changes and tissue remodeling after SMILE and LASIK","volume":"58","author":"Shetty","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib12","doi-asserted-by":"publisher","first-page":"3197","DOI":"10.1167\/iovs.19-26963","article-title":"Corneal properties of keratoconus based on Scheimpflug light intensity distribution","volume":"60","author":"Consejo","year":"2019","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1097\/00003226-200304000-00004","article-title":"Diurnal variation of corneal sensitivity and thickness","volume":"22","author":"du Toit","year":"2003","journal-title":"Cornea"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1076\/ceyr.16.3.214.15412","article-title":"Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)","volume":"16","author":"Li","year":"1997","journal-title":"Curr Eye Res"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1080\/08820538.2018.1551496","article-title":"Introduction to machine learning for ophthalmologists","volume":"34","author":"Consejo","year":"2019","journal-title":"Semin Ophthalmol"},{"key":"bib16","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1097\/ICO.0b013e31819e34de","article-title":"Evaluation of keratometric, pachymetric, and elevation parameters of keratoconic corneas with Pentacam","volume":"28","author":"Mih\u00e1ltz","year":"2009","journal-title":"Cornea"},{"key":"bib17","doi-asserted-by":"publisher","first-page":"5546","DOI":"10.1167\/iovs.10-5369","article-title":"Topographic and tomographic properties of forme fruste keratoconus corneas","volume":"51","author":"Saad","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.jcrs.2010.12.049","article-title":"Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes","volume":"37","author":"U\u00e7akhan","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"147516","DOI":"10.1155\/2014\/147516","article-title":"Corneal biomechanical assessment using corneal visualization Scheimpflug technology in keratoconic and normal eyes","volume":"2014","author":"Tian","year":"2014","journal-title":"J Ophthalmol"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1016\/j.jbiomech.2015.12.031","article-title":"Detection of subclinical keratoconus through non-contact tonometry and the use of discriminant biomechanical functions","volume":"49","author":"Pe\u00f1a-Garc\u00eda","year":"2016","journal-title":"J Biomech"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"3651","DOI":"10.1167\/iovs.13-13715","article-title":"Biomechanical responses of healthy and keratoconic corneas measured using a noncontact Scheimpflug-based tonometer","volume":"55","author":"Ali","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"2912","DOI":"10.1167\/iovs.09-4304","article-title":"Biomechanical properties of keratoconus suspect eyes","volume":"51","author":"Saad","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.jcrs.2018.10.030","article-title":"Accuracy of Scheimpflug-derived corneal biomechanical and tomographic indices for detecting subclinical and mild keratectasia in a South Asian population","volume":"45","author":"Kataria","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1097\/ICO.0000000000000834","article-title":"Evaluation of a machine-learning classifier for keratoconus detection based on Scheimpflug tomography","volume":"35","author":"Hidalgo","year":"2016","journal-title":"Cornea"},{"key":"bib25","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.compbiomed.2019.04.024","article-title":"Computer aided diagnosis for suspect keratoconus detection","volume":"109","author":"Issarti","year":"2019","journal-title":"Comput Biol Med"},{"key":"bib26","doi-asserted-by":"publisher","first-page":"103809","DOI":"10.1016\/j.compbiomed.2020.103809","article-title":"Logistic index for keratoconus detection and severity scoring (Logik)","volume":"16","author":"Issarti","year":"2020","journal-title":"Comput Biol Med"},{"key":"bib27","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1016\/j.ultrasmedbio.2005.04.020","article-title":"Monitoring structural changes in cells with high-frequency ultrasound signal statistics","volume":"31","author":"Tunis","year":"2005","journal-title":"Ultrasound Med Biol"}],"container-title":["Translational Vision Science &amp; Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2770210","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,22]],"date-time":"2021-03-22T00:04:24Z","timestamp":1616371464000},"score":1,"resource":{"primary":{"URL":"https:\/\/tvst.arvojournals.org\/article.aspx?articleid=2770210"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,26]]},"references-count":27,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2020,6,3]]}},"URL":"https:\/\/doi.org\/10.1167\/tvst.9.7.36","relation":{},"ISSN":["2164-2591"],"issn-type":[{"value":"2164-2591","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6,26]]}}}